After examination of the designed high voltage power supply system of the BESⅢ drift chamber in the beam test of the full length prototype of drift chamber, a full system covering all the channels of high voltage was installed. The system's training and the high voltage value adjustment were carried out in the cosmic ray test of the BESⅢ drift chamber. The cosmic ray test for the full system and its final installation on the BESⅢ drift chamber were reported. The full system of high voltage power supply works stably and reliably. 相似文献
3.
4.
5.
In this paper, the limitations of the common method measuring intrinsic spatial resolution of the GEM imaging detector are presented. Through theoretical analysis and experimental verification, we have improved the common method to avoid these limitations. Using these improved methods, a more precise measurement of intrinsic spatial resolutions are obtained. 相似文献
6.
The design and performance of a Micromegas with a resistive anode are presented in this paper. A thin resistive sheet with volume resistivity of 1012 Ω·m cm is glued onto the readout electrode surface and its performance is investigated by using a 55Fe X-ray radioactive source in the operation gas of argon and isobutene mixtures (Ar/Iso=95/5). The gas gain at different mesh high voltage, counting rate and working time are given. Energy spectra at different working voltages are measured and the results are discussed. We have oberved that a Micromegas with a resistive anode can be operated at higer gain than a standard Micromegas without sparks. 相似文献
7.
A one-dimensional single-wire chamber was developed to provide high position resolution for powder diffraction experiments with synchrotron radiation. A diffraction test using the sample of SiO2 has been accomplished at 1W2B laboratory of Beijing Synchrotron Radiation Source. The data of the beam test were analyzed and some diffraction angles were obtained. The experimental results were in good agreement with standard data from ICDD powder diffraction file. The precision of diffraction angles was 1% to 4.7%. Most of the relative errors between measured values of diffraction angles and existing data were less than 1%. As for the detector, the best position resolution in the test was 138 μm (σ value) with an X-ray tube. Finally, discussions of the results were given. The major factor that affected the precision of measurement was deviation from the flat structure of the detector. The effect was analyzed and the conclusion was reached that it would be the optimal measurement scheme when the distance between the powder sample and detector was from 400 mm to 600 mm. 相似文献
8.
9.
10.