全文获取类型
收费全文 | 127篇 |
免费 | 1篇 |
专业分类
化学 | 108篇 |
力学 | 2篇 |
数学 | 3篇 |
物理学 | 15篇 |
出版年
2024年 | 2篇 |
2021年 | 5篇 |
2020年 | 3篇 |
2019年 | 6篇 |
2017年 | 1篇 |
2015年 | 4篇 |
2013年 | 4篇 |
2012年 | 3篇 |
2011年 | 12篇 |
2010年 | 4篇 |
2009年 | 4篇 |
2008年 | 8篇 |
2007年 | 15篇 |
2006年 | 12篇 |
2005年 | 4篇 |
2004年 | 2篇 |
2003年 | 8篇 |
2002年 | 7篇 |
2001年 | 3篇 |
2000年 | 4篇 |
1999年 | 1篇 |
1998年 | 2篇 |
1996年 | 2篇 |
1994年 | 1篇 |
1993年 | 2篇 |
1992年 | 1篇 |
1991年 | 2篇 |
1990年 | 1篇 |
1989年 | 1篇 |
1985年 | 2篇 |
1975年 | 1篇 |
1968年 | 1篇 |
排序方式: 共有128条查询结果,搜索用时 31 毫秒
1.
Summary We present an approximation method of a space-homogeneous transport equation which we prove is convergent. The method is very promising for numerical computation. Comparison of a numerical computation with an exact solution is given for the Master equation. 相似文献
2.
CR-39 is a polycarbonate widely used as SSNTD for recording nuclear charged particles and in other applications. Latent ion tracks produced in the polymers due to the damage produced by the passage of Swift Heavy Ions contain amorphous material with highest degree of disorder, changing the free volume properties which have strong correlation with the macroscopic properties of the material. Positron annihilation lifetime spectroscopy (PALS) provides direct information about the dimension, content and hole size distribution of free volume in polymers. The effect of irradiation of 40Ar (14.9 MeV/n) ions on CR-39 polycarbonate by Positron Annihilation Lifetime Spectroscopy (PALS) is reported here. PALS provides a non-destructive and non-interfering probe, having high detection efficiency for free volume hole properties. From o-Ps lifetime mean free volume hole radius and average free volume of the micro-voids have been calculated. PAL measurement shows an increase in free volume on irradiation. 相似文献
3.
4.
Uranium(VI and IV) and thorium(IV) give cathodic indentations in supporting electrolytes prepared from 0.1M perchloric acid, 0.5 M ammonium thiocyanate and 5·10-3M cupferron (solution A) or from 0.1 M succinic-succinate buffer pH 4, 0.1 M sodium chloride, 10-3M cupferron and 0.05% gelatine (solution B). The uranium indentation on the dE/dt = f(E) curve (Q=0.75 and 0.73) permits its detection at the 3·10-7M level. The thorium indentation (Q=0.78) permits its detection at the 4·10-7M level in solution B. Methods for the elimination of interfering ions for the uranium determination are described. In the determination of thorium, Ga(III), Fe(III), Ti(IV) and U(VI) interfere. 相似文献
5.
Prados P Matsunaga H Mori T Santa T Fukushima T Homma H Kasai C Imai K 《Biomedical chromatography : BMC》1999,13(1):27-32
Nicardipine, a dihydropyridine type calcium channel blocker, was infused at two flow-rates into spontaneously hypertensive (SH) and control normotensive Wistar-Kyoto (WKY) rats (young, 6-week-old and adult, 23-week-old, n = 5) under pentobarbital anesthesia, to cause hypotension. Mean arterial blood pressure and the concentrations of plasma amino acids and norepinephrine (NE) were measured before infusion and at each step of the infusion. The reduction in blood pressure caused by nicardipine induced a decrease in plasma L-arginine concentration in both young and adult SH rats, this effect being larger in adult rats. There was no significant change in plasma levels of L-arginine in age-matched WKY rats. The concentration of other amino acids did not change in both rat strains. On the contrary, there was an increase in plasma NE concentration in both SH and WKY rats after infusion with nicardipine. Plasma L-arginine concentration showed a good inverse correlation with the logarithm of plasma NE concentration in SH and WKY rats and the correlation was expressed as Y = -alpha log(X) + m (Y, plasma L-arginine concentration (nmol/mL); X, plasma NE concentration (pmol/mL); alpha, a slope; and m, an intercept). alpha, 43.0 and 4.35 for 23-week-old SH and WKY rats, respectively, and 17.0 and 4.0 for 6-week-old SH and WKY rats, respectively. The present data together with previous data suggest a direct noradrenergic stimulation of the synthesis of nitric oxide (NO) from L-arginine. The findings also indicate an impairment of the L-arginine metabolism or pools in SH rats compared with WKY rats. The deficiency of L-arginine increases with the age of SH rats and could be related to the development and maintenance of hypertension due to inefficient production of NO. 相似文献
6.
A fully automated and highly sensitive method with a semi-microcolumn liquid chromatography system for the determination of rat plasma catecholamines (CAs) was developed. Automated on-line extraction of CAs in diluted plasma using a precolumn packed with strong acidic cation exchange resin was coupled with separation of CAs on a semi-microcolumn (250 x 1.5 mm id). fluorogenic derivatization with ethylenediamine and finally postcolumn peroxyoxalate chemiluminescence detection utilizing bis[2-(3,6,9-trioxadecanyloxycarbonyl)-4-nitrophenyl]oxalate (TDPO) and hydrogen peroxide. The detection limits were 0.91, 0.36 and 1.1 fmol for norepinephrine (noradrenaline), epinephrine (adrenaline) and dopamine, respectively, at a signal-to-noise ratio of 3. A good linearity of the calibration curve for each CA was observed in the range of 5.0 to 500 fmol for each CA using N-methyldopamine (N-MeDA) as an internal standard. The RSD for the proposed method (n = 5) were 3.7-9.5% for the intra-day assay and 6.6-10.0% for the inter-day assay. The volume of rat plasma required for the determination of CAs was 10 microliters. 相似文献
7.
Shogo Mitsuhashi Junko Kawai Tomofumi Santa Toshimasa Toyo’oka 《Analytica chimica acta》2006,562(1):36-43
Kynurenic acid (KYNA), an endogenous antagonist of ionotropic glutamate and α7 nicotinic receptors, was fluorometrically determined by column-switching high-performance liquid chromatography (HPLC) with fluorescence detection. The HPLC system consists of two octadecyl silica (ODS) columns, both of which are connected with an anion-exchange column (trapping column). Following sample injection onto the HPLC column, KYNA was separated on the first ODS column with a mobile phase of H2O/acetonitrile (95/5) containing 0.1% acetic acid. The peak fraction of KYNA was trapped on the anion-exchange column by changing the position of a six-port valve and then introduced into the second ODS column. Subsequently, KYNA was detected fluorometrically as a fluorescence complex formed with zinc ion which was pumped constantly. Instrumental limit of detection was approximately 0.16 nM, which corresponded to 8.0 fmol (per 50 μl injection, signal to noise ratio 3), and the limit of quantification was 0.53 nM (signal to noise ratio 10). Intra- and inter-day relative standard deviations were 1.1-3.9% (n = 3) and 3.0-5.3% (n = 3), respectively. The peak of KYNA in rat plasma was clearly detected by the proposed column-switching HPLC system after a facile pretreatment procedure. Intra- and inter-day relative mean errors were −1.6-1.4% (n = 3) and −2.4 to −0.4% (n = 3), respectively, with a satisfactory precision (within 5.0%). A calibration curve for the determination of KYNA showed a good linearity (r2 > 0.999) in the range of 25-200 nM. The KYNA concentrations in the plasma of male Sprague-Dawley rats (8-week-old) were 44 ± 5.5 nM (mean ± S.E., n = 5). In ketamine-treated rats, which are animal models of schizophrenia, the plasma KYNA concentrations were significantly increased compared with those in the control rats (p < 0.05). 相似文献
8.
Fluorogenic and fluorescent labeling reagents having a benzofurazan (2,1,3-benzoxadiazole) skeleton such as 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F), 4-N,N-dimethylaminosulfonyl-7-fluoro-2,1,3-benzoxadiazole (DBD-F), 4-aminosulfonyl-7-fluoro-2,1,3-benzoxadiazole (ABD-F), ammonium 7-fluoro-2,1,3-benzoxadiazole-4-sulfonate (SBD-F), 4-hydrazino-7-nitro-2,1,3-benzoxadiazole (NBD-H), 4-N,N-dimethylaminosulfonyl-7-hydrazino-2,1,3-benzoxadiazole (DBD-H), 4-nitro-7-N-piperazino-2,1,3-benzoxadiazole (NBD-PZ), 4-N,N-dimethylaminosulfonyl-7-N-piperazino-2,1,3-benzoxadiazole (DBD-PZ), 4-(N-chloroformylmethyl-N-methyl)amino-7-N,N-dimethylaminosulfonyl-2,1,3-benzoxadiazole (DBD-COCl) and 7-N,N-dimethylaminosulfonyl-4-(2,1,3-benzoxadiazolyl) isothiocyanate (DBD-NCS) are reviewed in terms of synthetic method, reactivity, fluorescence characteristics, sensitivity and application to analytes. 相似文献
9.
Sensitive, reactive, and hydrophilic fluorogenic reagents for thiols with the benzofurazan skeleton, 4-(N-acetylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (AcABD-F) and 4-(N-trichloroacetylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (TCAcABD-F) have been developed. These reagents reacted with thiols within 10 min at 60 degrees C. AcABD-F and TCAcABD-F themselves do not fluoresce but are strongly fluorescent after the reaction with thiol compounds. The generated derivatives were highly water-soluble, since they dissociated a proton and ionized in the neutral pH region. The derivatives with four biologically important thiol compounds were separated on a reversed-phase HPLC column and detected fluorometrically at 504 nm with excitation at 388 nm. The detection limit attained for homocysteine with AcABD-F was 25 fmol on column (11 nM) (signal-to-noise ratio = 3), and that for glutathione with TCAcABD-F was 45 fmol on column (20 nM). 相似文献
10.
An automated analyzer for vancomycin in rat plasma by column-switching high-performance liquid chromatography (HPLC) with UV detection was developed. The method includes in-line extraction of vancomycin by ion-exchange cartridge column and a separation on a reversed-phase column with UV detection at 215 nm. Plasma samples were diluted by mobile phase solution and directly injected to HPLC. Vancomycin was quantitatively recovered from rat plasma samples. The separation was completed within 15 min. The calibration curve was linear over the range from 0.5 to 100 microg/mL with the detection and quantification limits of 0.5 microg/mL (2.5 ng on column; signal-to-noise ratio = 3). The values of precision in intra- and inter-day assays (n = 3) were less than 1.92 and 3.69%, respectively. This method does not require time-consuming pre-treatment and is suitable for the routine assay of plasma samples. 相似文献