首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   11篇
  免费   2篇
化学   9篇
数学   4篇
  2020年   1篇
  2018年   1篇
  2016年   2篇
  2015年   2篇
  2014年   2篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2009年   2篇
排序方式: 共有13条查询结果,搜索用时 140 毫秒
1.
2.
A novel method for the selective electromembrane extraction (EME) of U6+ prior to fluorometric determination has been proposed. The effect of extraction conditions including supported liquid membrane (SLM) composition, extraction time and extraction voltage were investigated. An SLM composition of 1% di-2-ethyl hexyl phosphonic acid in nitrophenyl octyl ether (NPOE) showed good selectivity, recovery and enrichment factor. The best performance was achieved at an extraction potential of 80 volts and an extraction time of 14 minutes Under the optimized conditions, a linear range from 1 to 1000 ng mL−1 and LOD of 0.1 ng mL−1 were obtained for the determination of U6+. The EME method showed good performance in sample cleanup and the reduction of the interfering effects of Mn2+, Zn2+, Cd2+, Ni2+, Fe3+, Co2+, Cu2+, Cl and PO43− ions during fluorometric determination of uranium in real water samples. The recoveries above 54% and enrichment factors above 64.7 were obtained by the proposed method for real sample analysis.  相似文献   
3.
4.
In this first study performed in noodle samples consumed in Malaysia for the presence of deoxynivalenol (DON), a total of 135 sample of noodles, comprised of instant noodle, yellow alkaline noodle and white salted noodle, were randomly collected from food stores and analyzed for DON using high performance liquid chromatography (HPLC) with a PDA (photodiode array) detector at 218 nm. The objective of this study was to investigate the DON contamination levels in different types of wheat-based noodle consumed in Peninsular Malaysia. An acetonitrile:water (17:83 v/v) mixture was used as a mobile phase and clean-up was accomplished with a Mycosep 225 column. There was a high variation in the DON concentrations in all types of noodle group as well as between brands. Only one sample of instant and yellow alkaline noodle each were contaminated with DON, at concentrations of 1.003 and 1.243 ng/g, respectively. The minimum detectable concentration for the DON was 0.627 ng/g in instant noodle. In the case of white salted noodle, none of the samples contained any detectable amount of DON. The results indicate a low occurrence of DON mycotoxins in commercial noodle products in Malaysia.  相似文献   
5.
6.
Electromembrane extraction (EME) was carried out using a novel instrumentation capable of impedometric monitoring of the system during the extraction. This instrumentation involves a classical two-electrode assembly fed by two time-resolved potential functions, the first for the extraction of analyte and the second for obtaining the impedance information. The impedometric analysis of the system was achieved by Laplace transformation of the current recorded during the extraction. It has been shown that the obtained impedance information can be converted to very useful knowledge about time dependence of double layer capacitance, kinetics of analyte depletion, total permeability of the SLM and the effect of experimental parameters on system behavior. It has also been shown that the impedance analysis is a powerful tool for the estimation of optimum experimental parameters without determination of analyte in the acceptor phase.  相似文献   
7.
Magnetic molecularly imprinted polymers have been synthesized for the selective preconcentration and trace determination of lamotrigine (LTG) in urine and plasma samples. The magnetic nanoparticles were modified by tetraethyl orthosilicate and 3‐methacryloxypropyl trimethoxysilane before imprinting. The magnetic molecularly imprinted polymers were prepared via surface molecular imprinting technique, using Fe3O4 as a magnetic component, LTG as template molecule, methacrylic acid as a functional monomer, ethylene glycol dimethacrylate as a cross‐linker, and 2,2′‐azobisisobutyronitrile as a radical initiator in methanol/acetonitrile (50:50, v/v) as the porogen. The obtained sorbent was characterized using scanning electron microscopy, Fourier‐transform infrared spectroscopy, X‐ray diffraction, and thermal analysis. Separation of the sorbent from the sample solution was simply achieved by applying an external magnetic field. Determination of the extracted drug was performed by high‐performance liquid chromatography with UV detection. Under the optimum extraction conditions, the method detection limits were 0.7 μg/L (based on S/N of 3) for urine samples and 0.5 μg/L for plasma samples. A linear dynamic range of 1–1000 μg/L was obtained for LTF in plasma and urine samples. Finally, the applicability of the proposed method was evaluated by extraction and determination of LTG in urine and plasma samples.  相似文献   
8.
Electromembrane extraction (EME) of model analytes was carried out using a virtually rotating supported liquid membrane (SLM). The virtual (nonmechanical) rotating of the SLM was achieved using a novel electrode assembly including a central electrode immersed inside the lumen of the SLM and five counter electrodes surrounding the SLM. A particular electronic circuit was designed to distribute the potential among five counter electrodes in a rotating pattern. The effect of the experimental parameters on the recovery of the extraction was investigated for verapamil (VPL), trimipramine (TRP), and clomipramine (CLP) as the model analytes and 2‐ethyl hexanol as the SLM solvent. The results showed that the recovery of the extraction is a function of the angular velocity of the virtual rotation. The best results were obtained at an angular velocity of 1.83 RadS?1 (or a rotation frequency of 0.29 Hz).The optimization of the parameters gave higher recoveries up to 50% greater than those of a conventional EME method. The rotating also allowed the extraction to be carried out at shorter time (15 min) and lower voltage (200 V) with respect to the conventional extraction. The model analytes were successfully extracted from wastewater and human urine samples with recoveries ranging from 38 to 85%. The RSD of the determinations was in the range of 12.6 to 14.8%.  相似文献   
9.
The distribution of electric field vectors was first calculated for electromembrane extraction (EME) systems in classical and cylindrical electrode geometries. The results showed that supported liquid membrane (SLM) has a general field amplifying effect due to its lower dielectric constant in comparison with aqueous donor/acceptor solutions. The calculated norms of the electric field vector showed that a DC voltage of 50 V can create huge electric field strengths up to 64 kV m−1 and 111 kV m−1 in classical and cylindrical geometries respectively. In both cases, the electric field strength reached its peak value on the inner wall of the SLM. In the case of classical geometry, the field strength was a function of the polar position of the SLM whereas the field strength in cylindrical geometry was angularly uniform. In order to investigate the effect of the electrode geometry on the performance of real EME systems, the analysis was carried out in three different geometries including classical, helical and cylindrical arrangements using naproxen and sodium diclofenac as the model analytes. Despite higher field strength and extended cross sectional area, the helical and cylindrical geometries gave lower recoveries with respect to the classical EME. The observed decline of the signal was proved to be against the relations governing migration and diffusion processes, which means that a third driving force is involved in EME. The third driving force is the interaction between the radially inhomogeneous electric field and the analyte in its neutral form.  相似文献   
10.
In order to understand the limitations of electromebrane extraction procedure better, a simple equivalent circuit has been proposed for a supported liquid membrane consisting of a resistor and a low leakage capacitor in series. To verify the equivalent circuit, it was subjected to a simulated periodical polarity changing potential and the resulting time variation of the current was compared with that of a real electromembrane extraction system. The results showed a good agreement between the simulated current patterns and those of the real ones. In order to investigate the impact of various limiting factors, the corresponding values of the equivalent circuit were estimated for a real electromembrane extraction system and were attributed to the physical parameters of the extraction system. A dual charge transfer mechanism was proposed for electromembrane extraction by combining general migration equation and fundamental aspects derived from the simulation. Dual mechanism comprises a current dependent contribution of analyte in total current and could support the possibility of an improvement in performance of an electromembrane extraction by application of an asymmetric polarity changing potential. The optimization of frequency and duty cycle of the asymmetric polarity exchanging potential resulted in a higher recovery (2.17 times greater) in comparison with the conventional electromebrane extraction. The simulation also provided more quantitative approaches toward the investigation of the mechanism of extraction and contribution of different limiting factors in electromembrane extraction. Results showed that the buildup of the double layer is the main limiting factor and the Joule heating has lesser impact on the performance of an electromebrane extraction system.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号