首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   26篇
  免费   0篇
  国内免费   1篇
化学   23篇
数学   1篇
物理学   3篇
  2022年   1篇
  2021年   1篇
  2019年   1篇
  2018年   2篇
  2016年   2篇
  2015年   2篇
  2014年   2篇
  2013年   2篇
  2012年   1篇
  2011年   4篇
  2010年   2篇
  2009年   2篇
  2008年   1篇
  2007年   4篇
排序方式: 共有27条查询结果,搜索用时 15 毫秒
1.
A facile protocol for the one-pot, multicomponent reaction of indole, 4-hydroxycoumarin, and aromatic aldehydes was developed using copper octoate as an inexpensive, commercially available, and efficient catalyst. This highly selective reaction eliminates the formation of homodimeric by-products (bisindoles and biscoumarins) and selectively results in the formation of heterodimeric adducts containing both indole and coumarin heterocycles.  相似文献   
2.
A poly(vinyl chloride) (PVC) membrane sensor for holmium ions was fabricated based on N‐[(Z)‐1‐(2‐thienyl)‐ methylidene]‐N‐[4‐(4‐{[(Z)‐1‐(2‐thienyl)methylidene]amino} phenoxy)phenyl] amine (TPA) as a new ion carrier, acetophenon (AP) as plasticizing solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. The electrode shows a good selectivity towards Ho3+ ions respect to other inorganic cations, including alkali, alkaline earth, transition and heavy metal ions. The constructed sensor displays a Nernstian behavior (19.5±0.3 mV/decade) over the concentration range of 1.0×10−6 to 1.0×10−2 mol·L−1 with the detection limit of the electrode being 4.6×10−7 mol·L−1 and very short response time (ca. 5 s). It has a useful working pH range of 3.2–9.8 for at least 8 weeks. The electrode was successfully applied as an indicator electrode for the potentiometric titration of a Ho3+ solution with EDTA and holmium determination in some alloys. The proposed sensor accuracy was studied by the determination of Ho3+ in mixtures of three different ions.  相似文献   
3.
The increase use of ion sensors in the fields of environmental, agricultural, and medical analysis is stimulating analytical chemists to develop new sensors for fast, accurate, reproducible, and selective determination of various ions. In this study a new samarium membrane sensor was constructed and for the first time, it was applied as a probe in indirect determination of hyoscine, homatropine, and tramadol drugs in their pharmaceutical formulation. The proposed membrane sensor was constructed based on a membrane containing 2% sodium tetraphenyl borate (NaTPB) as an anionic additive, 63% dibutyl phthalate (DBP) as solvent mediator, 5% ionophore, and 30% poly(vinyl chloride) (PVC). The proposed Sm(III) electrode exhibits a Nernstian response of 19.35±0.2 mV per decade of samarium concentration, and has a lower detection limit of 1.0×10?7 M. The linear range of the sensors was 1.0×10?7–1.0×10?1 M. It works well in the pH range of 3.0–8.0.  相似文献   
4.
A novel and simple fluorescence enhancement method for selective pyrophosphate(PPi) sensing was proposed based on a 1:1 metal complex formation between bis(8-hydroxy quinoline-5-solphonat) chloride aluminum(III) (Al(QS)2Cl), (L) and PPi in aqueous solution. The linear response range covers a concentration range of 1.6 × 10−7 to 1.0 × 10−5 mol/L of PPi and the detection limit of 2.3 × 10−8 mol/L. The association constant of L-PPi complex was calculated 2.6 × 105 L/mol. L was found to show selectively and sensitively fluorescence enhancement toward PPi over than I3-, NO3-, CN, CO32−, Br, Cl, F, H2PO4 and SO42−, which was attributed to higher stability of inorganic complex between pyrophosphate and L.  相似文献   
5.
Room temperature ionic liquids (RTILs), 1‐n‐butyl‐3‐methylimidazolium tetrafluoroborate, [bmim]BF4, and multiwalled carbon nanotubes (MWCNTs) were used for improvement of a praseodymium carbon paste ion selective sensor response. [bmim]BF4 can be a better binder than mineral oils. MWCNTs have a good conductivity which helps the transduction of the signal in carbon paste electrode. The characteristics of these electrodes as potentiometric sensors were evaluated and compared with PVC membrane sensor. The results indicate that potentiometric sensor constructed with ionic liquid shows an increase in performance in terms of Nernstian slope, selectivity, response time, and response stability compared to Pr(III) PVC membrane sensor.  相似文献   
6.
7.
Dicloran pesticide is used to inhibit the fungal spore germination for different crops. Because of the increasing application of pesticides, reliable and accurate analytical methods are necessary. The aim of this work is designing the highly selective sensor to determine the dicloran in biological and environmental samples. Multi-walls carbon nanotubes and a molecularly imprinted polymer (MIP) were used as modifiers in the sensor composition. A dicloran MIP and a nonimprinted polymer (NIP) were synthesized and applied in the carbon paste electrode. After the optimization of electrode composition, it was used to determine the concentration of analyte. Parameters affecting the sensor response were optimized, such as sample pH, electrolyte concentration and its pH, and the instrumental parameters of square wave voltammetry. The MIP-CP electrode showed very high recognition ability in comparison with NIP-CP. The obtained linear range was 1 × 10?6 to 1 × 10?9 mol L?1. The detection limit was 4.8 × 10?10 mol L?1. This sensor was used to determine the dicloran in real samples (human urine, tap and river water samples) without special sample preparation before analysis. All important parameters were optimized, improving the sensor response considerably.  相似文献   
8.
A novel fluorescence nano-chemosensor for Cr2O72− anion has been developed by assembly of fluorescent aluminum complex of 8-hydroxyquinoline (AlQx) within the channels of modified SBA-15. SBA-SPS-AlQx shows a fluorescence emission at 486 nm. The observed remarkable fluorescence of SBA-SPS-AlQx quenches in presence of Cr2O72− anion. The results showed that this fluorescent nano-material can be a useful chemo-sensor for determination of dichromate anions in aqueous solutions. The linear detecting range of fluorescent nano-chemosensor for Cr2O72− anion was 0.16–2.9 μmol L−1. The lowest limit of detection (LDL) was also found to be 0.2 ng mL−1 in aqueous solutions. SBA-SPS-AlQx showed selectively and sensitively fluorescent quenching response toward Cr2O72− ion in comparison with I3, NO3, CN, CO32−, Br, Cl, F, H2PO4 and SO42− ions, which was because of the higher stability of its inorganic complex with dichromate ion.  相似文献   
9.
A new Lu3+ sensitive fluorescent chemosensor is designed using 8-hydroxyquinoline functionalized mesoporous silica with highly ordered structure (LUS-SPS-Q). The characterization of LUS-SPS-Q showed that the organized structure has been preserved after the post grafting procedure. The synthesized material showed a selective interaction with Lu3+ ion, most probably due to the presence of the fluorophore moiety at its surface. The emission intensity of the Lu3+-bound mesoporous material increases with an increase in concentrations of Lu3+ ion. Addition of other mono-, di-, trivalent ions resulted in insignificant change in the fluorescent intensity. The enhancement of fluorescence is attributed to the strong covalent binding of Lu3+ ion. The linear response range of Lu3+ chemo-sensor was from 1.6 × 10−7 to 1.0 × 10−5 mol L−1. The Limit of detection obtained was 8.2 × 10−8 mol L−1 and the pH range which the proposed chemo-sensor can be applied was 3.3–8.3.  相似文献   
10.
A new fluorogenic method for selective and sensitive determination of beryllium using 2,6-diphenyl-4-benzo-9-crown-3-pyrane (DBCP) was developed. The proposed fluorescent probe undergoes fluorescent emission intensity enhancement upon binding to beryllium ions in MeOH/H(2)O (70:30, v/v) solution. The fluorescence enhancement of DBCP is attributed to a 1:1 complex formation between DBCP and Be(2+) ion, which has been utilized as the basis for selective detection of Be(2+) ion. With the optimum condition described, the fluorescence enhancement at 531 nm was linear to the concentration of beryllium in the range of 1.6×10(-8)-1.6×10(-7) M and a detection limit of 1.5×10(-9) M. The fluorescent probe exhibits high selectivity for Be(2+) ion over the other common mono, di- and trivalent cations.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号