Journal of Fluorescence - We have constructed a novel fluorescein-based fluorescent chemosensor, FL-In, functionalised with an indole moiety and capable of sensing by both the optical... 相似文献
A simple sensitive and selective liquid chromatographic–tandem mass spectrometric method was developed and validated for the quantification of azithromycin in human plasma. Roxithromycin was used as the internal standard. The chromatographic separation was performed on a SunFire C18, 50 mm × 2.1, 3.5 μm column at 30 °C with mobile phase consisted of 1.54 g ammonium acetate, 250 mL water, 570 mL acetonitrile, 180 mL methanol and 0.6 mL glacial acetic acid. Flow rate was 0.2 mL min−1. The work-up procedure involved a liquid–liquid extraction of the compounds. Mass spectrometric data were acquired in single ion monitoring. MRM mode of the ions 749.58 > 591.6 and 837.64 > 158.2 for azithromycin and roxithromycin, respectively. The method was validated in the concentration range of 2–1,000 ng mL−1. Absolute recovery of azithromycin was 81.97%. Retention time for azithromycin was 0.9 and 1.1 min for roxithromycin. The run time was 2 min. This method was found suitable to analyse human plasma samples for application in pharmacokinetic, pharmacodynamic, bioavailability/bioequivalance studies.
Electron ionization (EI) mass spectra of 46 compounds from several different compound classes were measured. Their molecular ion abundances were compared as obtained with 70‐eV EI, with low eV EI (such as 14 eV), and with EI mass spectra of vibrationally cold molecules in supersonic molecular beams (Cold EI). We further compared these mass spectra in their National Institute of Standards and Technology (NIST) library identification probabilities. We found that
Low eV EI is not a soft ionization method, and it has little or no influence on the molecular ion relative abundances for large molecules and those with weak or no molecular ions.
Low eV EI for compounds with abundant or dominant molecular ions in their 70 eV mass spectra results in the reduction of low mass fragment ions abundances thereby reducing their NIST library identification probabilities thus rarely justifies its use in real‐world applications.
Cold EI significantly enhances the relative abundance of the molecular ions particularly for large compounds; yet, it retains the low mass fragment ions; hence, Cold EI mass spectra can be effectively identified by the NIST library.
Different standard EI ion sources provide different 70 eV EI mass spectra. Among the Agilent technologies ion sources, the “Extractor” exhibits relatively abundant molecular ions compared with the “Inert” ion source, while the “High efficiency source” (HES) provides mass spectra with depleted molecular ions compared with the “Inert” ion source or NIST library mass spectra.
These conclusions are demonstrated and supported by experimental data in nine figures and two tables. 相似文献
GaxIn1–xAsyP1–y alloys lattice matched to InP substrates are currently used to fabricate optoelectronic and integrated optics devices. To achieve devices with high performances and high fabrication yield, the uniformity and reproducibility of the GaxIn1–xAsyP1–y epitaxial layers (composition, thickness, doping, etc.) have become key parameters. These problems have been addressed in the frame of ESPRIT project 2518 and are presented in this paper. Several aspects have been considered starting from the optimization of InP substrates, the MOVPE growth of uniform GalnAsP layers, the material characterization to the validation of material uniformity on passive optical waveguides. Both scanning photoluminescence analysis and waveguide losses measurements performed on 2 inch wafers with a high lateral resolution have shown that high quality uniform GalnAsP layers can be obtained reproducibly on 2 InP substrates using a commercially available LP-MOCVD growth process. In particular, more than 60% of 36 mm long, 3m wide and 100m spaced rib waveguides exhibit losses below 0.8dBcm–1. 相似文献
The aim of this Letter is to show that, the Nusselt number sign might be changed without changing of heat transfer direction at the wall of channels, even for flows without viscous dissipation. 相似文献
The inhibition efficiency of 2-Pyrrolidin-1-yl-1,3-thiazole-5-carboxylic acid (PTCA) against mild steel (MS) corrosion was investigated in acidic solution by using quantum chemical calculations based on Density Functional Theory (DFT) method and electrochemical measurements. The electrochemical impedance spectroscopy (EIS), potentiodynamic, potential zero charge (pzc) analysis and electrochemical noise (EN) measurements at various concentrations (from 0.1 to 10 mM) and immersion times were utilized in experimental part. The surface analysis was achieved scanning electron microscope (SEM) and contact angle measurements in the absence and presence of 10 mM PTCA. According to DFT results, PTCA exhibited 3.737 eV band gap and 8.130 Debye dipole moment which were a signal of potentially convenient corrosion inhibitor properties. PTCA has a remarkable corrosion inhibition capability to mild steel, which inhibited both anodic and cathodic corrosion rates, relying on it's physically adsorption on the metal solution interface and protection ability was increased with increasing PTCA concentration. The obtained adsorption equilibrium constant was 11.11 × 103 M-1 and calculated standard free energy of adsorption was ?33.03 kJ mol?1. The determined activation energy values were 55.58 kJ mol?1 and 96.86 kJ mol?1 in 0.5 M HCl in the absence and presence of 10 mM PTCA, respectively. PTCA demonstrated a strong inhibition efficiency of 98.3%, after 168 h immersion, according to the EIS results. As a consequently, we recommend that PTCA is a convenient inhibitor in 0.1 M HCl for mild steel protection against corrosion. 相似文献
This paper demonstrates a Schiff base i. e. 5-(diethylamino)-2-((2,6-diethylphenylimino)methyl)phenol (5-DDMP) that was sensed by DNA biosensor. dsDNA was immobilized onto GCE modified with functionalized multi-walled carbon nanotubes to prepare a biosensor. The efficiency of dsDNA biosensor was determined and binding of 5-DDMP with dsDNA was searched by UV-vis spectrophotometry and differential pulse voltammetry. Molecular docking simulations between 5-DDMP and dsDNA were explored and as a result, a hydrogen bond and a π-π contact were observed between 5-DDMP and deoxyguanosine base (dG22) of the strand B, deoxyadenosine base (dA5) of the strand A, respectively. These studies could be useful for new anticancer drug design and development. 相似文献
In this study, the effects of ultrasound on ozone treatment processes for bleaching cotton fabrics were investigated and compared with the conventional hydrogen peroxide bleaching process (60 °C over 90 min). Two ultrasonic + ozone treatments of cotton fabric samples were carried out: (1) ozone in an ultrasonic homogenizer (UH) and (2) ozone in an ultrasonic bath. Ozone dosages, temperature and time variations were determined with both ozone-ultrasonic bleaching processes. Whiteness, yellowness, weight, tensile strength properties, FTIR (ATR) spectra and visual appearance, via scanning electron microscopy of treated cotton fabrics as well as chemical oxygen demand (COD) of bleaching effluents, were investigated. It was concluded that the ozone + UH process, conducted for 30 min at 30 °C, produced closely equivalent values of cotton fabric whiteness and yellowness to the classic peroxide bleaching process, with slightly less weight loss, dramatically less COD in the process effluent (29 mg/l for ozone-UH vs. 4,316 mg/l for classical peroxide treatment), and without causing any adverse and/or detrimental effects on loss of fabric strength or elongation of the cotton fabrics. The ozone-UH process also leads to time and energy savings with much less environmental impact. Consequently, the combination of ozonation plus UH carried out at 30 °C over 30 min can be used successfully for cotton bleaching instead of the classic hydrogen peroxide bleaching process. 相似文献
This paper consists of two parts. In the first part, the strain dependence of entanglements or constraints acting along the contour of a Gaussian chain is derived. The functional form of the elastic free energy resulting from constraints along the chain contour is identical to that obtained in the Flory constrained junction model. In the second part, the effective number of constraints acting along the contour of a chain is discussed. The choice of this number results from postulates imposed by various authors and cannot be derived by rigorous theory. The paper compares the predictions based on these assumptions with experimental data from model networks. 相似文献