首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
化学   3篇
数学   2篇
物理学   1篇
  2020年   1篇
  2018年   1篇
  2013年   1篇
  1996年   1篇
  1995年   2篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
The computer program sparc was used to calculate the pK(a) values of some important pharmaceutical substances. The sparc models proved to be suitable for estimating the pK(a) values of beta-adrenergic blocking agents and benzodiazepine drugs. Ionization macroconstants, microconstants, zwitterionic equilibria, speciation curves as a function of the pH and the isoelectric points of a semi-essential amino acid, arginine, and an anti-inflammatory, niflumic acid, were calculated.  相似文献   
2.
Aluminum and copper ions are selectively estimated spectrophotometrically. These ions form colored complexes with spadns which have a maximum absorbance at 580 nm. The complexes formed with both cations are stable and pH dependant; aluminum is favorably complexed at pH 5, while copper is complexed at pH 7.The percentage recoveries were found to be 99.69 ± 0.75 and 99.32 ± 0.6 with a minimum detection limit of 0.08 and 0.23 g ml–1 for aluminum and copper ions respectively. There is insignificant interference from the 10-fold concentrations of other metal ions under the proposed reaction conditions.  相似文献   
3.
Abstract

A sensitive, rapid, accurate and precise procedure for the microdetermination of heparin sodium in bulk, in injection and in blood serum. The procedure was built around the fact that heparin possesses many active binding sites; carboxylic, hydroxylic, amino and sulphonated groups, which are strongly bound to Eu3+ ions. Such binding enhances the europium emission at 616 nm which is a forbidden transition. The emission of europium at 592 nm comes from a non hypersensitive transition and is not affected by the ligand which is bound to europium ions. The intensity ratio R, defined as I592/I616 was used to determine the amount of free and bound europium ions. There is a linear relationship between bound europium ions and heparin sodium within the concentration range 1–12 ug. mL?1 (0.07–0.84 USP. IN). Reaction conditions were studied and percentage recoveries was 99.77 ± 1.68. The relative stability of the complex was 1.2E5 and the correlation coefficient was 0.99923. Heparin was isolated from serum using ECTEOLA-cellulose and Sephadex G25 columns. The method shows good agreement with an anilinonaphthalene-1-sulfonate (ANS) and protamine fluorometric method.  相似文献   
4.
Monatshefte für Mathematik - This paper concerns the spectrum and the fine spectrum of the discrete generalized Cesàro operator $$C_{t}$$ , where $$0\le t<1$$ , on Banach sequence...  相似文献   
5.
6.
The application of probe ion fluorimetry has succeeded in the microdetermination of six aminoglycoside antibiotics: neomycin, streptomycin, gentamicin, tobramycin, amikacin and kanamycin as sulfate salts in pure form and in some pharmaceutical preparations. The method is based on the reaction of Eu3+ ions with aminoglycosides through amino and hydroxy groups. Such interactions enhance the intensity of the 616 nm fluorescence emission of the Eu3+ ion. The fluorescence at 592 nm comes from a non-hypersensitive transition and is not affected by the ligand which is bound to the probe ions. The intensity ratio R, defined as I592/I616 was used to determine the amount of free and bound europium ions. A linear relationship between bound europium ions and aminoglycoside was found within the concentration ranges 20–100 ppm for neomycin, 5–60 ppm for streptomycin, and 10–70 ppm for gentamicin, tobramycin, amikacin, and kanamycin as sulfate salts. The percentage recoveries ranged from 99.22 to 101.07, with standard deviations ranging from ± 1.5 to ± 4.38. The relative stability constants ranged from 5 × 103 to 2 × 104. The optimum reaction conditions were studied and the results obtained compared favourably with the fluorimetric method using fluorescmine reagent.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号