首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   61篇
  免费   0篇
化学   21篇
力学   11篇
数学   11篇
物理学   18篇
  2022年   1篇
  2020年   2篇
  2019年   5篇
  2018年   1篇
  2017年   1篇
  2016年   1篇
  2015年   5篇
  2014年   5篇
  2013年   3篇
  2012年   8篇
  2011年   5篇
  2010年   2篇
  2009年   5篇
  2008年   4篇
  2007年   4篇
  2006年   2篇
  2005年   1篇
  2004年   1篇
  2003年   2篇
  2000年   2篇
  1999年   1篇
排序方式: 共有61条查询结果,搜索用时 15 毫秒
1.
Extending fixed‐grid time integration schemes for unsteady CFD applications to moving grids, while formally preserving their numerical stability and time accuracy properties, is a nontrivial task. A general computational framework for constructing stability‐preserving ALE extensions of Eulerian multistep time integration schemes can be found in the literature. A complementary framework for designing accuracy‐preserving ALE extensions of such schemes is also available. However, the application of neither of these two computational frameworks to a multistage method such as a Runge–Kutta (RK) scheme is straightforward. Yet, the RK methods are an important family of explicit and implicit schemes for the approximation of solutions of ordinary differential equations in general and a popular one in CFD applications. This paper presents a methodology for filling this gap. It also applies it to the design of ALE extensions of fixed‐grid explicit and implicit second‐order time‐accurate RK (RK2) methods. To this end, it presents the discrete geometric conservation law associated with ALE RK2 schemes and a method for enforcing it. It also proves, in the context of the nonlinear scalar conservation law, that satisfying this discrete geometric conservation law is a necessary and sufficient condition for a proposed ALE extension of an RK2 scheme to preserve on moving grids the nonlinear stability properties of its fixed‐grid counterpart. All theoretical findings reported in this paper are illustrated with the ALE solution of inviscid and viscous unsteady, nonlinear flow problems associated with vibrations of the AGARD Wing 445.6. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   
2.
The study of individual cells with infrared (IR) microspectroscopy often requires living cells to be cultured directly onto a suitable substrate. The surface effect of the specific substrates on the cell growth—viability and associated biochemistry—as well as on the IR analysis—spectral interference and optical artifacts—is all too often ignored. Using the IR beamline, MIRIAM (Diamond Light Source, UK), we show the importance of the substrate used for IR absorption spectroscopy by analyzing two different cell lines cultured on a range of seven optical substrates in both transmission and reflection modes. First, cell viability measurements are made to determine the preferable substrates for normal cell growth. Successively, synchrotron radiation IR microspectroscopy is performed on the two cell lines to determine any genuine biochemically induced changes or optical effect in the spectra due to the different substrates. Multivariate analysis of spectral data is applied on each cell line to visualize the spectral changes. The results confirm the advantage of transmission measurements over reflection due to the absence of a strong optical standing wave artifact which amplifies the absorbance spectrum in the high wavenumber regions with respect to low wavenumbers in the mid-IR range. The transmission spectra reveal interference from a more subtle but significant optical artifact related to the reflection losses of the different substrate materials. This means that, for comparative studies of cell biochemistry by IR microspectroscopy, it is crucial that all samples are measured on the same substrate type.
Figure
Cell separation by PCA due to the refractive index of the substrate used, revealing transmission artifact.  相似文献   
3.
Bee venom (BV) is one of the most remarkable natural products that has been a subject of studies since ancient times. Recent studies have shown that Apis mellifera syriaca venom possesses antibacterial as well as cytotoxic effects on cancer cell lines. The venom contains a variety of bioactive molecules—mainly melittin (MEL) and phospholipase A2 (PLA2), as well as other compounds that are not well characterized. In this work, we continue the biological characterization of A. mellifera syriaca venom by testing its anticoagulant effect on human plasma using the prothrombin time (PT) test, as well as assessing its proteolytic activity. In addition, the cytotoxicity of the crude venom—and of its two main components, MEL and PLA2—was tested on HeLa cancer cell lines for the first time. The results obtained showed the capacity of A. mellifera syriaca venom to increase clotting time, thereby proving its anticoagulant effect. Moreover, the venom did not demonstrate a significant proteolytic activity unless administrated at concentrations ≥ 5 mg/mL. Finally, we showed that crude A. mellifera syriaca venom, along with MEL, exhibit a strong in vitro cytotoxic effect on HeLa cancer cell lines, even at low concentrations. In summary, our findings could serve as a basis for the development of new natural-based drug candidates in the therapeutic field.  相似文献   
4.
5.
6.
The objective of this study was to examine the vocal symptoms and acoustic changes perceived in the short period after endotracheal intubation, and to find the association between these changes and the endotracheal tube parameters. A total of 35 subjects were included. They were examined preoperatively, and 2 and 24 hours postoperatively. The vocal symptoms of hoarseness, vocal fatigue, loss of voice, throat clearing, globus pharyngeus, throat pain, and the acoustic variables mainly average fundamental frequency, relative average perturbation, shimmer, noise to harmony ratio, voice turbulence index, habitual pitch, and maximum phonation time (MPT) were assessed as such and in relation to the following endotracheal tube parameters: duration of anesthesia, number of intubation attempts, size of the tube, cuff volume, cuff mean pressure, and the emergence. The association between anesthesia parameters with incidence of vocal complaints and changes in acoustic parameters were examined using logistic and linear regression. Vocal fatigue was associated significantly with the increase in cuff volume and the number of intubation attempts. Throat clearing was associated significantly with the increase in cuff mean pressure. Only the increase in habitual pitch was associated significantly with the increase in cuff volume. The acute short-term effect of endotracheal intubation on voice is significant. The most important endotracheal tube parameters that affect the vocal changes are the cuff mean pressure and volume. The laryngeal contribution to these vocal changes seems to be minimal. All vocal symptoms increased significantly except for globus pharyngeus at 2 hours postoperatively. The acoustic parameters did not change significantly except for a decrease in MPT. At 24 hours postoperatively, all vocal symptoms subsided with no significant difference to baseline value. The habitual pitch increased significantly, and the rest of the parameters remained comparable to baseline value.  相似文献   
7.
8.
Due to an increased awareness and significant environmental pressures from various stakeholders, companies have begun to realize the significance of incorporating green practices into their daily activities. This paper proposes a framework using Fuzzy TOPSIS to select green suppliers for a Brazilian electronics company; our framework is built on the criteria of green supply chain management (GSCM) practices. An empirical analysis is made, and the data are collected from a set of 12 available suppliers. We use a fuzzy TOPSIS approach to rank the suppliers, and the results of the proposed framework are compared with the ranks obtained by both the geometric mean and the graded mean methods of fuzzy TOPSIS methodology. Then a Spearman rank correlation coefficient is used to find the statistical difference between the ranks obtained by the three methods. Finally, a sensitivity analysis has been performed to examine the influence of the preferences given by the decision makers for the chosen GSCM practices on the selection of green suppliers. Results indicate that the four dominant criteria are Commitment of senior management to GSCM; Product designs that reduce, reuse, recycle, or reclaim materials, components, or energy; Compliance with legal environmental requirements and auditing programs; and Product designs that avoid or reduce toxic or hazardous material use.  相似文献   
9.
In this article, we study the energy decay rate for an elastic Timoshenko system. This system consists of two coupled wave equations. Only the equation about the rotation angle is damped by one locally distributed feedback at the neighbourhood of the boundary. The equation for the transverse displacement of the beam is only indirectly damped through the coupling. First, we establish an exponential energy decay rate in the case of the same speed of propagation. Next, when the wave speeds are different, a polynomial-type decay rate is obtained. These results are proved by verifying the frequency domain conditions.  相似文献   
10.
1 [2] [3] [4] [5] [6] [7] 下一页 » 末  页»
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号