首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
化学   5篇
力学   1篇
  2022年   1篇
  2019年   3篇
  2018年   1篇
  2009年   1篇
排序方式: 共有6条查询结果,搜索用时 31 毫秒
1
1.
Electroanalytical methods are highly selective for measuring electrical quantities including the charge, potential and current with their relation to chemical parameters. They are widely applied in various fields such as biochemical analysis, industrial quality control and environmental monitoring. They have many advantages over other techniques in that they are not time consuming and are specific for certain oxidation states of certain elements which give these techniques high selectivity and sensitivity features. This paper is based on two parts: the first part describes the fabrication of screen‐printed electrodes (SPEs) modified with methyl red as electroactive material, while second part describes the preparation and characterization of Fe(II)–methyl red complex using various spectroscopic tools, the complex being used for the construction of carbon paste electrodes (CPEs). The two proposed electrodes were successfully applied for the determination of Fe(II) in water and pharmaceutical (pharovit) samples. The electrodes under investigation show potentiometric response for Fe(II) in the concentration range 8.0 × 10?7–1.0 × 10?2 and 5.0 × 10?7–1.0 × 10?2 M at 25°C for SPE and CPE, respectively, and the electrode response is independent of pH in the range 1.5–7.0. These sensors show Nernstian slopes of 29.1 ± 0.2 and 29.7 ± 0.16 mV decade?1 with detection limit values of 8.0 × 10?7 and 5.0 × 10?7 M for SPE and CPE, respectively. These electrodes show fast response time of 6 and 4 s and exhibit a lifetime of 100 and 30 days for SPE and CPE, respectively. The mechanism of chemical reaction between modifier and Fe(II) on the SPE surface was studied using infrared spectra, scanning electron microscopy and energy‐dispersive X‐ray analysis. The proposed potentiometric method was validated according to the IUPAC recommendations. The results obtained using the proposed sensors were comparable with those obtained with inductively coupled plasma analysis.  相似文献   
2.
Yossri  W.  Bouma  A.  Ben Ayed  S.  Vasconcellos  R.  Abdelkefi  A. 《Nonlinear dynamics》2022,107(2):1569-1594
Nonlinear Dynamics - The effects of the aerodynamic loads on continuous wing-based systems can be represented using a quasi-steady or a fully unsteady reduced-order modeling. Frequently, the...  相似文献   
3.
A simple, sensitive and accurate spectrophotometric method for the determination of sulphonamides (sulphamethoxazole (SMZ), sulphaguanidine (SGD), sulphaquinoxaline sodium (SQX), sulphametrole (SMR), and sulphadimidine sodium (SDD)) has been developed. The charge-transfer reactions between sulphonamides as n-electron donors and 7,7,8,8-tetracyanoquinodimethane (TCNQ), 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ), and 2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone (chloranilic acid, p-CLA) as π-acceptors resulting in highly coloured complexes were studied. Experimental conditions for these CT reactions were carefully optimised. Beer’s law is valid over the concentration ranges from 4–280 μg mL−1, 4–260 μg mL−1, 4–200 μg mL−1, and 4–200 μg mL−1 of SMZ, SGD, SQX, and SDD using DDQ reagent, respectively. While the calibration curves are linear in the concentration ranges from 4–180 μg mL−1, 4–80 μg mL−1, 4–60 μg mL−1, 4–180 μg mL−1, and 4–60 μg mL−1 of SMZ, SGD, SQX, SMR, and SDD, respectively, using TCNQ reagent and from 4–380 μg mL−1 and 4–300 μg mL−1 of SQX and SDD, respectively, using p-CLA reagent, respectively. Different analytical parameters, namely molar absorptivity (ε), standard deviation, relative standard deviation, correlation coefficient, limit of detection, and limit of quantification, were calculated. The results obtained by the proposed methods are in good agreement with those obtained by the official method as indicated by the percent recovery values.  相似文献   
4.
Carbon paste electrode modified with Carboxymethyl chitosan-graft-poly(1-cyanoethanoyl-4-acryloyl-thiosemcarbazide)copolymers(CMCS-PCEATS) as ionophore was constructed for potentiometric determination of aluminum (III) and the chelation between the ionophore and the aluminum (III) ions at the electrode surface was characterized using SEM, EDX, and IR analysis. Thermal stability of the prepared electrode before and after chelation with the metal ion was investigated. The highest performance was obtained with the electrode modified with 10 mg of the prepared copolymers plasticized with TCP (electrode I). Under the optimized provision, the electrode I shows Nernstian slope of 19.9?±?0.36 mV decade??1 over the concentration range from 1.0?×?10??6 to 1.0?×?10??2 mol L??1 with a detection limit of 1.0?×?10??6 mol L??1 and pH ranges from 3 to 8. The paste is enough stable for 37 days without any detected change in the potential. The proposed method is more potent in determination of Al(III) in both real water and pharmaceutical samples potentiometrically. The results obtained agreed with those obtained with spectrophotometer and inductive coupled plasma (ICP).  相似文献   
5.
Russian Journal of Electrochemistry - Modified screen printed electrode (MSPE) with 2-[[4-(dimethyl amino) phenyl] diazenyl] benzoic acid (Methyl Red) was prepared for determination of aluminum...  相似文献   
6.
The prepared and characterized metformin ‐copper (II) complex was used as elecroactive material for modification of a new sensitive and selective modified carbon paste electrode (MCPE) for the potentiometric determination of copper (II) in water samples. The performance characteristics of MCPE were carried out. The electrode showed perfect potentiometric response for Cu (II) over concentration range of 1.0 × 10?6 – 5.0 × 10?2 mol L?1 with a detection limit of 1.0 × 10?6 mol L?1 with divalent slope value 30.8 ± 0.92 mV decade?1 over the pH range of 2–6 and exhibits fast response time of 9 s. Also, this electrode exhibited good selectivity towards Cu (II) ions with respect to other metal ions. The obtained results using the proposed electrode were in a good agreement with those obtained using the inductively coupled plasma (ICP) method.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号