首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   0篇
化学   2篇
力学   1篇
物理学   2篇
  2022年   1篇
  2011年   2篇
  2006年   1篇
  2005年   1篇
排序方式: 共有5条查询结果,搜索用时 15 毫秒
1
1.
Wang X  Chan RK  Cheng AS 《Optics letters》2005,30(10):1087-1089
We present a new type of flow cytometer that can operate underwater for a long time, as long as days, for measuring the size distribution, concentration, and biomass of marine phytoplankton. The major improvement of the instrument over existing techniques is the elimination of sample preparation, which is achieved with a laser Doppler crossed-beam arrangement for both defining a measurement volume and measuring the speed of the particle traversing it. By simultaneously sampling the laser-induced fluorescence signal and the Doppler signals, the technique can discriminate sizes of phytoplankton.  相似文献   
2.
Chan RK  Lim PK  Wang X  Chan MH 《Optics letters》2006,31(7):903-905
A beam-folding technique in optical interferometry, where the number of beam folds used can be very large, is reported. This technique can be used as a low-cost position-tracking method in a Fourier transform spectrometer (FTS) to cover the broad spectral range from UV to IR. The main advantage gained is the simple position-tracking algorithm used in sampling the interferogram. We have developed a UV-visible FTS, whose wavelength coverage is limited only by the optical elements (350 nm(-1) microm with off-the-shelf components). Preliminary results show that it can achieve a resolution of approximately 4 cm(-1) even with a ball-bearing translation stage.  相似文献   
3.
4.
Yang  Jianhua  Yang  Chen  Zhuang  Xuzhu  Liu  Houguang  Wang  Zhile 《Nonlinear dynamics》2022,107(3):2177-2193

The bearing vibration signal shows strong non-stationary property under time-varying speed conditions. In addition, the weak bearing fault characteristic is often submerged in strong background noise. How to accurately extract the unknown fault characteristic from the non-stationary vibration signal is the primary problem of bearing fault diagnosis. Stochastic resonance has been proved to be an effective weak signal enhancement method. Therefore, an unknown bearing fault detection technology of speed variation is proposed, which breaks through the periodicity limitation of the classical stochastic resonance on the input signal. It enables stochastic resonance suitable for the enhancement of non-stationary fault signal. Firstly, the non-stationary vibration signal is processed by the computed order tracking to obtain the stationary signal in angular domain. To extract the potential feature information, the bearing imaginary fault order index is constructed from the angular domain order spectrum. Then, the resonance response at the imaginary fault order is obtained. Finally, the coherence resonance theory is introduced to judge the bearing fault pattern through the resonance factor index of response order spectrum. The proposed method overcomes the fuzzy mapping relationship between the signal symptom and the bearing fault caused by speed variation. The experimental data analysis results provide effective support for the proposed method.

  相似文献   
5.
In the present study eugenol loaded solid lipid nanoparticles (SLN) was prepared and characterized for particle size, polydispersity index, zeta potential, encapsulation efficiency, in vitro release and in vivo antifungal activity. Effect of addition of liquid lipid (caprylic triglyceride) to solid lipid (stearic acid) on crystallinity of lipid matrix of SLN was determined by using Fourier transform infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC) and X-ray diffraction (XRD) techniques. Transmission electron microscopy (TEM) was carried out to determine the morphology of SLN. In vivo antifungal activity of eugenol loaded lipid nanoparticles was evaluated by using a model of oral candidiasis in immunosuppressed rats. Particle size results showed that d(90) of SLN(1) (single lipid matrix) and SLN(2) (binary lipid matrix) was 332±14.2 nm and 87.8±3.8 nm, respectively. Polydispersity index was found to be in the range of 0.27-0.4 which indicate moderate size distribution. Encapsulation efficiency of SLN(2) (98.52%) was found to be more than that of SLN(1) (91.80%) at same lipid concentration (2%, w/v). Increasing of the solid lipid concentration from 2% (w/v) to 4% (w/v) resulted in increase in encapsulation efficiency and the particle size. SLN(2) shows faster release of eugenol than that of SLN(1) due to smaller size and presence of liquid lipid which provide less barriers to the diffusion of drug from matrix. TEM study reveals the spherical shape of SLN. FT-IR, DSC and XRD results indicate less crystallinity of SLN(2) than that of SLN(1). In vivo studies show no significant difference in log cfu value of all the groups at 0 day. At 8th day, log cfu value of group treated with saline (control), standard antifungal agent, eugenol solution, SLN(1) and SLN(2) was found to be 3.89±.032, 2.69, 3.39±.088, 3.19±.028 and 3.08±0.124, respectively. The in vivo study results indicate improvement in the antifungal activity of eugenol when administrated in the form of SLN.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号