全文获取类型
收费全文 | 114篇 |
免费 | 2篇 |
专业分类
化学 | 82篇 |
晶体学 | 1篇 |
力学 | 1篇 |
数学 | 20篇 |
物理学 | 12篇 |
出版年
2023年 | 3篇 |
2021年 | 2篇 |
2020年 | 3篇 |
2018年 | 3篇 |
2016年 | 1篇 |
2014年 | 1篇 |
2013年 | 9篇 |
2012年 | 6篇 |
2011年 | 7篇 |
2010年 | 2篇 |
2009年 | 8篇 |
2008年 | 11篇 |
2007年 | 11篇 |
2006年 | 10篇 |
2005年 | 7篇 |
2004年 | 6篇 |
2003年 | 5篇 |
2002年 | 4篇 |
2001年 | 2篇 |
2000年 | 3篇 |
1995年 | 1篇 |
1994年 | 1篇 |
1993年 | 1篇 |
1992年 | 1篇 |
1989年 | 1篇 |
1987年 | 1篇 |
1985年 | 1篇 |
1983年 | 1篇 |
1978年 | 2篇 |
1971年 | 2篇 |
排序方式: 共有116条查询结果,搜索用时 15 毫秒
1.
Solveig Linko 《Accreditation and quality assurance》2002,7(2):55-59
Internal audits inherently effect quality improvement, and concrete results can be expected by careful planning. As audits
should improve the quality system in situ, the development of audits should not be neglected. ISO/IEC 17025 describes the
objectives of internal audits and management reviews in more detail compared to the former standards EN 45001 and ISO/IEC
Guide 25, although the main features are unchanged. This addresses continuous surveillance of the current practice. A brief
questionnaire on vertical audits was distributed to 74 of 120 employees at a Finnish private medical laboratory, Medix Laboratories
Ltd. A positive feed-back was received from the current management of audits. However, the study revealed that continuous
supervision of audits is needed. Many employees were not willing to perform audits if they had no previous experience. Additionally,
audits performed at the workbench were not considered as the best possible for fruitful discussions.
Received: 20 February 2001 Accepted: 30 November 2001 相似文献
2.
This paper introduces a method of combining open and closed microchannels in a single component in a novel way which couples the benefits of both open and closed microfluidic systems and introduces interesting on-chip microfluidic behaviour. Fluid behaviour in such a component, based on continuous pressure driven flow and surface tension, is discussed in terms of cross sectional flow behaviour, robustness, flow-pressure performance, and its application to microfluidic interfacing. The closed-open-closed microchannel possesses the versatility of upstream and downstream closed microfluidics along with open fluidic direct access. The device has the advantage of eliminating gas bubbles present upstream when these enter the open channel section. The unique behaviour of this device opens the door to applications including direct liquid sample interfacing without the need for additional and bulky sample tubing. 相似文献
3.
The extended Koopmans’ theorem is related to Fukui function, which measures the change in electron density that accompanies
electron attachment and removal. Two approaches are used, one based on the extended Koopmans’ theorem differential equation
and the other based directly on the expression of the ionized wave function from the extended Koopmans’ theorem. It is observed
that the Fukui function for electron removal can be modeled as the square of the first Dyson orbital, plus corrections. The
possibility of useful generalizations to the extended Koopmans’ theorem is considered; some of these extensions give approximations,
or even exact expressions, for the Fukui function for electron attachment. 相似文献
4.
Nordqvist Y Melin J Nilsson U Johansson R Colmsjo A 《Fresenius' Journal of Analytical Chemistry》2001,371(1):39-43
An air-sampling method employing denuders coated inside with a chemisorptive stationary phase has been evaluated for analysis of the hazardous gaseous 2,4 and 2,6 isomers of toluene diisocyanate (TDI). The denuder stationary phase consisted of polydimethylsiloxane (SE-30) to which dibutylamine (DBA) was added as a reagent for derivatization of TDI. The accuracy and precision of sampling by means of denuders were shown to differ only slightly from those of the established impinger method. The denuder method was, however, also shown to be suitable for long-term measurements (up to 8 h). The limit of determination (LOD) of the method, including LC-APCI-MS-MS analysis, was found to be 1.9 microg m(-3) and 1.2 microg m(-3) for 2,4- and 2,6-TDI, respectively, for short-term measurements (15 min). Significant lower LOD was obtained for long-term measurements. This is well below the Occupational Safety and Health Administration (OSHA) 8-h TWA (time-weighted average) exposure limit, which is 40 microg m(-3) for the sum of the TDI isomers. The denuder method was also found to be robust and easy to handle. The samplers can be prepared several days before sampling with no loss in performance. The contents of denuders should, on the other hand, be extracted immediately after sampling to prevent degradation of the isocyanate derivatives formed. 相似文献
5.
Thomas Garoff Solveig JohanssonKari Pesonen Päivi WaldvogelDaniel Lindgren 《European Polymer Journal》2002,38(1):121-132
In this study we prepared seven different Ziegler-Natta catalysts and polymerised them at different hydrogen concentrations in order to investigate their kinetic behaviour during polymerisation. The objective was to see whether the results corresponded to what could be expected on the basis of Kissin's β-agostic deactivation theory. According to this theory, hydrogen causes the formation of dormant sites due to the formation of β-agostic coordination from the ethyl groups formed after hydrogen termination. According to this theory, the more hydrogen that is used, the more β-agostic coupling and the smaller percentage of Ti in a polymerising state. This β-agostic coupling would thus explain the lower activity level seen in polymerisation where more hydrogen has been used.The results of this study showed that none of the catalysts showed the kind of behaviour that would correspond to what could be predicted on the basis of Kissin's theory. Deactivation could be detected only when a lower amount of hydrogen was used. When higher amounts of hydrogen were used in polymerisation there was a clear delay in activation time of the catalysts. This particularly seemed to be the case for catalysts where Ti was present as Ti(IV). This delay in the activation of the catalyst caused a decrease in activity in addition to the normal decrease in activity due to hydrogen replacing C2′′ in the polymerisation process.The only catalyst showing no delay in activation was a silica-based PE ZN catalyst where the Ti was already in trivalent form. In this case no decrease in activity was observed in addition to the normal decrease in activity caused by hydrogen replacing C2′′ in the polymerisation process. 相似文献
6.
Anders Melin 《偏微分方程通讯》2013,38(7):677-766
7.
Dr. Vibe B. Jakobsen Dr. Elzbieta Trzop Dr. Laurence C. Gavin Emiel Dobbelaar Dr. Shalinee Chikara Dr. Xiaxin Ding Dr. Kane Esien Dr. Helge Müller-Bunz Dr. Solveig Felton Dr. Vivien S. Zapf Prof. Eric Collet Prof. Michael A. Carpenter Prof. Grace G. Morgan 《Angewandte Chemie (Weinheim an der Bergstrasse, Germany)》2020,132(32):13407-13414
Domain wall motion is detected for the first time during the transition to a ferroelastic and spin state ordered phase of a spin crossover complex. Single-crystal X-ray diffraction and resonant ultrasound spectroscopy (RUS) revealed two distinct symmetry-breaking phase transitions in the mononuclear Mn3+ compound [Mn(3,5-diBr-sal2(323))]BPh4, 1. The first at 250 K, involves the space group change Cc→Pc and is thermodynamically continuous, while the second, Pc→P1 at 85 K, is discontinuous and related to spin crossover and spin state ordering. Stress-induced domain wall mobility was interpreted on the basis of a steep increase in acoustic loss immediately below the the Pc-P1 transition 相似文献
8.
9.
Recently, we proposed a novel preparative free flow zone electrophoresis cell with extremely short residence time, which does not require external cooling (Poggel, M., Melin, T., Electrophoresis 2001, 22, 1008-1015). Within the new cell the smallest chamber dimension is not orientated perpendicular but in direction of the electric field. This alteration provides straight forward scale up opportunities. In this paper, new experimental results are reported, from which the limits of stable flow can be determined. The data suggest that not density differences but electrohydrodynamic effects are responsible for the disturbance of the laminar flow pattern, which is observed above a critical field strength. To demonstrate the efficiency of the new system, a three-component mixture consisting of bovine serum albumin (BSA), myoglobin and cytochrome c is processed, resulting in relatively high recovery and purity values of the different proteins, although a complete separation is not achieved. 相似文献
10.
Anders Melin 《Journal d'Analyse Mathématique》1992,59(1):133-160
Dedicated to Professor Shmuel Agmon 相似文献