排序方式: 共有66条查询结果,搜索用时 15 毫秒
1.
Highly-charged droplets, as formed by an electrospray process, are known to undergo asymmetric fission to form smaller droplets. We have observed a chemical and physical separation phenomenon that occurs in the droplet break-up process and is related to a compound's surface activity in solution. Two experimental approaches demonstrated that the smaller satellite droplets and the progeny droplets generated by the spray formation and asymmetric fission processes to be surfactant-enriched. These smaller droplets were also effectively separated from the larger primary and residual droplets because of their smaller inertia and high surface charge density, and a region attributed to the initially formed smaller satellite droplets was found to be strikingly confined in a narrow periphery region of the electrospray. The phenomenon may have utility for chemical separations and have significant implications for the sensitivity and selectivity of electrospray ionization-mass spectrometry. 相似文献
2.
Shvartsburg AA Tang K Smith RD 《Journal of the American Society for Mass Spectrometry》2005,16(1):2-12
Field asymmetric waveform ion mobility spectrometry (FAIMS) holds significant promise for post-ionization separations in conjunction with mass-spectrometric analyses. However, a limited understanding of fundamentals of FAIMS analyzers has made their design and operation largely an empirical exercise. Recently, we developed an a priori simulation of FAIMS that accounts for both ion diffusion (including anisotropic components) and Coulomb repulsion, and validated it by extensive comparisons with FAIMS/MS data. Here it is corroborated further by FAIMS-only measurements, and applied to explore how key instrumental parameters (analytical gap width and length, waveform frequency and profile, the identity and flow speed of buffer gas) affect FAIMS response. We find that the trade-off between resolution and sensitivity can be managed by varying gap width, RF frequency, and (in certain cases) buffer gas, with equivalent outcome. In particular, the resolving power can be approximately doubled compared to "typical" conditions. Throughput may be increased by either accelerating the gas flow (preferable) or shortening the device, but below certain minimum residence times performance deteriorates. Bisinusoidal and clipped-sinusoidal waveforms have comparable merit, but switching to rectangular waveforms would improve resolution and/or sensitivity. For any waveform profile, the ratio of two between voltages in high and low portions of the cycle produces the best performance. 相似文献
3.
An adjustable low-mass filter has been developed for an electrospray ionization (ESI) source to block ions associated with unwanted background species from entering the mass spectrometer. The low-mass filter is made by using an adjustable potential energy barrier from the conductance-limiting plate of an electrodynamic ion funnel, which prohibits species with higher ion mobilities from exiting the ESI source. We show that this arrangement provides a linear voltage adjustment for low-mass filtering from m/z 0 to 500. Mass filtering above m/z 500 is also performed; however, higher-mass species are attenuated. The mass filter was tested with a liquid chromatography/mass spectrometry (LC/MS) analysis of a bovine serum albumin (BSA) tryptic digest and resulted in the ability to block low-mass, background species, which accounted for 40-70% of the total ion current immediately behind the ESI source during peak elution and detection. 相似文献
4.
Strittmatter EF Ferguson PL Tang K Smith RD 《Journal of the American Society for Mass Spectrometry》2003,14(9):980-991
We describe the application of capillary liquid chromatography (LC) time-of-flight (TOF) mass spectrometric instrumentation for the rapid characterization of microbial proteomes. Previously (Lipton et al., Proc. Natl. Acad. Sci. U.S.A. 2002, 99, 11049) the peptides from a series of growth conditions of Deinococcus radiodurans have been characterized using capillary LC MS/MS and accurate mass measurements which are captured as an accurate mass and time (AMT) tag database. Using this AMT tag database, detected peptides can be assigned using measurements obtained on a TOF due to the additional use of elution time data as a constraint. When peptide matches are obtained using AMT tags (i.e., using both constraints) unique matches of a mass spectral peak occurs 88% of the time. Not only are AMT tag matches unique in most cases, the coverage of the proteome is high; approximately 3500 unique peptide AMT tags are found on average per capillary LC run. From the results of the AMT tag database search, approximately 900 ORFs detected using LC-TOFMS, with approximately 500 ORFs covered by at least two AMT tags. These results indicate that AMT database searches with modest mass and elution time criteria can provide proteomic information for approximately one thousand proteins in a single run of <3 h. The advantage of this method over using MS/MS based techniques is the large number of identifications that occur in a single experiment as well as the basis for improved quantitation. For MS/MS experiments, the number of peptide identifications is severely restricted because of the time required to dissociate the peptides individually. These results demonstrate the utility of the AMT tag approach using capillary LC-TOF MS instruments, and also show that AMT tags developed using other instrumentation can be effectively utilized. 相似文献
5.
6.
Yiqian Gao Yucen Wang Yinghua Yan Keqi Tang Chuan‐Fan Ding 《Journal of separation science》2020,43(4):766-773
In this work, a novel, rapid, and simple analytical method was proposed for the detection of parabens in milk sample by gas chromatography coupled with mass spectrometry. At the same time, milk sample was pretreated by magnetic solid phase extraction, which detected up to five parabens. A series of important parameters of magnetic solid phase extraction were investigated and optimized, such as pH value of loading buffer, amount of material, adsorption time, ionic strength, eluting solvents, and eluting time. Under the optimized conditions, the corresponding values were more than 0.9991, limits of detection and the limit of quantification were 0.1 and 0.5 ng/mL, respectively. In addition, the recoveries were achieved in range of 95–105%, the liner range were within 0.1–600 ng/mL, and the relative standard deviations were even lower than 5%. 相似文献
7.
8.
Nonlinear Dynamics - In this paper, a novel fixed-time second-order sliding mode (SOSM) controller has been developed for a class of nonlinear systems with output constraints. Based on the output... 相似文献
9.
In the paper, a cross‐flow fan in refrigerant operating condition is systematically simulated using user‐defined functions. Three‐dimensional simulations are acquired with Navier–Stokes equations coupled with k–ε turbulence model, and internal flow characteristics of an indoor split‐type air conditioner are obtained, which is mainly composed of cross‐flow fan and heat exchanger. It has systematically been simulated in the isothermal flow condition that the performance of cross‐flow fan may be reduced easily with dry or humid air, and in the refrigerant operating condition in which user‐defined functions are applied to the humid air, considered as a mixture of dry air and vapor. A density‐modulated function is adopted to deal with the condensation of the vapor at the heat‐transfer region approximately. The results show flow mechanism of the two gas‐phase flow, including phase‐vary process. The distribution of the parameters is not uniform at the inlet of the machine, the intensity and position of pressure and velocity vary along the axial direction of the fan, the distribution of vapor volume fraction and turbulent intensity in heat‐transfer region is obtained, and the external characteristic data of the indoor machine are obtained and analyzed. Compared with the experimental data, the calculated characteristic curves and designed parameters are on target. © British Crown Copyright 2010/MOD. Reproduced with permission. Published by John Wiley & Sons, Ltd. 相似文献
10.
The transition from regular reflection (RR) to Mach reflection (MR) as a plane shock wave diffracts around a triangular mountain of 45° inclination is analysed in this paper, both by optical
measurement in a shock tube and by numerical simulation the numerical method developed by Li Yingfan[1] is of the FLIC type with triangular mesh. The dependence of the critical transition point Lk ofRR→MR on shock Mach numberM
i
is analyzed and the variations of the incidence angle ω
i
of the impinging shock and the reflection angle ω
r
with the distanceL
* are investigated. Our experimental and numerical results agree well with the theoretical results of Iton and Italya. 相似文献