首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   0篇
化学   21篇
晶体学   2篇
数学   3篇
物理学   5篇
  2022年   4篇
  2021年   4篇
  2018年   3篇
  2017年   2篇
  2014年   4篇
  2012年   1篇
  2010年   2篇
  2008年   3篇
  2007年   2篇
  2005年   2篇
  2004年   1篇
  2003年   1篇
  2002年   2篇
排序方式: 共有31条查询结果,搜索用时 15 毫秒
1.
Determination of valproic acid in the drug was carried out on the aluminum silica gel 60F254 plates and using acetone–water–chloroform–ethanol–ammonia at a volume ratio of 30:1:8:5:11 as the mobile phase, respectively. Two methods of detection of valproic acid were used. The first was a 2% aqueous CuSO4×5H2O solution, and the second was a 2′,7′-dichlorofluorescein-aluminum chloride-iron (III) chloride system. The applied TLC-densitometric method is selective, linear, accurate, precise, and robust, regardless of the visualizing reagent used for the determination of valproic acid in Convulex capsules. It has low limits of detection (LOD) and limits of quantification (LOQ), which are equal to 5.8 μg/spot and 17.4 μg/spot using a 2% aqueous CuSO4×5H2O solution as visualizing agent and also 0.32 μg/spot and 0.97 μg/spot using a 2′,7′-dichlorofluorescein-aluminum chloride-iron (III) chloride system as visualizing reagent, respectively. The described analytical method can additionally be used to study the identity of valproic acid in a pharmaceutical preparation. The linearity range was found to be 20.00–80.00 μg/spot and 1.00–2.00 μg/spot for valproic acid detected on chromatographic plates using a 2% aqueous CuSO4×5H2O solution and the 2′,7′-dichlorofluorescein-aluminum chloride-iron (III) chloride system, respectively. A coefficient of variation that was less than 3% confirms the satisfactory accuracy and precision of the proposed method. The results of the assay of valproic acid equal 96.2% and 97.0% in relation to the label claim that valproic acid fulfill pharmacopoeial requirements. The developed TLC-densitometric method can be suitable for the routine analysis of valproic acid in pharmaceutical formulations. The proposed TLC-densitometry may be an alternative method to the modern high-performance liquid chromatography and square wave voltammetry in the control of above-mentioned substances, and it can be applied when other analytical techniques is not affordable in the laboratory.  相似文献   
2.
3.
This work describes the influence of the modification of the MgCl2(THF)2 and MgCl2 magnesium supports with the AlEt2Cl, MAO, AlEt3, AlMe3, and AlEt2Cl alkylaluminium compounds on heterogenisation of the bis(cyclopentadienyl) zirconium(IV) dichloride Cp2ZrCl2 catalyst. It was found that only the MgCl2(THF)2 support modified with AlEt2Cl gave the heterogeneous catalyst. On the contrary, application of a magnesium carrier modified by AlEt3, AlMe3, and MAO compounds only results in a homogeneous zirconocene catalyst.  相似文献   
4.
JPC – Journal of Planar Chromatography – Modern TLC - Nicotinic acid (NAC) and its derivatives methyl nicotinate (MN), ethyl nicotinate (EN), isopropyl nicotinate (IPN), butyl...  相似文献   
5.
In this study, we developed a strategy to determine atto- and femtomolar amounts of metal ions in lysates and mineralizates of cells (human non-small-cell lung carcinoma (NSCLC, A549) and normal lung (MRC-5)) exposed to cytotoxic metallo-drugs: cisplatin and auranofin at concentrations close to the half-maximal inhibitory drug concentrations (IC50). The developed strategy combines data obtained using biological and chemical approaches. Cell density was determined using two independent cell staining assays using trypan blue, calcein AM/propidium iodide. Metal concentrations in lysed and mineralized cells were established employing a mass spectrometer with inductively coupled plasma (ICP-MS) and equipped with a cross-flow nebulizer working in aspiration mode. It allowed for detecting of less than 1 fg of metal per cell. To decrease the required amount of sample material (from 1.5 mL to ~100 µL) without loss of sensitivity, the sample was introduced as a narrow band into a constant stream of liquid (flow-injection analysis). It was noticed that the selectivity of cisplatin accumulation by cells depends on the incubation time. This complex is accumulated by cells at a lower efficiency than auranofin and is found primarily in the lysate representing the cytosol. In contrast, auranofin interacts with water-insoluble compounds. Despite their different mechanism of action, both metallo-drugs increased the accumulation of transition metal ions responsible for oxidative stress.  相似文献   
6.
Properties of the polyurethane-rubber composites obtained from used products were studied. The influence of the amount of polyurethane glue and amount of isocyanate diphenylmethane 4,4′-diisocyanate (MDI) on composites selected properties was observed.

The dynamic thermo-mechanical analysis allowed us to determine the glass transition temperature Tg and the course of the relaxation processes in the composites. The analysis of the changes in the storage module E′ and loss module E as a function of temperature enabled the calculation of the activation energy for relaxation processes of various polyurethane glues and polyurethane-rubber composites.  相似文献   
7.
The heterogeneous bis(cyclopentadienyl)zirconium(IV) dichloride catalyst of the composition MgCl2(THF)/(AlEt2Cl)0.34/(Cp2ZrCl2)0.01 as determined by FTIR, XRD, and AAS analyses was synthesised and, after activation by MAO, applied for ethylene polymerisation. The catalyst turned out to be stable and more active than those magnesium supported catalysts already known from the literature. The polyethylene produced has a relatively high molecular weight (Mw > 200,000 g/mol), a narrow and monomodal molecular weight distribution (MWD = 2.4), a bulk density of about 180 g/dm3, and monomodal particle size distribution. Application of a ternary Al(i-Bu)3/MAO/B(C6F5)3 activator decreased the amount of MAO needed and increased catalyst activity, but did not change the reaction mechanism.  相似文献   
8.
The diagonal linewidth in two-dimensional infrared spectra is often narrower than the distribution of transition frequencies. The width along the antidiagonal is broader than predicted by the lifetime broadening. These effects arise from time-dependent fluctuations of the transition frequencies. They can be accounted for with a semiclassical approach. For systems with many coupled vibrational modes, this approach, however, becomes computationally too demanding to be practically applicable. A time-averaging approximation was suggested for linear infrared absorption spectra. In this paper, we demonstrate that the averaging can be optimized to fit a broader scale of frequency fluctuations by using a Gaussian weight function instead of the originally proposed box function. We further generalize the time-averaging method to allow the simulation of two-dimensional infrared spectra and demonstrate the method on a simple system. The approximation delivers a large speed-up of the calculation without losing significant accuracy.  相似文献   
9.
The deterioration of food quality due to lipid oxidation is a serious problem in the food sector. Oxidation reactions adversely affect the physicochemical properties of food, worsening its quality. Lipid oxidation products are formed during the production, processing, and storage of food products. In the human diet, the sources of lipid oxidation products are all fat-containing products, including goose meat with a high content of polyunsaturated fatty acids. This study aims at comparing the fatty acid profile of goose breast muscle lipids depending on the storage conditions: type of atmosphere, temperature, and storage time. Three-way variance analysis was used to evaluate changes in the fatty acids profile occurring in goose meat. The health aspect of fatty acid oxidation of goose meat is also discussed. In general, the fatty acid composition changed significantly during storage in the meat packed in the high-oxygen modified atmosphere at different temperatures (1 °C and 4 °C). Higher temperature led to a higher degree of lipid oxidation and nutrient loss. During the storage of samples in vacuum, no changes in the fatty acid content and dietary indices were found, regardless of the storage temperature, which indicates that the anaerobic atmosphere ensured the oxidative stability of goose meat during 11 days of refrigerated storage.  相似文献   
10.
JPC – Journal of Planar Chromatography – Modern TLC - In this study, thin-layer chromatography with densitometry and gas chromatography—mass spectrometry (GC—MS) were used...  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号