全文获取类型
收费全文 | 94篇 |
免费 | 3篇 |
国内免费 | 1篇 |
专业分类
化学 | 67篇 |
晶体学 | 3篇 |
力学 | 4篇 |
物理学 | 24篇 |
出版年
2024年 | 1篇 |
2023年 | 1篇 |
2022年 | 4篇 |
2021年 | 4篇 |
2020年 | 4篇 |
2017年 | 3篇 |
2016年 | 11篇 |
2015年 | 4篇 |
2014年 | 7篇 |
2013年 | 3篇 |
2012年 | 6篇 |
2011年 | 10篇 |
2010年 | 2篇 |
2009年 | 4篇 |
2008年 | 7篇 |
2007年 | 11篇 |
2006年 | 1篇 |
2005年 | 2篇 |
2004年 | 4篇 |
2002年 | 2篇 |
2001年 | 1篇 |
2000年 | 1篇 |
1998年 | 2篇 |
1997年 | 1篇 |
1994年 | 1篇 |
1993年 | 1篇 |
排序方式: 共有98条查询结果,搜索用时 0 毫秒
1.
A. M. Yusof Z. B. Ikhsan A. K. H. Wood 《Journal of Radioanalytical and Nuclear Chemistry》1994,179(2):277-283
Dissolved inorganic arsenic species were determined in natural waters and selected marine species. Prior to irradiation by NAA samples were preconcentrated and the As(III) and As(V) species separated by APCDT-chloroform extraction. Marine samples were digested by microwave heating. Interpretation of data was achieved by comparing the ratio of As(III)/As(V) in the samples and correlating it with the prevailing environmental conditions. 相似文献
2.
Norimah Yusof A.H. Ainul Hafiza Rozaini M. Zohdi Md Zuki A. Bakar 《Radiation Physics and Chemistry》2007,76(11-12):1767-1770
Radiation at 25 and 50 kGy showed no effect on the acidic pH of the local honey, Gelam, and its antimicrobial property against Staphylococcus aureus but significantly reduced the viscosity. Honey stored up to 2 years at room temperature retained all the properties studied. Radiation sterilized Gelam honey significantly stimulated the rate of burn wound healing in Sprague-Dawley rats as demonstrated by the increased rate of wound contraction and gross appearance. Gelam honey attenuates wound inflammation; and re-epithelialization was well advanced compared to the treatment using silver sulphadiazine (SSD) cream. To enhance further the use of honey in wound treatment and for easy handling, Gelam honey was incorporated into our hydrogel dressing formulation, which was then cross-linked and sterilized using electron beam at 25 kGy. Hydrogel with 6% of honey was selected based on the physical appearance. 相似文献
3.
Norimah Yusof Asnah Hassan M.N. Firdaus Abd Rahman Suzina A. Hamid 《Radiation Physics and Chemistry》2007,76(11-12):1756-1759
Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10−1. This paper describes our experience in using the IAEA Code of Practice in conducting the validation exercise for substantiating 25 kGy as sterilisation dose for both air-dried amnion and those preserved in 99% glycerol. 相似文献
4.
Rupashree Balia Singh Subrata Mahanta Nikhil Guchhait 《Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy》2009,72(5):1103-1111
Interaction of charge transfer fluorophore N,N-dimethylaminonaphthyl-(acrylo)-nitrile (DMANAN) with globular proteins Human Serum Albumin (HSA) and Bovine Serum Albumin (BSA) brings forth a marked change in the position and intensity of band maxima both in case of absorption and fluorescence spectra. Spectroscopic approach has been elaborately implemented to explore the binding phenomena of the probe with HSA and BSA and it is found that the extent of binding of the probe to both serum albumins is similar in nature. Steady state fluorescence anisotropy values, fluorescence quenching study using acrylamide quencher and Red Edge Excitation Shift (REES) help in drawing reliable conclusions regarding the location of the probe molecule within the hydrophobic cavity of the proteins. An increase in fluorescence lifetime of the probe molecule solubilized in both the proteinous media also indicate that the probe is located at the motionally restricted environment inside the hydrophobic cavity of proteins and hence non-radiative channels are less operative than in the bulk water. Similarly, the variation of position and intensity of the emission maxima of DMANAN solubilized in micellar medium of Sodium Dodecyl Sulphate (SDS) also predicts well the critical micellar concentration (CMC) and polarity of micellar microenvironment. 相似文献
5.
The sonochemical synthesis of gold nanoparticles (GNPs) with different shapes and size distributions by using high‐intensity focused ultrasound (HIFU) operating at 463 kHz is reported. GNP formation proceeds through the reduction of Au3+ to Au0 by radicals generated by acoustic cavitation. TEM images reveal that GNPs show irregular shapes at 30 W, are primarily icosahedral at 50 W and form a significant amount of nanorods at 70 W. The size of GNPs decreases with increasing acoustic power with a narrower size distribution. Sonochemiluminescence images help in the understanding of the effect of HIFU in controlling the size and shapes of GNPs. The number of radicals that form and the mechanical forces that are generated control the shape and size of the GNPs. UV/Vis spectra and TEM images are used to propose a possible mechanism for the observed effects. The results presented demonstrate, for the first time, that the HIFU system can be used to synthesise size‐ and shape‐controlled metal nanoparticles. 相似文献
6.
Abdul Rohman Mohd AlIkhsan B. Ghazali Anjar Windarsih Irnawati Sugeng Riyanto Farahwahida Mohd Yusof Shuhaimi Mustafa 《Molecules (Basel, Switzerland)》2020,25(22)
Currently, the authentication analysis of edible fats and oils is an emerging issue not only by producers but also by food industries, regulators, and consumers. The adulteration of high quality and expensive edible fats and oils as well as food products containing fats and oils with lower ones are typically motivated by economic reasons. Some analytical methods have been used for authentication analysis of food products, but some of them are complex in sampling preparation and involving sophisticated instruments. Therefore, simple and reliable methods are proposed and developed for these authentication purposes. This review highlighted the comprehensive reports on the application of infrared spectroscopy combined with chemometrics for authentication of fats and oils. New findings of this review included (1) FTIR spectroscopy combined with chemometrics, which has been used to authenticate fats and oils; (2) due to as fingerprint analytical tools, FTIR spectra have emerged as the most reported analytical techniques applied for authentication analysis of fats and oils; (3) the use of chemometrics as analytical data treatment is a must to extract the information from FTIR spectra to be understandable data. Next, the combination of FTIR spectroscopy with chemometrics must be proposed, developed, and standardized for authentication and assuring the quality of fats and oils. 相似文献
7.
Yusof Enis Nadia Md. Ishak Nurul N. M. Latif Muhammad A. M. Tahir Mohamed I. M. Sakoff Jennette A. Page Alister J. Tiekink Edward R. T. Ravoof Thahira B. S. A. 《Research on Chemical Intermediates》2020,46(4):2351-2379
Research on Chemical Intermediates - A series of tridentate ONS Schiff bases were synthesised via condensation by reacting 2,3-dihydroxybenzaldehyde with S-2-methylbenzyldithiocarbazate (S2MBDTC)... 相似文献
8.
In this paper, we report an efficient coupling scheme with relaxed misalignment tolerances. The proposed coupling scheme consists of two ball lenses of same diameter (1 mm) and different refractive indices. The second ball lens which is facing the fiber tip has a higher refractive index (1.833), whereas the first one which faces the laser diode has a refractive index of 1.5. Employing Gaussian and ABCD ray tracing optics, the theoretically obtained coupling efficiency can reach a unity with relaxed working distance (separation of the coupling system from the fiber tip) in the range between 1 and 4 mm at some optimum positions of the coupling lenses with regard to each other and to the facet of the laser diode. It has been found that if the distance between the first ball lens and the laser diode (d1) is fixed at 1.1 mm, which is twice its focal length, the coupling efficiency and the working distance as well as the misalignment tolerances are greatly affected by variation of the separation between the two ball lenses (s), and for this proposed coupling scheme the highest coupling efficiency and largest working distance are obtained when s is in the range of 0.3-0.35 mm. Above and below this range there is a significant reduction in the values of the above-mentioned parameters. Experimentally, the Nd:YAG laser welding system has been used for the alignment and welding of the coupling components in a butterfly configuration; the experimentally obtained coupling efficiency of the proposed coupling system was around 75% with relaxed working distance. From the effect of lateral and angular offsets on coupling efficiency, it is clearly noticed that the mode field of laser diode is transformed from elliptical into circular and hence effectively matched with that of the single-mode fiber. 相似文献
9.
A polymer electrolyte system comprising methylcellulose (MC) as the host polymer and lithium bis(oxalato) borate (LiBOB) as the lithium ion source has been prepared via the solution cast technique. The electrolyte with the highest conductivity of 2.79 μS cm?1 has a composition of 75 wt% MC–25 wt% LiBOB. The mobile ion concentration (n) in this sample was estimated to be 5.70?×?1020 cm?3. A good correlation between ionic conductivity, dielectric constant, and free ion concentration has been observed. The ratio of mobile ion number density (n) at a particular temperature to the concentration n 0 of free ions at T?=?∞ (n/n 0) and the power law exponents (s) exhibit opposite trends when varied with salt concentration. 相似文献
10.
Norimah Yusof Ros Anita Ahmad Ramli Foziah Ali 《Radiation Physics and Chemistry》2007,76(11-12):1882-1884
A study was carried out to determine optimum decontamination dose for a locally manufactured coconut cream powder. Samples were gamma irradiated (0–15 kGy) and ageing process was achieved using GEER oven at 60 °C for 7 days, which is equivalent to one-year storage at room temperature. Iodine value (IV), ranging from 4.8 to 6.4, was not affected by radiation doses and storage, however peroxide value and thiobarbituric acid (TBA) generally increased with radiation doses. In most samples, peroxide value (meq/kg) reduced after storage, whilst the TBA (mg malonaldehyde/kg), indicator for product quality, slightly increased. The sensory evaluation conducted using 25 taste panellists indicated that scores on odour, creamy taste and overall acceptance for all irradiated samples at more than 5 kGy were significantly lower (P<0.05) than the control. However, the panellists could not detect any significant differences among the irradiation doses (P>0.05). All stored products were significantly different in colour, creamy taste, odour and overall acceptance (P<0.05) when compared to the non-stored non-irradiated control. Microbiological count of the samples prior to irradiation was in the range of 1×102–1.7×103 cfu/g with no detection of Salmonella sp. and Escherichia coli. No microbial colonies were detected after irradiation. Based on the TBA and overall sensory acceptance, gamma irradiation of 5 kGy was found to be the optimum dose and lower doses can be considered to decontaminate coconut cream powder. 相似文献