首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   0篇
化学   5篇
  2010年   1篇
  2005年   1篇
  1998年   2篇
  1995年   1篇
排序方式: 共有5条查询结果,搜索用时 15 毫秒
1
1.
The suitability of a new technology single-monochromator diode array spectroradiometer for UV-radiation safety measurements, in particular for sunbed measurements, was evaluated. The linearity, cosine response, temperature response, wavelength scale, stray-light and slit function of the spectroradiometer were determined and their effects on the measurement accuracy evaluated. The main error sources were stray-light and nonideal cosine response, for which correction methods are presented. Without correction, the stray-light may reduce the accuracy of the measurement excessively, particularly in the UV-B range. The expanded uncertainty of the corrected UV measurements is estimated to be 14%, which is confirmed with the comparative measurements carried out with a well-characterized double-monochromator spectroradiometer. The measurement accuracy is sufficient for sunbed measurements, provided that all corrections described above have been done and the user of the instrument has a good understanding of the instrument's operating principles and potential error sources. If these requirements are met, the tested spectroradiometer improves and facilitates market surveillance field measurements of sunbeds.  相似文献   
2.
The specific heat capacities (cp) for the brain and muscle equivalent liquids were determined with isothermal heat conduction microcalorimetry (IMC) and differential scanning calorimetry (DSC). IMC was found to afford an accurate technique to measure cp for solid and liquid samples, when an appropriate reference is employed. The accuracy of obtained cp values was estimated to be better than 0.7% with the equivalent liquids. Intercomparison with a conventional isoperibolic calorimeter showed an excellent agreement within the estimated uncertainty of the isoperibolic calorimeter (±3%). Additionally, suitability of different kinds of IMC sample vessels was tested, and the standard electrical calibration procedure of IMC was evaluated through the determination of cp with and without a reference material. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   
3.
INCREASED UV EXPOSURE IN FINLAND IN 1993   总被引:1,自引:0,他引:1  
Abstract—
Exceptionally low total ozone, up to 40% below the normal level, was measured over Northern Europe during winter and spring in 1992 and 1993. In 1993 the depletion persisted up to the end of May, resulting in a significant increase of biologically effective UV radiation. The increases were significantly smaller in 1992 and 1994 than in 1993. The UV exposure of the Finnish population was evaluated through measurements and theoretical calculations. The increase in measured erythemal (International Lighting Commission) UV falling onto horizontal surfaces on clear days was determined relative to model calculations for an average ozone amount. The increase was on average 10% from April to May 1993, and the maximal measured increase was 34%. Theoretical calculations for both erythemal and carcinogenic (Skin Cancer Utrecht-Philadelphia) UV indicated that in 1993 the theoretical annual increase to a vertical (cylinder) surface ranged from 8 to 13% in Finland. The reflection of UV from snow considerably increases facial UV doses in Northern Finland.  相似文献   
4.
The objective of the study was to compare Bacillus subtilis spore film dosimeters with a Robertson Berger UV meter (RB meter) and diary records for assessing personal UV-B doses during a 13-day heliotherapy (HT) for atopic dermatitis (AD). In addition, the relationship between the personal UV-B dose and change in serum 25-hydroxyvitamin D (25(OH)D) was studied. Altogether 21 adult patients with AD completed the study arranged in the Canary Islands, either in January or March 2005. The spore film dosimeters were used throughout the day during the HT. Serum 25(OH)D was analyzed using radioimmunoassay. The mean personal UV-B dose measured with the dosimeters was 75 SED in January and 131 SED in March. The respective results gained from the RB meter combined with diary records were 63 SED and 119 SED showing a close correlation with the dosimeter results. Serum 25(OH)D concentration increased by 9.7 nmol L−1 in January and by 26.0 7 nmol L−1 in March. The increase in serum 25(OH)D correlated with the UV-B dose received. The patients complied well to use the dosimeters. We conclude spore films to be a feasible and reliable personal UV dosimeter in vivo in field conditions.  相似文献   
5.
The first international intercomparison of erythemally weighted (EW) broadband radiometers was arranged in 1995 to improve the accuracy and comparability of the measurements carried out by solar UV monitoring networks. The intercomparison was arranged at the Radiation and Nuclear Safety Authority in Helsinki, Finland, in cooperation with the University of Innsbruck and with support from the World Meteorological Organization. Altogether 20 EW meters of six different types from 16 countries were (1) tested in the laboratory by measuring the spectral and angular responsivities and (2) calibrated in solar radiation against two reference spectroradiometers. Calibration factors (CFs) for the EW meters were determined by using simultaneously measured EW solar UV spectra as a calibration reference. The CFs averaged over solar elevations higher than 35° varied from 0.87 to 1.75, with the estimated uncertainty being ±10%. As a result of this intercomparison, for the first time the calibrations of more than 100 EW radiometers around the world are possible to trace to the same origin. The present experience indicates that the accuracy of temperature-controlled EW radiometers is not significantly lower than the accuracy of spectroradiometers provided that strict quality assurance/quality control procedures are followed.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号