Research on Chemical Intermediates - MCM-41-SO3H, ordered mesoporous silica material MCM-41 with covalently anchored sulfonic acid groups, was used as a solid acid catalyst for the convenient,... 相似文献
A nanofiber polypyrrole (PPy) film was electrochemically deposited on a Pt electrode and used for immobilization of single‐stranded DNA (ssDNA) and investigation of hybridization events. Then, the interaction of DNA with four salicylic acid (SA) derivatives was studied with electrochemical methods. The oxidation peak of guanine was decreased by increasing the concentrations of salicylic acid derivatives. The binding constants of these compounds with four different sequences of DNA including different percentages of guanine‐cytosine and adenine‐thymine bases were calculated and it was clarified that sequences with higher percentage of adenine‐thymine bases have a higher binding constant in their interaction with SA derivatives. 相似文献
Mercury exists in two forms in environment, inorganic salts and organic compounds. Determination of mercury is very important, due to its health effects. In the present research, diphenylation of mercury using phenylboronic acid as a derivatization reagent was used for the determination of Hg(II) in real water samples. A simple, rapid and cheap method named dispersive liquid–liquid microextraction was used for the extraction of analyte under the following conditions: extraction solvent 16 μL of carbon tetrachloride, disperser solvent 1 mL of ethanol and sample volume 5 mL. Under the optimal conditions, the enrichment factor for diphenylmercury was 931 and the limit of detection calculated on the basis of five replicates was 0.004 μg mL?1. The repeatability of the method expresses as relative standard deviation was 5.1 (n = 6). The linear range was between 0.01 and 10 μg mL?1. The performance of the proposed technique was evaluated for the determination of mercury in different environmental water samples. 相似文献
This study presents [99mTc]BPTG-1 and [99mTc]BPTG-2 for glioblastoma imaging. In vitro cellular uptakes of these radiotracers were examined in SKOV-3, MCF-7, U87-MG, HT-29, and A549 cell lines. U87-MG cell line displayed the highest radiotracers uptakes. Biodistribution study in U87-MG tumor bearing mice revealed higher uptake of radiotracers in tumor than muscle and brain. Liver, intestine, and kidneys displayed the highest radioactivity uptakes. The main route of radiotracers elimination was hepatobiliary. Due to the brain uptake of these radiotracers, they are promising radiotracers for future studies in the diagnosis of glioblastoma.
<正>A new practical method for the synthesis of unsymmetrical ureas was achieved by reaction of phenylurea with primary and secondary amines under neutral and mild condition in very good yields.The reaction took place in refluxing dioxane and does not require any catalyst or additives. 相似文献
A facile synthesis of novel spiroindane-1,3-diones has been achieved via 1,3-dipolar cycloaddition of an azomethine ylide, generated in situ from ninhydrin and 1,2,3,4-tetrahydroisoquinoline, with the conjugated double bond of chalcone derivatives. The regiochemistry and structures of the cycloadducts were determined with spectroscopic data and by X-ray crystal structure analysis. 相似文献
Rapid, inexpensive, and efficient sample-preparation by dispersive liquid–liquid microextraction (DLLME) then gas chromatography with flame ionization detection (GC–FID) have been used for extraction and analysis of BTEX compounds (benzene, toluene, ethylbenzene, and xylenes) in water samples. In this extraction method, a mixture of 25.0 μL carbon disulfide (extraction solvent) and 1.00 mL acetonitrile (disperser solvent) is rapidly injected, by means of a syringe, into a 5.00-mL water sample in a conical test tube. A cloudy solution is formed by dispersion of fine droplets of carbon disulfide in the sample solution. During subsequent centrifugation (5,000 rpm for 2.0 min) the fine droplets of carbon disulfide settle at the bottom of the tube. The effect of several conditions (type and volume of disperser solvent, type of extraction solvent, extraction time, etc.) on the performance of the sample-preparation step was carefully evaluated. Under the optimum conditions the enrichment factors and extraction recoveries were high, and ranged from 122–311 to 24.5–66.7%, respectively. A good linear range (0.2–100 μg L−1, i.e., three orders of magnitude; r2 = 0.9991–0.9999) and good limits of detection (0.1–0.2 μg L−1) were obtained for most of the analytes. Relative standard deviations (RSD, %) for analysis of 5.0 μg L−1 BTEX compounds in water were in the range 0.9–6.4% (n = 5). Relative recovery from well and wastewater at spiked levels of 5.0 μg L−1 was 89–101% and 76–98%, respectively. Finally, the method was successfully used for preconcentration and analysis of BTEX compounds in different real water samples.
Some new amidated fentanyl (=N‐[1‐(2‐phenylethyl)piperidin‐4‐yl]‐N‐phenylpropanamide) analogs with a 4‐(N‐phenylamido)piperidine scaffold and additional amide bonds have been designed and synthesized through Ugi four‐component reaction (Ugi‐4CR). Good‐to‐high yields, diversity‐oriented synthesis, and possible applications in drug discovery are advantages of this approach. 相似文献
The sufficient amounts of bis(salicylaldehyde) thiocarbohydrazone (STCH) as a lipophilic selective element (3%, w/w), sodium nitrobenzene (NB) as a plasticizer (64%, w/w), tetraphenyl borate (NaTPB) as an anionic additive (3%, w/w), and poly vinyl chloride (PVC) as a polymeric matrix (30%, w/w) was employed to form a PVC membrane of a new Pr3+ ions selective sensor to apply as an indicator electrode in analytical applications. The best electrode response was observed in the slope (19.5 ± 0.7 mV per decade) over a wide concentrations from lower (1.0 × 10?6 mol L–1) to higher (1.0 × 10?2 mol L–1) of Pr3+ ion solution with a detection limit of 8.5 × 10–7 mol L–1. This electrode showed the fast response time about 10 second for praseodymium ion concentration range of 1.0 × 10–6 to 1.0 × 10–2 mol L–1, in the pH range of 2.3–7.9. The matched potential method was applied to study the selectivity of electrode toward Pr3+ ions in comparison with many common cations. The results showed the negligible disturbance of all other cations on the proposed praseodymium(III) electrode. The making sensor has been employed successfully as an indicator electrode in the potentiometric titration of praseodymium(III) solution with EDTA at pH 6.0. Moreover the applicability of the sensor was studied in determination of Pr3+ ion in mixtures of different ions. 相似文献