排序方式: 共有10条查询结果,搜索用时 0 毫秒
1
1.
2.
Overtone spectrum of o, m and p-nitrobenzaldehydes and p-chlorobenzaldehyde has been studied in 2000–12000 cm−1 region. Vibrational frequencies and anharmonicity constants for aryl as well as alkyl CH stretch vibrations have been determined.
We have also determined the internuclear distances for the aryl CH bond in the different molecules. The small variation observed
in these distances is an indication of the substitution effect.
It is observed that in the case of p-disubstituted benzens, the shift in aryl CH bond is proportional to sum of the Hammet σ of the substituents. However in the
case of o-disubstituted benzenes it is only 80% of the para-substituted shift. 相似文献
3.
With the advent of medium and large gamma detector arrays, it is now possible to look at nuclear structure at high rotational
forces. The role of pairing correlations and their eventual breakdown, along with the shell effects have showed us the interesting
physics for nuclei at high spins — superdeformation, shape co-existence, yrast traps, alignments and their dramatic effects
on nuclear structure and so on. Nuclear structure studies have recently become even more exciting, due to efforts and possibilities
to reach nuclei far off from the stability valley. Coupling of gamma ray arrays with ‘filters’, like neutron wall, charged
particle detector array, gamma ray total energy and multiplicity castles, conversion electron spectrometers etc gives a great
handle to study nuclei produced online with ‘low’ cross-sections. Recently we studied, nuclei in mass region 80 using an array
of 8 germanium detectors in conjunction with the recoil mass analyser, HIRA at the Nuclear Science Centre and, most unexpectedly
came across the phenomenon of identical bands, with two quasi-particle difference. The discovery of magnetic rotation is another
highlight. Our study of light In nucleus, 107In brought us face to face with the ‘dipole’ bands. I plan to discuss some of
these aspects. There is also an immensely important development — that of the ‘radioactive ion beams’. The availability of
RIB, will probably very dramatically influence our ‘conventional’ concept of nuclear structure. The exotic shapes of these
exotic nuclei and some of their expected properties will also be touched upon. 相似文献
4.
Rare earth element substituted bismuth ferrites (BiFeO3) are of enormous importance as magnetoelectric materials. The polycrystalline samples of Bi
x
La1−x
FeO3 (x=0, 0.2, 0.4, 0.6, 0.8) were prepared by solid-state reaction using standard ceramic method. The single-phase formation of
these compounds was confirmed by X-ray diffraction (XRD) studies. The samples with x=0, 0.2, 0.4, 0.6 are found to be orthorhombic while the sample with x=0.8 is triclinic. The dielectric constant (ε′) and dissipation factor (tan δ) were measured in the frequency range 100 Hz
to 1 MHz at room temperature and as a function of temperature at certain fixed frequencies (1 kHz, 10 kHz, 100 kHz, 1 MHz).
All the samples showed dielectric dispersion. The dielectric constant with temperature shows a broad peak; the peak temperature
shifts with frequency which reflects the relaxor-type behavior. The peak above 600 K in the measured temperature range corresponds
to antiferromagnetic ordering temperature (Néel temperature). The broadness of the peak changes with composition. The ac conductivity
as well as ε′ are found to be maximum for the sample x=0.2 at room temperature. 相似文献
5.
Dunn-Meynell KW Wainhaus S Korfmacher WA 《Rapid communications in mass spectrometry : RCM》2005,19(20):2905-2910
For higher throughput screening, where the number of new chemical entities (NCEs) to test is rapidly increasing, fast sample turnaround time is essential. In order to increase efficiency a generic high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method, with a cycle time of 85 s (42 injections/h), was created. This was accomplished through the use of a 1-min ballistic gradient and the optimization of the autosampler. The gradient was optimized by varying the organic mobile phase concentration and examining its ballistic characteristics with respect to matrix ion suppression and compound retention time. The autosampler time could be reduced by optimizing several parameters and by determining the source of most of the carryover in order to reduce the number of syringe and injector washes. Finally, the reliability of the new generic method is demonstrated by comparison of sample data with a standard 2-min linear gradient method that showed that the data sets were well correlated. For plasma AUC (ng.h/mL) of 28 NCEs, the regression line had a slope of 0.92 and the R2 was 0.929. The described method was found to be useful for both rat plasma and tissue samples. 相似文献
6.
Huawei Li Hong Liu C Eduardo Corrales Jessica R Risner Jeff Forrester Jeffrey R Holt Stefan Heller Albert SB Edge 《BMC neuroscience》2009,10(1):122
Background
Neural differentiation of embryonic stem (ES) cells is usually achieved by induction of ectoderm in embryoid bodies followed by the enrichment of neuronal progenitors using a variety of factors. Obtaining reproducible percentages of neural cells is difficult and the methods are time consuming. 相似文献7.
8.
Samuel B. Wainhaus Nitzan Tzanani Shai Dagan Mark L. Miller Aviv Amirav 《Journal of the American Society for Mass Spectrometry》1998,9(12):1311-1320
A new method for the fast screening of cocaine and 6-monoacetylmorphine (6-MAM) in a single hair, using gas chromatography/mass spectrometry (GC/MS), is described. The analyses are conducted in less than 10 min with minimal sample preparation. The novel method combines the ChromatoProbe direct sample introduction device for intrainjector thermal extraction, fast GC separation, a supersonic molecular beam GC/MS interface and hyperthermal surface ionization (HSI). The technique has been successfully employed for the detection of cocaine in as little as a 1-mm section of hair using selected ion monitoring (SIM). Unambiguous full scan mass spectra of cocaine and 6-MAM were obtained on a single hair for cocaine and heroin users, respectively. HSI was found to be almost 3 orders of magnitude more selective than electron impact ionization for cocaine compared with the major hair constituents, with a minimum detected concentration of approximately 10 ppb in the SIM mode. Results obtained for 12 drug users showed full qualitative agreement with similar results using rigorous solvent extraction followed by electrospray-liquid chromatography/mass spectrometry analysis. However, quantitative studies showed only partial agreement. No false positives were observed for 10 drug free subjects. This method enables fast drug monitoring along the hair length which permits time correlation studies. 相似文献
9.
Korfmacher WA Cox KA Ng KJ Veals J Hsieh Y Wainhaus S Broske L Prelusky D Nomeir A White RE 《Rapid communications in mass spectrometry : RCM》2001,15(5):335-340
This report addresses the continuing need for increased throughput in the evaluation of new chemical entities (NCEs) in terms of their pharmacokinetic (PK) parameters by describing an alternative procedure for increasing the throughput of the in vivo screening of NCEs in the oral rat PK model. The new approach is called "cassette-accelerated rapid rat screen" (CARRS). In this assay, NCEs are dosed individually (n = 2 rats/compound) in batches of six compounds per set. The assay makes use of a semi-automated protein precipitation procedure for sample preparation in a 96-well plate format. The liquid chromatography/atmospheric pressure ionization tandem mass spectrometry (LC/API-MS/MS) assay is also streamlined by analyzing the samples as "cassettes of six". Using this new approach, a threefold increase in throughput was achieved over the previously reported "rapid rat screen". 相似文献
10.
Hua Y Wainhaus SB Yang Y Shen L Xiong Y Xu X Zhang F Bolton JL van Breemen RB 《Journal of the American Society for Mass Spectrometry》2001,12(1):80-87
Oxidized deoxynucleosides are widely used as biomarkers for DNA oxidation and oxidative stress assessment. Although gas chromatography mass spectrometry is widely used for the measurement of multiple DNA lesions, this approach requires complex sample preparation contributing to possible artifactual oxidation. To address these issues, a high performance liquid chromatography (HPLC)-tandem mass spectrometric (LC-MS/MS) method was developed to measure 8-hydroxy-2'-deoxyguanosine (8-OH-dG), 8-hydroxy-2'-deoxyadenosine (8-OH-dA), 2-hydroxy-2'-deoxyadenosine (2-OH-dA), thymidine glycol (TG), and 5-hydroxy-methyl-2'-deoxyuridine (HMDU) in DNA samples with fast sample preparation. In order to selectively monitor the product ions of these precursors with optimum sensitivity for use during quantitative LC-MS/MS analysis, unique and abundant fragment ions had to be identified during MS/MS with collision-induced dissociation (CID). Positive and negative ion electrospray tandem mass spectra with CID were compared for the analysis of these five oxidized deoxynucleosides. The most abundant fragment ions were usually formed by cleavage of the glycosidic bond in both positive and negative ion modes. However, in the negative ion electrospray tandem mass spectra of 8-OH-dG, 2-OH-dA, and 8-OH-dA, cleavage of two bonds within the sugar ring produced abundant S1 type ions with loss of a neutral molecule weighing 90 u, [M - H - 90]-. The signal-to-noise ratio was similar for negative and positive ion electrospray MS/MS except in the case of thymidine glycol where the signal-to-noise was 100 times greater in negative ionization mode. Therefore, negative ion electrospray tandem mass spectrometry with CID would be preferred to positive ion mode for the analysis of sets of oxidized deoxynucleosides that include thymidine glycol. Investigation of the fragmentation pathways indicated some new general rules for the fragmentation of negatively charged oxidized nucleosides. When purine nucleosides contain a hydroxyl group in the C8 position, an S1 type product ion will dominate the product ions due to a six-membered ring hydrogen transfer process. Finally, a new type of fragment ion formed by elimination of a neutral molecule weighing 48 (CO2H4) from the sugar moiety was observed for all three oxidized purine nucleosides. 相似文献
1