首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   1篇
化学   20篇
数学   1篇
  2023年   1篇
  2022年   2篇
  2020年   2篇
  2019年   2篇
  2014年   1篇
  2013年   2篇
  2012年   5篇
  2011年   1篇
  2008年   1篇
  2007年   2篇
  2005年   1篇
  2004年   1篇
排序方式: 共有21条查询结果,搜索用时 15 毫秒
1.
This report describes the use of PDMS ME coupled with amperometric detection for rapid separation of ascorbic, gallic , ferulic, p‐coumaric acids using reverse polarity. ME devices were fabricated in PDMS by soft lithography and detection was accomplished using an integrated carbon fiber working electrode aligned in the end‐channel configuration. Separation and detection parameters were investigated and the best conditions were obtained using a run buffer consisting of 5 mM phosphate buffer (pH 6.9) and a detection voltage of 1.0 V versus Ag/AgCl reference electrode. All compounds were separated within 70 s using gated injection mode with baseline resolution and separation efficiencies between 1200 and 9000 plates. Calibration curves exhibited good linearity and the LODs achieved ranged from 1.7 to 9.7 μM. The precision for migration time and peak height provided maximum values of 4% for the intrachip studies. Lastly, the analytical method was successfully applied for the analysis of ascorbic and gallic acids in commercial beverage samples. The results achieved using ME coupled with amperometric detection were in good agreement with the values provided by the supplier. Based on the data reported here, the proposed method shows suitability to be applied for the routine analysis of beverage samples.  相似文献   
2.
A low-cost and straightforward hybrid NOA (Norland optical adhesive) 81-glass microchip electrophoresis device was designed and developed for protein separation using indirect fluorescence detection. This new microchip was first characterized in terms of surface charge density via electroosmotic mobility measurement and stability over time. A systematic determination of the electroosmotic mobility (μeo) over a wide pH range (2–10) and at various ionic strengths (20–50 mM) was developed for the first time via the neutral marker approach in an original simple frontal methodology. The evolution of μeo was proved consistent with the silanol and thiol functions arising from the glass and the NOA materials, respectively. The repeatability and reproducibility of the measurements on different microchips (RSD < 14%) and within 15 days (less than 5% decrease) were successfully demonstrated. The microchip was then applied for the efficient electrophoretic separation of proteins in a zonal mode coupled with indirect fluorescence detection, which is, to our knowledge, the first proof of concept of capillary zone electrophoresis in this hybrid microsystem.  相似文献   
3.
The application of plastified laser-printed poly(ethylene terephthalate)(PET)-toner microchips to capillary electrophoresis was investigated. Electroosmotic flow was observed in the direction of the cathode for the buffer system studied (phosphate, pH 3–10). Average electroosmotic mobilities of 1.71×10–4 to 4.35×10–4 cm2 V–1 s–1 were observed from pH 3 to 10. This variation suggests that silica fillers in the toner and on the surface of the polymer dominate the zeta potential of the material, which is also confirmed by XPS measurements. Dopamine and catechol were used as model analytes for microchip electrophoresis in combination with electrochemical detection. Results show that these two analytes can be efficiently separated and detected electrochemically with the plastified laser-printed PET-toner microchips.  相似文献   
4.
This study describes the development of an analytical methodology based on the use of microchip electrophoresis (ME) devices integrated with capacitively coupled contactless conductivity detection (C4D) for the separation and detection of inorganic anions in post‐blast explosive residues. The best separation condition was achieved using a running buffer composed of 35 mmol/L lactic acid, 10 mmol/L histidine and 0.070 mmol/L cetyl(trimethyl ammonium) bromide. For C4D measurements, the highest sensitivity was obtained applying a 700 kHz sinusoidal wave with excitation voltage of 20 Vpp. The separation of Cl?, NO3?, NO2?, SO42?, ClO4? and ClO3? was performed within ca. 150 s with baseline resolution and efficiencies between 4.4 × 104 and 1.7 × 105 plates/m. The found limits of detection ranged between 2.5 and 9.5 μmol/L. Last, real samples of post‐blast explosive residues were analyzed on the ME‐C4D devices obtaining successfully the determination of Cl?, NO3? and SO42?. The achieved concentration values varied between 12.8–72.5 mg/L for Cl?, 1.7–293.1 mg/L for NO3? and 1.3–201.3 mg/L for SO42?. The data obtained using ME‐C4D devices were in good agreement with the concentrations found by ion chromatography. The approach reported herein has provided short analysis time, instrumental simplicity, good analytical performance and low cost. Furthermore, the ME‐C4D devices emerge as a powerful and portable analytical platform for on‐site analysis demonstrating to be a promising tool for the crime scene investigation.  相似文献   
5.
In this report, we describe the microfabrication and integration of planar electrodes for contactless conductivity detection on polyester-toner (PT) electrophoresis microchips using toner masks. Planar electrodes were fabricated by three simple steps: (i) drawing and laser-printing the electrode geometry on polyester films, (ii) sputtering deposition onto substrates, and (iii) removal of toner layer by a lift-off process. The polyester film with anchored electrodes was integrated to PT electrophoresis microchannels by lamination at 120 degrees C in less than 1 min. The electrodes were designed in an antiparallel configuration with 750 microm width and 750 microm gap between them. The best results were recorded with a frequency of 400 kHz and 10 Vpp using a sinusoidal wave. The analytical performance of the proposed microchip was evaluated by electrophoretic separation of potassium, sodium and lithium in 150 microm wide x 6 microm deep microchannels. Under an electric field of 250 V/cm the analytes were successfully separated in less than 90 s with efficiencies ranging from 7000 to 13,000 plates. The detection limits (S/N = 3) found for K+, Na+, and Li+ were 3.1, 4.3, and 7.2 micromol/L, respectively. Besides the low-cost and instrumental simplicity, the integrated PT chip eliminates the problem of manual alignment and gluing of the electrodes, permitting more robustness and better reproducibility, therefore, more suitable for mass production of electrophoresis microchips.  相似文献   
6.
Over the past years, the development of capillary electrophoresis (CE) and microchip electrophoresis (ME) systems has grown due to instrumental simplicity and wide application. In both CE and ME, the application of a high voltage (HV) is a crucial step in the electrokinetic (EK) injection and separation processes. Particularly on ME devices, EK injection is often performed with three different modes: gated, pinched, and unpinched. In all these cases, different potential values may be applied to one or multiple channels to control the injection of small sample volumes as well as the separation process. For this reason, the construction of reliable HV power supplies (HVPS) is required. This review covers the advances of the development of commercial and laboratory-built HVPS for CE and ME. Moreover, it intends to be a guide for new developers of electrophoresis instrumentation.  相似文献   
7.
This study reports the separation of fructose, galactose, glucose, lactose and sucrose on glass microchip electrophoresis (ME) devices using a microfluidic platform adapted with external reservoirs for controlling the electrolysis phenomenon. The connections between external reservoirs and microfluidic platform were performed by saline bridges created using silicone tubing filled with BGE. The separation conditions were optimized and the best results were achieved using a BGE containing 75 mmol/L NaOH and 15 mmol/L trisodium phosphate. Electrophoretic separations were monitored using a capacitively coupled contactless conductivity detection system. The controlled electrolysis has successfully allowed the application of a higher voltage on the separation channel promoting the baseline separation of five carbohydrates within 180 s with great run‐to‐run repeatability (RSD < 1%). The achieved efficiencies ranged from 45 000 ± 6000 to 70 000 ± 3000 plates/m demonstrating a performance better than ME devices without controlled electrolysis. The proposed system offered good linearity from 1 to 10 mmol/L and LODs between 150 and 740 μmol/L. The use of external tubes for controlling the electrolysis phenomenon on ME devices has solved common problems associated to run‐to‐run repeatability and analytical reliability required for routine and quantitative analysis.  相似文献   
8.
Reproducible and representative sample injection in microchip electrophoresis has been a bottleneck for quantitative analytical applications. Electrokinetic sample injection is the most used because it is easy to perform. However, this injection method is usually affected by sample composition and the bias effect. On the other hand, these drawbacks are overcome by the hydrodynamic (HD) sample injection, although this injection mode requires HD flow control. This review gives an overview of the basic principles, the instrumentation designs, and the performance of HD sample injection systems for microchip electrophoresis.  相似文献   
9.
We report a glass/PDMS-based microfluidic biosensor that integrates contactless conductivity transduction and folic acid, a target for tumor biomarker, as a bioreceptor. The device presents relevant advantages such as direct determination--dismiss the use of redox mediators as in faradaic electrochemical techniques--and the absence of the known drawbacks related to the electrode-solution interface. Characterizations of the functionalization processes and chemical sensor are described in this communication.  相似文献   
10.
Six stretch PVC films have been formulated to have Shore A hardness of approx. 80 and nominal thickness of 15 μm with the aim of evaluating the performance of plasticizers from renewable and non-renewable sources for stretch PVC films intended to be employed as packaging. The reference film was produced with DEHA and ESBO, while the other films were produced with conventional plasticizers (ATBC and Polyadipate), new plasticizers from renewable sources (Mixture of glycerin acetates and Acetic acid esters of mono- and diglycerides of fatty acids) or a plasticizer employed in toy and childcare applications (DEHT) as a third plasticizer. The films were evaluated as to their physical and mechanical properties (durometer hardness, tensile strength and elongation), IR spectroscopy and light transmission. The several plasticizers influenced the mechanical properties of the PVC films to different degrees. All films will probably show adequate performance when used in packaging applications. Nevertheless, the vegetable oil-based plasticizers showed better mechanical performance than the other plasticizers when compared to DEHA.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号