首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   15篇
  免费   0篇
化学   7篇
数学   1篇
物理学   7篇
  2019年   1篇
  2013年   3篇
  2012年   4篇
  2008年   1篇
  2002年   1篇
  1999年   3篇
  1994年   1篇
  1978年   1篇
排序方式: 共有15条查询结果,搜索用时 62 毫秒
1.
In this article we compare the classical monopole mass filter of von Zahn and the monopole mass filter with a hyperbolic V-shaped electrode. The experimental results and those of computer simulation for both mass spectrometers are presented. We show that the replacement of a conventional 90 degrees V-shaped electrode by an electrode with a hyperbolic profile substantially improves the peak shape of any given mass, and increases the mass resolution by a factor of 3-4 and the abundance sensitivity by a factor of 100. The potential of high analytical performance combined with electroforming techniques for electrode manufacture indicate future practical uses of such instruments. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
2.
VS Bhasin 《Pramana》1999,53(3):567-575
The discovery of neutron rich isotopes of the lightest elements on the neutron drip line exhibiting a halo structure has opened up new vistas in research activities. The novel structural features associated with the halo phenomena have been the subject for extensive theoretical and experimental investigations in recent times. In this talk, I propose to present a broad overview of the recent developments in this field, bringing out the striking features which show that a large number oflight nuclei near the neutron drip line are characterized by a clear separation between a ‘normal’ core nucleus and a loosely bound low density veil of neutrons. Specifically, the two neutron halos offer a natural premises, from a theoretical standpoint, to employ three body techniques for studying their detailed structural properties. A considerable part of the talk will be devoted to report and highlight the results on a number of light halo nuclei such as 11Li, 11Be, 19B and 22C on which we have been carrying out investigations employing a simple but realistic three body model. These three body systems which have been termed as ‘Borromean’ (i.e while three body systems are bound, the corresponding binary subsystems on the other hand are unbound) are characterized by large spacial extension and very low separation energy of the neutron. They are, therefore, ideally suited for exploring the possibility of the existence of Efimov states in two neutron halo nuclei. We have recently carried out the three body analyses to predict the possibility of the occurrence of such states on which experimental work at various laboratories is underway.  相似文献   
3.
A series of anthraquinone (C(14)O(2)H(8)) derivatives has been studied by means of electron capture negative ion mass spectrometry (ECNI-MS), photoelectron spectroscopy (PES), and AM1 quantum chemical calculations. Mean lifetimes of molecular negative ions M(-.) (MNI) have been measured. The mechanism of long-lived MNI formation in the epithermal energy region of incident electrons has been investigated. A simple model of a molecule (a spherical potential well with the repulsive centrifugal term) has been applied for the analysis of the energy dependence of cross sections at the first stage of the electron capture process. It has been shown that a temporary resonance of MNI at the energy approximately 0.5 eV corresponds to a shape resonance with lifetime 1-2.10(-13) s in the f-partial wave (l = 3) of the incident electron. The next resonant state of MNI at the energy approximately 1.7 eV has been associated with the electron excited Feshbach resonance (whose parent state is a triplet npi* transition). In all cases the initial electron state of the MNI relaxes into the ground state by means of a radiationless transition, and the final state of the MNI is a nuclear excited resonance with a lifetime measurable on the mass spectrometry timescale. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
4.
5.
A bilinear time series (BLTS) model is expressed in the form of Akaike's Markovian representation in order to use the Kalman recursive estimation approach. It is shown that Akaike's Markovian representation of autoregressive moving average models of orderp and q (ARMA(p,q)) and that of the bilinear model are equivalent. This equivalence facilitates the maximum likelihood estimation of the parameters involved in the bilinear model, which otherwise is an unwieldy problem. The present approach can easily be extended to take into account missing observations  相似文献   
6.
7.
A sensitive and reliable high‐performance liquid chromatography–mass spectrometry (LC–MS/MS) was developed and validated for simultaneous quantification IC87114, roflumilast (RFM), and its active metabolite roflumilast N‐oxide (RFN) using tolbutamide as an internal standard. The analytes were extracted by using liquid–liquid extraction and separated on a reverse phase C18 column (50 mm × 3 mm i.d., 4.6 µ) using methanol: 2 mM ammonium acetate buffer, pH 4.0 as mobile phase at a flow rate 1 mL/min in gradient mode. Selective reaction monitoring was performed using the transitions m/z 398.3 > 145.9, 403.1 >186.9, 419.1 > 187.0 and 271.1 > 155.0 to quantify quantification IC87114, RFM, RFN and tolbutamide, respectively. The method was validated over the concentration range of 0.1–60 ng.mL?1 for RFM and RFN and 6 to 2980 ng.mL?1 for IC87114. Intra‐ and inter‐day accuracy and precision of validated method were within the acceptable limits of <15% at all concentrations. Coefficients of correlation (r2) for the calibration curves were >0.99 for all analytes. The quantitation method was successfully applied for simultaneous estimation of IC87114, RFM and RFN in a pharmacokinetic drug–drug interaction study in Wistar rats. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   
8.
9.
Solvent Assisted Ionization Inlet (SAII) produces ions in a heated inlet to a mass spectrometer from aqueous and aqueous/organic solutions with high sensitivity. However, the use of acid modifiers, which typically aids electrospray ionization, generally results in ion suppression in SAII. Here we demonstrate that the use of carbonation and other super-saturated gases as solution modifiers increases analyte ion abundance and reduces metal cation adduction in SAII. Carbonation is also found to enhance electrospray ionization. The mechanistic and practical utility of carbonation in mass spectrometry is addressed.   相似文献   
10.
Mechanistic arguments relative to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) address observations that predominately singly charged ions are detected. However, recently a matrix assisted laser ablation method, laserspray ionization (LSI), was introduced that can use the same sample preparation and laser as MALDI, but produce highly charged ions from proteins. In MALDI, ions are generated from neutral molecules by the photon energy provided to a matrix, while in LSI ions are produced inside a heated inlet tube linking atmospheric pressure and the first vacuum region of the mass spectrometer. Some LSI matrices also produce highly charged ions with MALDI ion sources operated at intermediate pressure or high vacuum. The operational similarity of LSI to MALDI, and the large difference in charge states observed by these methods, provides information of fundamental importance to proposed ionization mechanisms for LSI and MALDI. Here, we present data suggesting that the prompt and delayed ionization reported for vacuum MALDI are both fast processes relative to producing highly charged ions by LSI. The energy supplied to produce these charged clusters/droplets as well as their size and time available for desolvation are determining factors in the charge states of the ions observed. Further, charged droplets/clusters may be a common link for ionization of nonvolatile compounds by a variety of MS ionization methods, including MALDI and LSI.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号