首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
化学   4篇
物理学   2篇
  2007年   1篇
  2005年   1篇
  2002年   1篇
  2000年   3篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
Advances have been made recently in broadening the accessible ultrasonic absorption frequency range and improving the detectability of minor species present in solution using Raman spectroscopy. Development of chemometric techniques in these areas needs to keep pace with the improvement of these experimental methods. Refinements in the analysis of ultrasonic and Raman data based on multivariable least squares and factor analysis, respectively, are examined to investigate the kinetics of zinc thiocyanate complex formation in water. Analysis of ultrasonic absorption relaxation spectra verified that the observed process in aqueous Zn(SCN)2 involves substitution of water from the first coordination shell of Zn2+. Use of a multivariable least-squares error surface is described that enhances the reliability of assigned frequencies of ultrasonic absorption maxima. Factor analysis of Raman scattering data provided direct evidence that at least four complex species, such as Zn(SCN)+ and Zn(SCN)2, are simultaneously present in the aqueous zinc thiocyanate solutions.  相似文献   
2.
A host-guest optical sensor for the determination of aliphatic amines as exemplified by octylamine is proposed. It is based on the reversible fluorescence enhancement of heptakis(2,6-di-O-isobutyl)-β-cyclodextrin(DOB-β-CD) hosting tetraphenylporphyrin (TPP) immobilized in poly(vinyl chloride) (PVC) membrane by aliphatic amine extracted from aqueous phase into membrane phase. The optimum membrane contained 1.15 wt % TPP, 6.15 wt % DOB-β-CD as sensing reagent and other membrane materials. The fluorescence enhancement of the membrane resulted from the formation of a stable three-component complex among DOB-β-CD, TPP, and aliphatic amines. With the optimum conditions described, the fluorescence response of the sensor to octylamine shows a good correlation with the theoretically derived equation in the range 1.0 × 10–6 to 8.0 × 10–4 mol/L. The response characteristics including reversibility, response time, reproducibility and lifetime and selectivity of this optical device are also discussed in detail. This sensor has also been applied for the determination of octylamine in water samples containing interferents with satisfactory recovery.  相似文献   
3.
We present studies of novel nanocomposites of BiNi impregnated into the structure of opals as well as inverse opals. Atomic force microscopy and high resolution elemental analyses show a highly ordered structure and uniform distribution of the BiNi filler in the matrix. These BiNi-based nanocomposites are found to exhibit distinct ferromagnetic-like ordering with transition temperature of about 675 K. As far as we know there exists no report in literature on any BiNi compound which is magnetic.  相似文献   
4.
The study of phospholipid phase transitions is important for understanding drug- and protein-membrane interactions as well as other phenomena such as trans-membrane diffusion and vesicle fusion. A temperature-controlled stage on a confocal Raman microscope has allowed phase transitions in optically trapped phospholipid vesicles to be monitored. Raman spectra were acquired and analyzed using self-modeling curve resolution, a multivariate statistical analysis technique. This method revealed the subtle spectral changes indicative of sub- and pretransitions and main transitions in vesicles composed of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC). The Raman scattering results were compared to differential scanning calorimetry (DSC) experiments and found to be in good agreement. This method of observing lipid phase transition profiles requires little sample preparation and a minimal amount of lipid (相似文献   
5.
Gas-phase emission spectra of the hitherto unknown free radical BiNa have been measured in the NIR range with a Fourier transform spectrometer. The emissions were observed from a fast-flow system in which bismuth vapor in argon carrier gas was passed through a microwave discharge and mixed with sodium vapor in an observation tube. Two systems of blue-degraded bands observed in the ranges 8900-9800 and 7200-7800 cm(-1) were measured at high spectral resolution and vibrational and rotational analyses were performed. To aid in the analysis of the experimental data, a series of relativistic configuration interaction calculations has been carried out to obtain potential curves for the low-lying states of BiNa and also electric dipole transition moments connecting them. As in the isovalent BiH system, the ground state of BiNa is found to be X(3)Sigma(-) with a spin splitting of about 1769 cm(-1). The first excited state is A(3)Pi, and the observed band systems are assigned to the transitions A(3)Pi(A(2)0(+)) --> X(3)Sigma(-)(X(1)0(+), X(2)1). Comparison with earlier work on the isovalent BiH system emphasizes that the relative weakness of the varsigma MO in BiNa is responsible for qualitative differences in the electronic spectra of these two systems. Copyright 2000 Academic Press.  相似文献   
6.
A host-guest optical sensor for the determination of aliphatic amines as exemplified by octylamine is proposed. It is based on the reversible fluorescence enhancement of heptakis(2,6-di-O-isobutyl)-β-cyclodextrin(DOB-β-CD) hosting tetraphenylporphyrin (TPP) immobilized in poly(vinyl chloride) (PVC) membrane by aliphatic amine extracted from aqueous phase into membrane phase. The optimum membrane contained 1.15 wt % TPP, 6.15 wt % DOB-β-CD as sensing reagent and other membrane materials. The fluorescence enhancement of the membrane resulted from the formation of a stable three-component complex among DOB-β-CD, TPP, and aliphatic amines. With the optimum conditions described, the fluorescence response of the sensor to octylamine shows a good correlation with the theoretically derived equation in the range 1.0 × 10–6 to 8.0 × 10–4 mol/L. The response characteristics including reversibility, response time, reproducibility and lifetime and selectivity of this optical device are also discussed in detail. This sensor has also been applied for the determination of octylamine in water samples containing interferents with satisfactory recovery. Received: 21 November 1999 / Revised: 10 January 2000 / Accepted: 15 January 2000  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号