排序方式: 共有37条查询结果,搜索用时 31 毫秒
1.
2.
3.
RITVA LINDBERG GORAN SUNDHOLM JOHAN SJö BLOM PETRI AHONEN ESKO I. KAUPPINEN 《Journal of Dispersion Science and Technology》2013,34(1-2):715-722
The zeta-potentials of silica, copper, platinum and gold particles have been measured as a function of pH. The isoelectric points were found to be at pH 3.0, 5.8, 3.0 and 3.5, respectively. In the pH range 3.0 to 5.8 copper and silica particles are oppositely charged and accordingly the coating of silica with copper particles could be demonstrated. In the case of gold and platinum the sign of the charge is such that direct adhesion to silica particles cannot be expected and this was also demonstrated in the case of platinum. 相似文献
4.
van Enk SJ 《Physical review letters》2000,84(4):789; author reply 790
5.
Douglas McHugh Sherry SJ Hu Neta Rimmerman Ana Juknat Zvi Vogel J Michael Walker Heather B Bradshaw 《BMC neuroscience》2010,11(1):44
Background
Microglia provide continuous immune surveillance of the CNS and upon activation rapidly change phenotype to express receptors that respond to chemoattractants during CNS damage or infection. These activated microglia undergo directed migration towards affected tissue. Importantly, the molecular species of chemoattractant encountered determines if microglia respond with pro- or anti-inflammatory behaviour, yet the signaling molecules that trigger migration remain poorly understood. The endogenous cannabinoid system regulates microglial migration via CB2 receptors and an as yet unidentified GPCR termed the 'abnormal cannabidiol' (Abn-CBD) receptor. Abn-CBD is a synthetic isomer of the phytocannabinoid cannabidiol (CBD) and is inactive at CB1 or CB2 receptors, but functions as a selective agonist at this Gi/o-coupled GPCR. N-arachidonoyl glycine (NAGly) is an endogenous metabolite of the endocannabinoid anandamide and acts as an efficacious agonist at GPR18. Here, we investigate the relationship between NAGly, Abn-CBD, the unidentified 'Abn-CBD' receptor, GPR18, and BV-2 microglial migration. 相似文献6.
Roughness measurement of metallic surfaces based on the laser speckle contrast method 总被引:2,自引:0,他引:2
A method of measuring surface roughness of flat lapped, ground and polished metallic surfaces, by the far-field speckle contrast method is presented in this paper. The laser speckle contrast technique depends on the existence of an approximately linear relationship between the speckle contrast and the roughness of the illuminated surface. Initially it was shown that the linear relationship existed up to 0.1 μm Ra (centre-line average) roughness using Helium–Neon light, after which a saturation effect was observed. The effect of varying the incident angle of illumination was investigated with a view to extending the measurement range. The use of high incident angles of illumination has been found to increase the surface roughness range up to 0.4 μm measurement Ra. 相似文献
7.
Toal SJ Jones KA Magde D Trogler WC 《Journal of the American Chemical Society》2005,127(33):11661-11665
Colloidal suspensions of 3-aminopropylmethyl(tetraphenyl)silole nanoparticles can be used as selective chemosensors for carcinogenic chromium(VI) analyte. Methylhydrosilole is functionalized by hydrosilation of allylamine, and the colloid is prepared by the rapid addition of water to a THF solution of the silole. The method of detection is through electron-transfer quenching of the fluorescence of the silole colloid (lambda(em) = 485 nm at 360 nm excitation) by the analytes, with hundred parts per billion detection limits. Stern-Volmer plots are linear up to 10 ppm in the case of chromium, but exhibit saturation behavior near 5-10 ppm for arsenic. Dynamic light scattering experiments and AFM measurements show the particle sizes to be around 100 nm in diameter and dependent on solvent composition, with a particle size dispersity of +/-25%. The fluorescence lifetimes of the silole in solution and colloid are approximately 31 ps and approximately 4.3 ns, respectively, while the silole has a lifetime of 6 ns in the bulk solid. A minimum volume fraction of 80% water is necessary to precipitate the colloid from THF, and the luminescence continues to rise with higher water fractions. Colloids in a pH 7 phosphate-buffered suspension show both higher sensitivity and greater selectivity (100-fold) for CrO4(2-) detection than for other oxoanion interferents, NO3-, NO2-, SO4(2-), and ClO4-. 相似文献
8.
9.
10.
We report a simple, compact electronic speckle-pattern interferometer (ESPI) incorporating holographic optical elements (HOEs) for the study of out-of-plane vibration. Reflection and transmission HOEs provide reference and object beams in the interferometer. The alignment difficulties with conventional ESPI systems are minimized using HOEs. The time-average ESPI subtraction method is used to generate the fringe pattern and remove background speckle noise by introducing a phase shift between consecutive images. The amplitude and phase maps are obtained using path-difference modulation. 相似文献