首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
化学   5篇
数学   1篇
  2022年   1篇
  2013年   1篇
  2006年   1篇
  2003年   3篇
排序方式: 共有6条查询结果,搜索用时 62 毫秒
1
1.
We have designed fluorescent "through-bond energy-transfer cassettes" that can harvest energy of a relatively short wavelength (e.g., 490 nm), and emit it at appreciably longer wavelengths without significant loss of intensity. Probes of this type could be particularly useful in biotechnology for multiplexing experiments in which several different outputs are to be observed from a single excitation source. Cassettes 1-4 were designed, prepared, and studied as model systems to achieve this end. They were synthesized through convergent routes that feature coupling of specially prepared fluorescein- and rhodamine-derived fragments. The four cassettes were shown to emit strongly, with highly efficient energy transfer. Their emission maxima cover a broad range of wavelengths (broader than the four dye cassettes currently used for most high-throughput DNA sequencing), and they exhibit faster energy-transfer rates than a similar through-space energy-transfer cassette. Specifically, energy-transfer rates in these cassettes is around 6-7 ps, in contrast to a similar through-space energy-transfer system shown to have a decay time of around 35 ps. Moreover, the cassettes are considerably more stable to photobleaching than fluorescein, even though they each contain fluorescein-derived donors. This was confirmed by bulk fluorescent measurements, and in single-molecule-detection studies. Modification of a commercial automated DNA-sequencing apparatus to detect the emissions of these four energy-transfer cassettes enabled single-color dye-primer sequencing.  相似文献   
2.
In many problems involving generalized linear models, the covariates are subject to measurement error. When the number of covariates p exceeds the sample size n, regularized methods like the lasso or Dantzig selector are required. Several recent papers have studied methods which correct for measurement error in the lasso or Dantzig selector for linear models in the p > n setting. We study a correction for generalized linear models, based on Rosenbaum and Tsybakov’s matrix uncertainty selector. By not requiring an estimate of the measurement error covariance matrix, this generalized matrix uncertainty selector has a great practical advantage in problems involving high-dimensional data. We further derive an alternative method based on the lasso, and develop efficient algorithms for both methods. In our simulation studies of logistic and Poisson regression with measurement error, the proposed methods outperform the standard lasso and Dantzig selector with respect to covariate selection, by reducing the number of false positives considerably. We also consider classification of patients on the basis of gene expression data with noisy measurements. Supplementary materials for this article are available online.  相似文献   
3.
[structure: see text] Regioisomerically pure bromo-substituted rhodamine derivatives (bromorosamines) were prepared via microwave-accelerated condensation reactions followed by oxidation with chloranil. Reaction optimization was conveniently performed by monitoring UV absorptions attributed to the product.  相似文献   
4.
Syntheses of a unique set of energy transfer dye labeled nucleoside triphosphates, compounds 1-3, are described. Attempts to prepare these compounds were only successful if the triphosphorylation reaction was performed before coupling the dye to the nucleobase, and not the other way around. Compounds were prepared as both the 2'-deoxy (a) and 2',3'-dideoxy- (b) forms. They feature progressively longer rigid conjugated linkers connecting the nucleobase and the hydroxyxanthone moiety. UV spectra of the parent nucleosides 12-14 show that as the length of the linker increases so does the absorption of the donor in the 320-330 nm region, but with relatively little red-shift of the maxima. Fluorescence spectra of the same compounds show that radiation in the 320-330 nm region results in predominant emission from the fluorescein. When the linker is irradiated at 320 nm, the only significant emission observed corresponds to the hydroxyxanthone part of the molecules at 520 nm; this corresponds to an effective Stokes' shift of 200 nm. As the absorption at 320-330 nm by the linker increases with length, so does the intensity of the fluorescein emission. A gel assay was used to gauge relative incorporation efficiencies of compounds 1-3, dTTP, ddTTP, and 6-TAMRA-ddTTP. Throughout, the thermostable polymerase TaqFS was used, as it is the one most widely applied in high throughput DNA sequencing. This assay showed that only compounds 3 were incorporated efficiently; these have the longest linkers. Of these, the 2'-deoxy nucleoside 3 a was incorporated and did not prevent the polymerase from extending the chain further. The 2',3'-dideoxy nucleoside 3 b was incorporated only about 430 times less efficiently than ddTTP under the same conditions, and caused chain termination. The implications of these studies on modified sequencing protocols are discussed.  相似文献   
5.
Through-bond energy transfer cassettes based on a fluorescein donor component electronically conjugated to rhodamine-like acceptors have been designed and synthesized. They absorb strongly at 488 nm (Ar-laser emission) and efficiently transfer the energy to the acceptor component that emits strongly. Further, the cassettes are more stable to photobleaching than fluorescein, making them potentially more suitable for single-molecule detection methods than fluorescein itself. These studies form the basis for improved detection of chain-terminated DNA in high-throughput sequencing and other applications in biotechnology.  相似文献   
6.
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号