首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   4篇
  2018年   2篇
  2013年   1篇
  2011年   1篇
排序方式: 共有4条查询结果,搜索用时 31 毫秒
1
1.
Firstly, poly[phenyl thiadiazole methacrylamide-co-divinylbenzene-co-2-acrylamido-2-methylpropane sulfonic acid] (PTMAAm-co-DVB-co-AMPS), a new polymer resin was synthesized. This polymer resin was characterized by elemental analyzer, X-ray diffractometer, scanning electron microscope (SEM) and IR spectrometer. The glass column packed with the synthesized polymer resin was used for solid phase extraction (SPE). At the same time, the analytes were separated and preconcentrated from various water, dried vegetables samples and standard reference material (CRM) with SPE and determined by flame atomic absorption spectrometer (FAAS). The experimental conditions of this method such as pH, flow rates of sample, flow rates of eluent, type / concentration / volume of eluent, sample volume and matrix ions were examined. The limits of detection (µg L?1) were calculated (3s) 0.9 for Mn(II), 1.4 for Cd(II), Co(II) and Zn(II), 1.5 for Cr(III), 2.2. for Cu(II), 1.9 for Pb(II),1.5 for Ni(II) and 1.9 for Fe(III) (n = 21). The low relative standard deviation, ≤ 2% (n = 11) and preconcentration factor as 75 for analytes were obtained.  相似文献   
2.
A rapid and simple on-line method is described for the determination of Au(III) in various samples. The method is based on the sorption of gold(III) on Lewatit MonoPlus TP207 chelating resin including the iminodiacetate group, which is used as sorbent material and packed in a minicolumn. The chemical variables such as the pH of the sample solution, eluent type, interfering ions and concentrations of reagents, and instrumental variables such as sample loading volume, reagents flow rates, and tubing length, which affect the efficiency of the method were studied and optimised. Au(III) was sorbed on the chelating resin, from which it could be eluted with 3 mol L?1 HCl, and then introduced directly to the nebuliser-burner system of FAAS. The limit of detection of the method was 0.2 µg L?1 while the relative standard deviation was <4.0% for 20 µg L?1 Au(III) concentration. The preconcentration factor was found to be 106 while the optimised sample volume was 15.3 mL. The accuracy of the method was verified by analysing the certified reference material. The developed method was applied successfully for the determination of gold in different samples with satisfactory results.  相似文献   
3.
The coupling reaction of N-methylindole with alkyl and aryl phosphonate is described. The reaction works in the presence of 10 mol % of indium triflate and furnished bis(indolyl)methane phosphonates in good yield and high selectivity.  相似文献   
4.
In this work, a new polymer resin with a functional groups capable of holding trace metals has been synthesized. The structure of polymer resin has been examined by BET-N2 method analyzer, IR spectrometer, scanning electron microscope (SEM) and elemental microanalyser. The synthesized polymer resin was used for the simultaneous separation and preconcentration of the trace metals from various tea and herbal plants samples. After extraction process, flame atomic absorption spectrometry (FAAS) was used to determine the trace metals. The analytical parameters and solid phase extraction (SPE) performance such as pH, sample volume, flow rates of sample, flow rates of eluent, concentration, volume and type of eluent and effect of interference ions, were investigated. The limits of detection (DL) of the SPE procedure for trace metals, were calculated to be (3s) in the range of 0.9?4.0 μg L?1 (n = 21) and the factors of preconcentration (PF) were obtained at 200 for Cd, Co, Cu, Fe, Ni and Zn, and at 50 for Cr, Mn and Pb ions and the relative standard deviation (RSD) at ≤ 2% (n = 11).  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号