首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   71篇
  免费   1篇
化学   71篇
物理学   1篇
  2022年   2篇
  2018年   1篇
  2016年   6篇
  2015年   5篇
  2014年   5篇
  2013年   8篇
  2012年   1篇
  2011年   5篇
  2010年   2篇
  2009年   2篇
  2008年   4篇
  2007年   8篇
  2006年   3篇
  2005年   2篇
  2004年   2篇
  2003年   2篇
  2002年   3篇
  2001年   1篇
  1999年   1篇
  1997年   1篇
  1996年   1篇
  1995年   1篇
  1994年   1篇
  1992年   1篇
  1989年   1篇
  1988年   1篇
  1986年   2篇
排序方式: 共有72条查询结果,搜索用时 328 毫秒
1.
2.
One of the difficulties frequently encountered when studying acid–base equilibria with NMR spectroscopy is the labile behaviour of the measured signal, which hinders the application of bilinear multivariate data analysis methods. In this work, a mathematical transformation is proposed for the conversion of NMR labile signals to inert signals, which make possible the application of multivariate data analysis methods, based on bilinear data models. The procedure has been applied to the analysis of NMR data corresponding to the acid–base equilibria of nucleotides dCMP and dGMP. Both hard-modelling (EQUISPEC) and soft-modelling (MCR-ALS) approaches have been applied for the analysis and resolution of transformed bilinear NMR data matrices.  相似文献   
3.
Principal component analysis is applied to the study of multiple equilibria systems based on copper (Il) ion with salicylate and mono-, di- or triethanolamine as ligands. A procedure based on evolving factor analysis is described which allows the model-free determination of distribution plots and of the individual spectra of the various species formed in the course of a spectrophotometric titration. The results are compared with those obtained by using least-squares methods.  相似文献   
4.
The performance of five of the best-known computer programs LETAGROP, SCOGS, MINIQUAD, SUPERQUAD and ESTA, is critically discussed. All these programs are based on least-squares refinement procedures but differ in some important aspects: (a) the definition of the residuals function; (b) the minimization procedure; (c) the statistical and weighting parameters. Each of these aspects is evaluated and the programs are compared on this basis.  相似文献   
5.
6.
Simultaneous anodic stripping voltammetric determination of Pb and Cd is restricted on gold electrodes as a result of the overlapping of these two peaks. This work describes the quantitative determination of a binary mixture system of Pb and Cd, at low concentration levels (up to 15.0 and 10.0 µg L?1 for Pb and Cd, respectively) by differential pulse anodic stripping voltammetry (DPASV; deposition time of 30 s), using a green electrode (vibrating gold microwire electrode) without purging in a chloride medium (0.5 M NaCl) under moderate acidic conditions (HCl 1.0 mM), assisted by chemometric tools. The application of multivariate curve resolution alternating least squares (MCR‐ALS) for the resolution and quantification of both metals is shown. The optimized MCR‐ALS models showed good prediction ability with concentration prediction errors of 12.4 and 11.4 % for Pb and Cd, respectively. The quantitative results obtained by MCR‐ALS were compared to those obtained with partial least squares (PLS) and classical least squares (CLS) regression methods. For both metals, PLS and MCR‐ALS results are comparable and superior to CLS. For Cd, as a result of the peak shift problem, the application of CLS was unsuitable. MCR‐ALS provides additional advantage compared to PLS since it estimates the pure response of the analytes signal. Finally, the built up multivariate calibration models, based either in MCR‐ALS or PLS regression, allowed to quantify concentrations of Pb and Cd in surface river water samples, with satisfactory results.  相似文献   
7.
This study focuses on the development and extension of Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) to the analysis of four-way datasets. The proposed extension of the MCR-ALS method with non-negativity and the newly developed quadrilinear constraints can be exploited to summarize and manage huge multidimensional datasets and resolve their four way component profiles. In this study, its application is demonstrated by analyzing a four-way data set obtained in a long term environmental monitoring study (15 sampling sites × 9 variables × 12 months × 7 years) belonging to the Yamuna River, one of the most polluted rivers of India and the largest tributary of the Ganges river. MCR-ALS resolved pollution profiles described appropriately the major observed changes on pH, organic pollution, bacteriological pollution and temperature, along with their spatial and temporal distribution patterns for the studied stretch of Yamuna River. Results obtained by MCR-ALS have also been compared with those obtained by another multi-way method, PARAFAC. The methodology used in this study is completely general and it can be applied to other multi-way datasets.  相似文献   
8.
Multivariate Curve Resolution Alternating Least Squares (MCR-ALS) can analyze three-way data under the assumption of a trilinear model using the trilinearity constraint. However, the rigid application of this constraint can produce unrealistic solutions in practice due to the inadequacy of the analyzed data to the characteristics and requirements of the trilinear model. Different methods for the relaxation of the trilinear model data requirements have been proposed, like in the PARAFAC2 and in the direct non-trilinear decomposition (DNTD) methods. In this work, the trilinearity constraint of MCR-ALS is adapted to different data scenarios where the profiles of all or some of the components of the system are shifted (not equally synchronized) or even change their shape among different slices in one of their data modes. This adaptation is especially useful in gas and liquid chromatography (GC and LC) and in Flow Injection Analysis (FIA) with multivariate spectroscopic detection. In a first data example, a synthetic LC-DAD dataset is built to investigate the possibilities of the proposed method to handle systematic changes (shifts) in the retention times of the elution profiles and the results are compared with those obtained using alternative methods like ATLD, PARAFAC, PARAFAC2 and DNTD. In a second data example, multiple wine samples were simultaneously analyzed by GC-MS where elution profiles presented large deviations (shifts) in their peak retention times, although they still preserve the same peak shape. Different modelling scenarios are tested and the results are also compared. Finally, in the third example, sample mixtures of acid compounds were analyzed by FIA under a pH gradient and monitored by UV spectroscopy and also examined by different chemometric methods using a different number of components. In this case, however, the departure of the trilinear model comes from the acid base speciation of the system depending on the pH more than from the shifting of the FIA diffusion profiles.  相似文献   
9.
Toxicity assays applied to wastewater treatment   总被引:1,自引:0,他引:1  
The utility and validity of toxicity tests for monitoring of wastewater treatment have been assessed. The evaluated acute toxicity tests have been Vibrio fischeri, Selenastrum capricornotum and Daphnia magna tests. The validation studies indicated that the acute toxicity tests can be considered as high sensitivity analytical tools to detect common environmental concentrations of the pollutants at concentration levels as low as ng l−1. The toxicity tests showed to have discriminatory ability to distinguish between different degrees of toxicity, and the toxic specificity of the compounds on target organisms. Synergistic, additive or antagonistic effects were evaluated indicating the capacity of the toxicity test to assess the combined effects of chemicals in wastewaters. The reproducibility of these tests, calculated as relative standard deviation, is acceptable in the range of 5-22.3%. The application of multivariate date analysis proved that toxicity and chemical measures are complementary analytical tools for monitoring of wastewaters quality. The toxicity tests are useful analytical tools for screening of chemical analysis and as an early warning system to monitor the treatment of WWTPs. The use of single toxicity test or battery of tests is the best approach to evaluate the risk because they are reliable indices of the toxic impact of effluents in the aquatic environment. The toxicity tests were applied in the quality control of different European WWTPs.  相似文献   
10.
MCR-ALS is a resolution method that has been applied in many different fields, such as process analysis, environmental data and, recently, hyperspectral image analysis. In this context, the algorithm provides the distribution maps and the pure spectra of the image constituents from the sole information in the raw image measurement. Based on the distribution maps and spectra obtained, additional information can be easily derived, such as identification of constituents when libraries are available or quantitation within the image, expressed as constituent signal contribution. This work summarizes first the protocol followed for the resolution on two examples of kidney calculi, taken as representations of images with major and minor compounds, respectively. Image segmentation allows separating regions of images according to their pixel similarity and is also relevant in the biomedical field to differentiate healthy from non-healthy regions in tissues or to identify sample regions with distinct properties. Information on pixel similarity is enclosed not only in pixel spectra, but also in other smaller pixel representations, such as PCA scores. In this paper, we propose the use of MCR scores (concentration profiles) for segmentation purposes. K-means results obtained from different pixel representations of the data set are compared. The main advantages of the use of MCR scores are the interpretability of the class centroids and the compound-wise selection and preprocessing of the input information in the segmentation scheme.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号