全文获取类型
收费全文 | 179篇 |
免费 | 4篇 |
国内免费 | 1篇 |
专业分类
化学 | 153篇 |
晶体学 | 2篇 |
力学 | 1篇 |
数学 | 9篇 |
物理学 | 19篇 |
出版年
2024年 | 3篇 |
2023年 | 1篇 |
2022年 | 5篇 |
2021年 | 9篇 |
2020年 | 8篇 |
2019年 | 5篇 |
2018年 | 13篇 |
2017年 | 10篇 |
2016年 | 8篇 |
2015年 | 11篇 |
2014年 | 5篇 |
2013年 | 25篇 |
2012年 | 19篇 |
2011年 | 15篇 |
2010年 | 6篇 |
2009年 | 9篇 |
2008年 | 7篇 |
2007年 | 4篇 |
2006年 | 7篇 |
2005年 | 3篇 |
2004年 | 2篇 |
2003年 | 2篇 |
2002年 | 4篇 |
2001年 | 2篇 |
1998年 | 1篇 |
排序方式: 共有184条查询结果,搜索用时 125 毫秒
1.
The ability of titanium(IV) chloride as a catalyst to promote the Pechmann condensation reaction with a range of phenols and β-keto esters is described.The reaction was carried out by addition of TiCl4 to a mixture of the phenol and the β-keto ester with thorough stirring in the absence of a solvent and represents an improvement on the classical Pechmann conditions. The yields of coumarins obtained via this novel protocol were significantly higher than those using the conventional method and the reaction duration was reduced to a few minutes or even a few seconds. 相似文献
2.
Mojtaba Shamsipur Tahereh Poursaberi Morteza Hosseini Naader Alizadeh Mohammad Reza Ganjali 《Analytica chimica acta》2004,501(1):55-60
A highly sensitive and selective fluorimetric optode membrane for the determination of ultra trace amounts of Ni2+ ions was prepared. The plasticized PVC-membrane incorporating potassium tetrakis(p-chlorophenyl)borate (KTpClPB) and 2,5-thiophenylbis(5-tert-butyl-1,3-benzexazole) (TTBB), as a highly fluorescent chromoionophore, displays a calibration response for Ni2+ ions over a wide concentration range of 1.0×10−3 to 1.0×10−8 M. It has a relatively fast response of <40 s. In addition to high stability and reproducibility, and relatively long working lifetime, the sensor possesses good selectivity for nickel ions over several common diverse ions. The fluorescence signal of the optode membrane can be easily recovered by immersion in EDTA solution. The optode was applied successfully to the determination of traces of Ni2+ ion in edible oil and a wastewater sample from nickel electroplating industries. 相似文献
3.
J. Edward Schneider Jr. Tahereh Tabatabaie Lindsay Maidt Renee Horning Smith Xuan Nguyen Quentin Pye Robert A. Floyd 《Photochemistry and photobiology》1998,67(3):350-357
A spectrum of oxidative lesions was observed in a bacteriophage-based model system that is very sensitive to the photodynamic activity of selected dyes. When suspensions of the intact bacteriophage Qβ were exposed to methylene blue plus light (MB+L), inactivating events, or "hits" occurred that were oxygen-dependent and that were associated with the formation of several specific lesions: (1) carbonyl moieties on proteins, (2) 8-oxo-7,8-dihydroguanine (8-oxoGua), and (3) single-strand breaks (ssb) in the RNA genome and (4) RNA-protein crosslinks. Formation of carbonyl groups associated with protein in the Qβ phage preparation correlated positively with photoinactivation of the phage with increasing doses of either of the sensitizers MB or rose bengal. Strand breaks in the Qβ genomic RNA were observable at high MB concentrations but appeared not to be significant at the lower concentrations of MB, as full-length Qβ RNA was observable well beyond the 99% inactivation point in MB dosage. It was shown that the number of 8-oxoGua lesions were unlikely to be sufficient to account for the number of lethal events. Following exposure to MB+L, crosslink formation between Qβ RNA and protein was observed by virtue of the location of RNA at the interface of phenol-aqueous extractions of phage suspensions. A significant increase over background of RNA-protein complexes (including full-length Qβ RNA) was observed at the lowest concentration of MB tested (0.5 μ M ), which corresponded roughly to an average of 2 lethal hits per phage or approximately 13% survival compared to the zero MB control (100% survival). Due to its close correlation with Qβ inactivation and its expected lethality, RNA-protein crosslink formation may be important as an inactivating lesion in bacteriophage Qβ following MB+L exposure. 相似文献
4.
Abbas Shockravi Hashem Shargi Hassan Valizadeh Majid M. Heravi 《Phosphorus, sulfur, and silicon and the related elements》2013,188(11):2555-2559
An efficient synthesis of 3-substituted coumarins under solventless system is described. 相似文献
5.
A. Habibi H. S. Ghorbani G. Bruno H. A. Rudbari Y. Valizadeh 《Crystallography Reports》2013,58(7):1084-1087
The crystal structure of 1-Methyl-3-([2,2-dimethyl-4,6-dioxo-1,3-dioxane-5-ylidene]methyl)urea (C9H12N2O5) has been determined by single crystal X-ray diffraction analysis. The crystals are monoclinic, a = 5.3179(2), b = 18.6394(6), c =10.8124(3) Å, β = 100.015(2)°, Z = 4, sp. gr. P21/c, R = 0.0381 for 2537 reflections with I > 2σ(I). Except for C(CH3)2 group, the molecule is planar. The structure is stabilized by inter- and intramolecular N-H...O hydrogen bonds and weak C-H...O interactions. 相似文献
6.
Mohammad Yousefi Elham Noori Davood Ghanbari Masoud Salavati-Niasari Tahereh Gholami 《Journal of Cluster Science》2014,25(2):397-408
In this work, poly vinyl alcohol–ZnO nanocomposites were synthesized via two different in situ and ex-situ methods. In ex-situ, at first zinc oxide nanostructures were synthesized by one-step precipitation reaction between zinc acetate and sodium hydroxide. The effect of different surfactants such as poly vinyl pyrrolidone, poly vinyl alcohol and poly ethylene glycol on the morphology of ZnO nanostructures was investigated. Nanostructures were characterized by X-ray diffraction, scanning electron microscopy. The influence of ZnO nanostructures on the flame retardancy of the poly vinyl alcohol matrix was studied using underwriter laboratories UL-94 analysis. 相似文献
7.
8.
We consider a rotating Bose-Einstein condensate in an optical lattice in the regime in which the system Hamiltonian can be mapped onto a Josephson junction array. In an approximate scheme where the couplings are assumed uniform, the ground state energy is formulated in terms of the vortex configuration. Application of the method for the ladder case presented and the results are compared with Monte-Carlo method. 相似文献
9.
Nanoparticles of organosilane-based nitrite ionic liquid immobilized on silica, 1-butyl-3-methylimidazolium nitrite, and 1-(3-trimethoxysilylpropyl)-3-methylimidazolium nitrite were used as effective reagents for the preparation of benzotriazole derivatives from 1,2-diaminobenzenes at room temperature under mild solvent-free conditions. These ionic liquids play as nitrosonium sources in this procedure.1,2-Diaminobenzene derivatives have been treated with ionic liquids to give the related diaminobenzenes in very good to excellent yields in short reaction times.
Supplementary materials are available for this article. Go to the publisher's online edition of Synthetic Communications® for the full experimental and spectral details. 相似文献
10.
Tahereh Sadeghcheh Mohammad Saber Tehrani Hakim Faraji Parviz Aberoomand Azar Masoumeh Helalizadeh 《Journal of separation science》2022,45(7):1362-1373
A sensitive method based on liquid chromatography combined with a diode array detector was developed and validated to simultaneously determine tamoxifen, and its active metabolites N-desmethyltamoxifen, 4-hydroxytamoxifen, and endoxifen in human plasma samples. The green and sustainable vortex-assisted dispersive liquid-phase microextraction technique based on the natural hydrophobic deep eutectic solvent was used for the extraction and preconcentration of the analytes. Chemometrics and multivariate analysis were used to optimize the independent variables including the type and volume of deep eutectic solvent, extraction time, and ionic strength. Under optimal conditions, calibration curves were linear in a suitable range with the lower limits of quantification (0.8–10.0 μg/L), which covered the relevant concentrations of the analytes in plasma samples for a clinical study. Intra- and interday precision evaluated at three concentrations for the analytes were lower than 8.2 and 12.1%, respectively. Accuracy was in the range of 94.9–104.7%. The applicability of the developed method on human plasma samples illustrated the range 45.1–72.8, 98.4–128.3, 0.9–1.2, and 2.7–6.1 μg/L for tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen, and endoxifen, respectively. The validated method can be effective for the pharmacokinetics, pharmacodynamics, and therapeutic drug monitoring studies of tamoxifen and its main metabolites in biological fluids. 相似文献