首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   22篇
  免费   0篇
  国内免费   1篇
化学   5篇
力学   1篇
数学   17篇
  2008年   1篇
  2007年   1篇
  2006年   2篇
  2005年   1篇
  2004年   1篇
  2000年   1篇
  1996年   1篇
  1995年   1篇
  1986年   3篇
  1984年   2篇
  1981年   1篇
  1979年   1篇
  1977年   3篇
  1976年   1篇
  1975年   1篇
  1974年   1篇
  1969年   1篇
排序方式: 共有23条查询结果,搜索用时 31 毫秒
1.
The storage stability of the occupationally frequently occurring compounds, methylethylketone, methylisobutylketone, benzene, toluene, tetrachloroethylene, n-butylacetate, -pinene, β-pinene, limonene and n-decane, has been investigated on the adsorbents Tenax TA, Chromosorb 106 and Carbotrap using thermally desorbable tube type samplers, commonly utilized in ambient and workroom atmospheric measurements. Fifty and 500 ng of each compound were loaded on the various adsorbents tubes, stored at both ambient (20 °C) and refrigerated (4 °C) temperatures and analysed by means of thermal gas chromatography with mass spectrometric detection on days 0, 7, 14 and 28 after exposure. A 90% storage recovery was chosen as acceptance criteria for storage stability, and statistical testing by Student's t-test, analysis of variance and Bonferroni post hoc tests were employed to investigate the effect of the categorical variables storage time, storage temperature and analyte loading on the different adsorbents. Chromosorb 106 showed the overall best behaviour with recoveries of 90% or better for all analytes during the 28-day test period. Tenax TA and Carbotrap yielded lower recoveries and were more influenced by variations in storage time, storage temperature and analyte loading. Refrigerated temperatures were best avoided for storage on Tenax TA, but may increase the recovery of some compounds on Carbotrap (e.g. n-butylacetate). The blank build-up on the adsorbents was also investigated, and Carbotrap and Tenax TA showed no signs of artefact development over time. Chromosorb 106, however, contained inherently more artefacts that build up over time, which in spite of the excellent storage capability, may limit its use in field studies where long storage times are normal.  相似文献   
2.
Methodology for personal occupational exposure assessment of airborne trialkyl and triaryl organophosphates originating from hydraulic fluids by active combined aerosol and vapor sampling at 1.5L/min is presented. Determination of the organophosphates was performed by gas chromatography-mass spectrometry. Combinations of adsorbents (Anasorb 747, Anasorb CSC, Chromosorb 106, XAD-2 and silica gel) with an upstream cassette with glass fiber or PTFE filters and different desorption/extraction solvents (CS(2), CS(2)-dimethylformamide (50:1, v/v), toluene, dichloromethane, methyl-t-butyl ether and methanol) have been evaluated for optimized combined vapor and aerosol air sampling of the organophosphates tri-isobutyl, tri-n-butyl, triphenyl, tri-o-cresyl, tri-m-cresyl and tri-p-cresyl phosphates. The combination of Chromosorb 106 and 37 mm filter cassette with glass fiber filter and dichloromethane as desorption/extraction solvent was the best combination for mixed phase air sampling of the organophosphates originating from hydraulic fluids. The triaryl phosphates were recovered solely from the filter, while the trialkyl phosphates were recovered from both the filter and the adsorbent. The total sampling efficiency on the combined sampler was in the range 92-101% for the studied organophosphates based on spiking experiments followed by pulling air through the sampler. Recoveries after 28 days storage were 98-102% and 99-101% when stored at 5 and -20 degrees C, respectively. The methodology was further evaluated in an exposure chamber with generated oil aerosol atmospheres with both synthetic and mineral base oils with added organophosphates in various concentrations, yielding total sampling efficiencies in close comparison to the spiking experiments. The applicability of the method was demonstrated by exposure measurements in a mechanical workshop where system suitability tests are performed on different aircraft components in a test bench, displaying tricresyl phosphate air concentrations of 0.024 and 0.28 mg/m(3), as well as during aircraft maintenance displaying tri-n-butyl phosphate air concentrations of 0.061 and 0.072 mg/m(3).  相似文献   
3.
Dahlquist proved that under the condition of zero-stability the order of lineark-step methods is bounded by 2[(k+2)/2]. In the present paper we provide a proof of this celebrated result by using the theory of order stars. Dedicated to Germund Dahlquist on his 60th birthday; the initial value and global maximum of our research.  相似文献   
4.
A temperature-programmed packed capillary LC method with large-volume injection on-column focusing has been developed for screening and determination of 1-(2-methoxyphenyl)piperazine derivatives of airborne toluene-2,4-diisocyanate, toluene-2,6-diisocyanate, hexamethylenediisocyanate and methylenebisphenyl-4,4-diisocyanate, based on sampling methods described in MDHS 25/3. Injection volumes up to 100 microl were successfully loaded onto the 250x0.32 mm I.D. capillary column packed with 3 microm Hypersil ODS particles. The isocyanate derivatives were loaded at 10 degrees C and eluted by a three-step temperature program starting at 10 degrees C for 10 min, followed by a temperature ramp of 2.5 degrees C min(-1) to 45 degrees C and then 9.9 degrees C min(-1) to 90 degrees C. The mobile phase consisted of acetonitrile-acetate buffer (3% triethylamine, pH 4.5) (45:55, v/v). The isocyanate derivatives were dissolved in acetonitrile-acetate buffer (3% triethylamine, pH 4.5) (30:70, v/v) to achieve sufficient focusing. The concentration limit of detection of the individual derivatives utilizing an "U" shaped flow cell with a 8.0 mm light path and an injection volume of 100 microl was 44, 87, 43 and 210 pg ml(-1) for toluene-2,6-diisocyanate, hexamethylenediisocyanate, toluene-2,4-diisocyanate and methylenebisphenyl-4,4-diisocyanate, respectively. Within the investigated concentration range, 10-500 ng ml(-1), the linear calibration curves gave correlation coefficients ranging from 0.994 to 0.998. The repeatability of the method with regard to retention time and peak height ranged from 0.3 to 1.1% and 1.1 to 2.3% (n=9) relative standard deviation, respectively. The average recovery of the method, with regard to toluene-2,4-diisocyanate, was 97.7+/-1.6% (n=9).  相似文献   
5.
LetR n/m(z∶γ)=P n(z∶γ)/(1?γz) m be a rational approximation to exp (z),zC, of ordern for all real positiveγ. In this paper we show there exists exactly one value ofγ in each of min(n+1,m) interpolation intervals such that the uniform error overR ? is at a local minimum.  相似文献   
6.
In this paper we discuss the automatic switch between modified Newton iteration with the Jacobian not equal zero and fix-point iteration, i.e. the Jacobian equal zero. The switching strategy is based on the ratio between the norm of the displacement and the norm of the residual. Several examples are discussed both from non-stiff and stiff systems. These examples show that our strategy is working as predicted.This work was supported by NATO Research Grant Programme, project RG 096.80 and by National Sciences and Engineering Research Council of Canada, Grants: A1244, A3597, A4076, A8111, A8239, A8639.  相似文献   
7.
8.
Given a parametrised weight function (x,) such that the quotients of its consecutive moments are Möbius maps, it is possible to express the underlying biorthogonal polynomials in a closed form [5]. In the present paper we address ourselves to two related issues. Firstly, we demonstrate that, subject to additional assumptions, every such obeys (inx) a linear differential equation whose solution is a generalized hypergeometric function. Secondly, using a generalization of standard divided differences, we present a new explicit representation of the underlying biorthogonal polynomials.  相似文献   
9.
A method based on column switching packed capillary liquid chromatography electrospray mass spectrometry has been developed for the determination of the adduct glyoxal-deoxyguanosine, a biomarker candidate for the assessment of glyoxal exposure, in DNA hydrolysate solutions. Microgram amounts of DNA were isolated and enzymatically hydrolyzed to deoxyribonucleosides, prior to ultrafiltration and subsequent dilution to a sample solution consisting of water-acetonitrile-formic acid (98 : 2 : 0.2, v/v). The sample solution was loaded onto a 1 mm I.D. x 5 mm Hypercarb (5 mum) porous graphitic carbon trap column for analyte enrichment using an injection volume of 200 mul, and was subsequently back-flushed onto a 0.30 mm I.D. x 150 mm Lichrospher diol (5 mum) analytical column. The samples were loaded with a flow rate of 40 mul min(-1) and glyoxal-deoxyguanosine was desorbed from the trap column and eluted with an isocratic mobile phase consisting of water-acetonitrile-formic acid (50 : 50 : 0.2, v/v) at a flow rate of 5 mul min(-1). Mass spectrometric determination of glyoxal-deoxyguanosine was obtained by multiple reaction monitoring of the transition [M + H](+)m/z 326 --> m/z 210. The method was evaluated over the concentration range 0.25-50 ng ml(-1) of glyoxal-deoxyguanosine in the hydrolysate of 5 mug DNA. The method was linear with a correlation coefficient of 0.9998 in this range. The within-day (n = 6) and between-day (n = 6) precisions were determined as 1.2-11% and 1.4-11% RSD, respectively, and the recovery was close to 100%. The mass limit of detection was 15 pg, corresponding to a concentration limit of detection of 75 fg mul(-1) DNA hydrolysate solution, corresponding to 48 adducts per 10(6) normal nucleosides. The method was applied for the determination of glyoxal-deoxyguanosine in DNA hydrolysate solutions of calf thymus DNA and cell cultures after reaction or incubation with glyoxal.  相似文献   
10.
The concept of a confined thin film to enhance the desorption process is based on a reduced mass diffusion resistance. A wide thin film is formed into a microchannel by using a porous membrane as one wall of the channel enabling vapor extraction along the flow. Heat added to the channel results in vapor generation and subsequent extraction through the membrane. This experimental study investigates the performance of vapor extraction as a function of confined thin film thickness, pressure difference across the membrane and inlet concentration to the microchannel. In addition, heat added to the system was varied and results are presented in terms of the wall superheat temperature relative to the inlet saturated conditions of the binary fluid. The test section was equipped with a transparent window to observe bubble formation and vapor extraction. Results show that the performance, measured by the vapor release rate, increases for reduced channel thickness, for increased pressure difference across the membrane, and for lower inlet concentration. Results show that lower wall superheat correspond to higher heat transfer coefficients. Trends of Nusselt number and Sherwood number versus both channel Reynolds number and the product of the Reynolds number and Schmidt number are presented. Bubble formation in the channel does not degrade overall performance provided a critical heat flux condition does not occur.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号