首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   21篇
  免费   0篇
化学   5篇
物理学   16篇
  2013年   2篇
  2008年   1篇
  2006年   1篇
  2000年   1篇
  1999年   1篇
  1995年   2篇
  1994年   2篇
  1993年   2篇
  1992年   4篇
  1990年   2篇
  1987年   2篇
  1917年   1篇
排序方式: 共有21条查询结果,搜索用时 0 毫秒
1.
2.
A suite of keV polyatomic or 'cluster' projectiles was used to bombard unoxidized and oxidized self-assembled monolayer surfaces. Negative secondary ion yields, collected at the limit of single ion impacts, were measured and compared for both molecular and fragment ions. In contrast to targets that are orders of magnitude thicker than the penetration range of the primary ions, secondary ion yields from polyatomic projectile impacts on self-assembled monolayers show little to no enhancement when compared with monatomic projectiles at the same velocity. This unusual trend is most likely due to the structural arrangement and bonding characteristics of the monolayer molecules with the Au(111). Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
3.
In this study, a new solid-phase microextraction (SPME) method for simultaneous extraction of pharmaceutical compounds with acidic and basic characteristics (ibuprofen, fenoprofen, diclofenac, diazepam and loratadine) from residual water samples is proposed. In this procedure, the extraction is processed using two distinct sample pH values. The extraction is begun at pH 2.5 to promote the sorption of acidic pharmaceuticals and after 35 min the sample pH is changed to 7.0 by adding 0.4 mol L−1 disodium hydrogenphosphate, so that the basic compounds can be sorbed by the fiber (20 min). The pH change is performed without interruption of the extraction process. A comparison between the proposed method and the SPME method applied to each group of the target compounds was performed. Gas chromatography coupled to mass spectrometry was used for separation and detection of analytes. The extraction conditions for the three methods were optimized using full factorial experimental design, response surface through a Doehlert matrix and central composite design. Limits of detection (0.02-0.43 μg L−1) and correlation coefficients (0.9970-0.9998) were determined for the three methods. The proposed extraction procedure was applied to samples of sewage treatment plant effluent and untreated wastewater. Recovery and relative standard deviation values ranged from 67 to 116% and 4.6 to 14.5%, respectively, for all compounds studied. Modification of sample pH during the extraction procedure was shown to be an excellent option for all of the compounds and may be extended to the simultaneous extraction of other compounds with different acid-base characteristics.  相似文献   
4.
5.
6.
7.
8.
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号