首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   38篇
  免费   0篇
化学   7篇
力学   2篇
数学   1篇
物理学   28篇
  2014年   1篇
  2012年   1篇
  2010年   1篇
  2009年   1篇
  2008年   1篇
  2007年   1篇
  2006年   1篇
  1999年   5篇
  1997年   1篇
  1996年   1篇
  1995年   2篇
  1994年   3篇
  1993年   5篇
  1992年   2篇
  1991年   1篇
  1990年   2篇
  1988年   2篇
  1987年   1篇
  1986年   2篇
  1984年   2篇
  1968年   1篇
  1964年   1篇
排序方式: 共有38条查询结果,搜索用时 15 毫秒
1.
2.
3.
Two types of directional couplers for transverse electric (TE) modes are described: short and multihole couplers, respectively. They selectively pick one mode out of a mode mixture in an overmoded circular waveguide system. Unwanted modes are either statistically kept at low level or are suppressed by destructive interference in the coupling waveguide. Mode selectivity and directivity in multihole couplers oscillate up and down with an increasing number of holes, finally reaching a minimum of approximately 20 dB, unless there are competing modes with rational fractions of the beat wavelength. A multihole coupler for the TE02 mode (28 GHz, 63.4 mm waveguide diameter, 41 holes) and a length of 1.6 m shows a calculated directivity of 68 dB and suppresses the unwanted modes TE01 with 34 dB (24 dB), TE22 with 37 dB (45 dB), and further modes TEm (<5, m<6) with 17 dB to 34 dB in forward direction (figures in parentheses are for unwanted modes propagating in backward direction).A short directional coupler for the TE01 mode (28 GHz, 63.4 mm waveguide diameter) with 16 holes and a length of 230 mm shows a directivity of 55 to 100 dB between 27.9 and 28.1 GHz, suppressing the TE02 mode with 35 to 80 dB, the TE03 mode with 30 to 65 dB, and the TE22 mode with 30 to 70 dB.  相似文献   
4.
The biochemical conversion of cellulosic biomass to liquid transportation fuels includes the breakdown of biomass into its soluble, fermentable components. Pretreatment, the initial step in the conversion process, results in heterogeneous slurry comprised of both soluble and insoluble biomass components. For the purpose of tracking the progress of the conversion process, it is important to be able to accurately measure the fraction of insoluble biomass solids in the slurry. The current standard method involves separating the solids from the free liquor and then repeatedly washing the solids to remove the soluble fraction, a laborious and tedious process susceptible to operator variations. In this paper, we propose an alternative method for calculating the fraction of insoluble solids which does not require a washing step. The proposed method involves measuring the dry matter content of the whole slurry as well as the dry matter content in the isolated liquor fraction. We compared the two methods using three different pretreated biomass slurry samples and two oven-drying techniques for determining dry matter content, an important measurement for both methods. We also evaluated a large set of fraction insoluble solids data collected from previously analyzed pretreated samples. The proposed new method provided statistically equivalent results to the standard washing method when an infrared balance was used for determining dry matter content in the controlled measurement experiment. Similarly, in the large historical data set, there was no statistical difference shown between the wash and no-wash methods. The new method is offered as an alternative method for determining the fraction of insoluble solids.  相似文献   
5.
6.
The performance of multihole directional couplers can be considerably improved by placing a second hole structure to the existing one. The improvement may be aimed at directivity or at suppression of certain unwanted modes propagating either in forward or backward direction.  相似文献   
7.
Fast atom bombardment, combined with high-energy collision-induced tandem mass spectrometry, has been used to investigate gas-phase metal-ion interactions with captopril, enalaprilat and lisinopril, all angiotensin-converting enzyme inhibitors.Suggestions for the location of metal-binding sites are presented. For captopril, metal binding occurs most likely at both the sulphur and the nitrogen atom. For enalaprilat and lisinopril, binding preferably occurs at the amine nitrogen. Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
8.
Extended Abstract: Glass forming organic liquids and polymers exhibit long range density fluctuations with correlation length ξ in the range of 10–300 nm at temperatures above Tg (1 - 6). This follows from dynamic and static light scattering experiments revealing some unexpected features, which cannot be explained on the basis of conventional liquid state theories: (i) In static light scattering the intensity I(q → 0) is no longer proportional to the isothermal compressibility, (ii) This excess scattering Iexc shows a strong q-dependence (q = (4π/Λ.)sin(θ/2)) corresponding to a correlation length ξ in the above mentioned range, (iii) The Landau-Placzek ratio IRayleigh/2IBrillouin is much too high compared with the results of light scattering theories, (iv) In photon correlation spectroscopy a new ultraslow hydrodynamic mode (Γ ˜ q2) is detected with relaxation rates Γ about 10−6 to 10−9 lower than those of the α-process at a given temperature. In order to explain these observations, a two-state fluid model is proposed, which starts from the coexistence of “liquid-like” and “aperiodic solid-like” regions within the liquids. Such ideas have been discussed many times before, so for example A.R. Ubbelohde (7) speculates about “anticrystalline” clusters in liquids. Molecular dynamics simulations of atomic liquids showed that long range orientational fluctuations appear upon supercooling (8). A preferred icosahedral ordering is observed (9) and the number of icosahedral clusters increases with decreasing temperature (10). In connection with the interpretation of the dynamics of supercooled liquids different “two-state” models have been proposed (11 - 15). For the explanation of the light scattering results we propose that the molecules in the different dynamic states (“liquid” or “solid”) aggregate during annealing of the liquid at temperatures above Tg. Experiments showed that the equilibration times can be rather long (3 - 5), but nevertheless the liquids exhibiting long range density fluctuations are in the state of lowest free energy. We claim that our observations are the first experimental proof of the existence of such different dynamic states, which have been discussed many times before. The extended secondary clusters can also be detected by ultra small angle X-ray scattering.  相似文献   
9.
Herpes simplex virus (HSV) is one of the most prevalent viruses, with acute and recurrent infections in humans. The current gold standard for the diagnosis of HSV is viral culture which takes 2-14 days and has low sensitivity. In contrast, DNA amplification by polymerase chain reaction (PCR) can be performed within 1-2 h. We here describe a multiparameter PCR assay to simultaneously detect HSV-1 and HSV-2 DNA templates, together with integrated positive and negative controls, with product detection by melting curve analysis (MCA), in an array of semi-solid polyacrylamide gel posts. Each gel post is 0.67 μL in volume, and polymerized with all the components required for PCR. Both PCR and MCA can currently be performed in one hour and 20 min. Unprocessed genital swabs collected in universal transport medium were directly added to the reagents before or after polymerization, diffusing from atop the gel posts. The gel post platform detects HSV templates in as little as 2.5 nL of raw sample. In this study, 45 genital swab specimens were tested blindly as a preliminary validation of this platform. The concordance of PCR on gel posts with conventional PCR was 91%. The primer sequestration method introduced here (wherein different primers are placed in different sets of posts) enables the simultaneous detection of multiple pathogens for the same sample, together with positive and negative controls, on a single chip. This platform accepts unprocessed samples and is readily adaptable to detection of multiple different pathogens or biomarkers for point-of-care diagnostics.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号