首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
化学   6篇
物理学   1篇
  2014年   1篇
  2008年   1篇
  2007年   3篇
  2006年   2篇
排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
A simple, rapid, and sensitive high-performance liquid chromatographic method for estimation of efavirenz in human plasma has been developed and validated. Chromatography was performed with C18 analytical column and 50:50 acetonitrile–phosphate buffer (pH 3.5) as mobile phase. Compounds were monitored by UV detection at 247 nm. The retention time for efavirenz was 6.45 min and that for the internal standard, nelfinavir, was 2.042 min. Response was a linear over the concentration range of 0.1 μg–10 μg mL−1 in human plasma. The method was simple, specific, precise and accurate and was useful for bioequivalence and pharmacokinetic studies of efavirenz.  相似文献   
2.
A rapid and sensitive RP-HPLC method with UV detection for routine control of pramipexole in tablets was developed. Chromatography was performed with mobile phase containing a mixture of acetonitrile/phosphate buffer (60/40; v/v) with a flow rate of 0.8 mL min−1. Quantitation was accomplished with the internal standard method; the procedure was validated by linearity (correlation coefficient = 0.99892), accuracy, robustness and intermediate precision. Limit of quantitation and limit of detection were found to be 4.5 μg and 1.4 μg respectively, which indicates the method is highly sensitive. Experimental design was used during validation to calculate method robustness and intermediate precision, for robustness test three factors were considered; percentage v/v of acetonitrile, flow rate and pH; an increase in the flow rate results in a decrease of concentration found of the drug, while the percentage of organic modifier and temperature have no important effect on the response. For intermediate precision measure the considered variables were: analyst, equipment, days and obtained RSD value (0.56%, n=24) which indicated a good precision of the analytical method. The method was found to be applicable for determination of the drug in tablet formulations and the results of the developed method were compared with those of the UV spectrophotometric method to access the active pramipexole content. Revised: 13 March and 25 April 2006  相似文献   
3.
G. Srinubabu  P. Kiran Kumar 《Talanta》2007,71(3):1424-1429
A rapid and sensitive RP-HPLC method with UV detection (260 nm) for routine analysis of voriconazole in a pharmaceutical formulation (Vfend®) was developed. Chromatography was performed with mobile phase containing a mixture of acetonitrile and water (50:50, v/v) with flow rate was of 1.0 ml min−1. Quantitation was accomplished with internal standard method. The procedure was validated for linearity (correlation coefficient = 0.9999), accuracy, robustness and intermediate precision. Experimental design was used for validation of robustness and intermediate precision. To test robustness, three factors were considered. Percentage of acetonitrile in mobile phase, flow rate and pH; an increase in the flow rate results in a decrease of the drug found concentration, while the percentage of organic modifier and pH have no important effect on the response. For intermediate precision measure the variables considered were: analyst, equipment and number of days. The R.S.D. value (0.45%, n = 24) indicated a good precision of the analytical method. The proposed method was simple, highly sensitive, precise and accurate and retention time less than 4 min indicating that the method is useful for routine quality control.  相似文献   
4.
The greatest challenge for proteomics is the inherently complex nature of cellular proteomes as they are highly dynamic entities. High performance liquid chromatography is an indispensable tool in proteomics research, providing high-speed, high sensitivity separation and good resolution of proteins and peptides. Chromatographic sciences have played an animated, bustling and critical role in many fields, the next challenging analytical project for the chromatographic scientists is in the area of proteomics. Which type of analysis best determines the optimal separation technique for any proteomic study? The aim of this review is to outline the different chromatographic strategies that have been employed for analysis of complex mixtures of proteins/peptides, highlighting the role of liquid chromatography coupled to mass spectrometry.  相似文献   
5.
A rapid tandem mass spectrometric (MS-MS) method for the quantification of Oxcarbazepine (OXB) in human plasma using imipramine as an internal standard (IS) has been developed and validated. Chromatographic separation was achieved isocratically on a C18 reversed-phase column within 3.0 min, using a mobile phase of acetonitrile-10 mM ammonium formate (90 : 10 v/v) at a flow rate of 0.3 ml/min. Quantitation was achieved using multiple reaction monitoring (MRM) scan at MRM transitions m/z 253>208 and m/z 281>86 for OXB and the IS respectively. Calibration curves were linear over the concentration range of 0.2-16 mug/ml (r>0.999) with a limit of quantification of 0.2 mug/ml. Analytical recoveries of OXB from spiked human plasma were in the range of 74.9 to 76.3%. Plackett-Burman design was applied for screening of chromatographic and mass spectrometric factors; factorial design was applied for optimization of essential factors for the robustness study. A linear model was postulated and a 2(3) full factorial design was employed to estimate the model coefficients for intermediate precision. More specifically, experimental design helps the researcher to verify if changes in factor values produce a statistically significant variation of the observed response. The strategy is most effective if statistical design is used in most or all stages of the screening and optimizing process for future method validation of pharmacokinetic and bioequivalence studies.  相似文献   
6.
Granular type polyaniline (PANi), PANi nanofibers (NFs), and PANi nanotubes (NTs) expedient as working electrode materials for supercapacitors are synthesized. The synthesis procedure used in this work facilitates not only the synthesis of solid powders of the PANi nanostructures, but also thin films constituted by the same PANi nanostructures in the same experiment. PANi NFs are found to exhibit faster electrode kinetics and better capacitance when compared to PANi NTs and granular PANi. Specific capacitance and energy storage per unit mass of PANi NFs are 239.47 Fg?1 (at 0.5 Ag?1) and 43.2 Wh?kg?1, respectively. Electrical conductivity of PANi NFs is also better when compared to the other two nanostructures. Properties of the three PANi nanostructures are explicated in correlation with crystallinity, intrinsic oxidation state, doping degree, BET surface area, and ordered mesoporosity pertaining to the nanostructures.  相似文献   
7.
A high-performance liquid chromatographic method and a UV derivative spectrophotometric method for the determination of famciclovir, a highly active antiviral agent, in tablets were developed in the present work. The various parameters, such as linearity, precision, accuracy, specificity, robustness, limit of detection and limit of quantitation were studied according to International Conference on Harmonization guidelines. HPLC was carried out by using the reversed-phase technique on an RP-18 column with a mobile phase composed of 50 mM monobasic phosphate buffer and methanol (50 : 50; v/v), adjusted to pH 3.05 with orthophosphoric acid. The mobile phase was pumped at a flow rate of 1 ml/min and detection was made at 242 nm with UV dual absorbance detector. The first derivative UV spectrophotometric method was performed at 226.5 nm. Statistical analysis was done by Student's t-test and F-test, which showed no significant difference between the results obtained by the two methods. The proposed methods are highly sensitive, precise and accurate and therefore can be used for its Intended purpose.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号