全文获取类型
收费全文 | 90篇 |
免费 | 0篇 |
专业分类
化学 | 59篇 |
力学 | 4篇 |
数学 | 4篇 |
物理学 | 23篇 |
出版年
2023年 | 1篇 |
2019年 | 3篇 |
2016年 | 2篇 |
2013年 | 7篇 |
2012年 | 6篇 |
2011年 | 7篇 |
2010年 | 2篇 |
2009年 | 4篇 |
2008年 | 2篇 |
2007年 | 8篇 |
2006年 | 2篇 |
2005年 | 4篇 |
2004年 | 7篇 |
2003年 | 2篇 |
2002年 | 3篇 |
2001年 | 3篇 |
2000年 | 1篇 |
1999年 | 3篇 |
1998年 | 2篇 |
1997年 | 1篇 |
1996年 | 1篇 |
1995年 | 1篇 |
1994年 | 2篇 |
1993年 | 1篇 |
1991年 | 1篇 |
1989年 | 2篇 |
1988年 | 1篇 |
1985年 | 1篇 |
1980年 | 2篇 |
1979年 | 3篇 |
1976年 | 1篇 |
1975年 | 1篇 |
1970年 | 1篇 |
1966年 | 1篇 |
1957年 | 1篇 |
排序方式: 共有90条查询结果,搜索用时 15 毫秒
1.
J Whittaker C Whitehead M Somers 《The Journal of the Operational Research Society》2007,58(7):911-921
A principled technique for monitoring the performance of a consumer credit scorecard through time is derived from Kalman filtering. Standard approaches sporadically compare certain characteristics of the new applicants with those predicted from the scorecard. The new approach systematically updates the scorecard combining new applicant information with the previous best estimate. The dynamically updated scorecard is tracked through time and compared to limits calculated by sequential simulation from the baseline scorecard. The observation equation of the Kalman filter is tailored to take the results of fitting local scorecards by logistic regression to batches of new clients that arrive in the current time interval. The states in the Kalman filter represent the true or underlying score for each attribute in the card: the parameters of the logistic regression. Their progress in time is modelled by a random walk and the filter provides the best estimate of the scores using past and present information. We illustrate the technique using a commercial mortgage portfolio and the results indicate significant emerging deficiencies in the baseline scorecard. 相似文献
2.
3.
Muranaka A Okuda M Kobayashi N Somers K Ceulemans A 《Journal of the American Chemical Society》2004,126(14):4596-4604
Oxo-titanium phthalocyanine (TiOPc) derivatives of catechin and hematoxylin (natural ortho-diol type chiral compounds) have been prepared and characterized by spectral and chromatographic techniques. It is demonstrated that the TiOPc unit is an excellent template for chiral recognition through its isolated Q-transitions. The formation of a helical dimeric complex with hematoxylin induces strong CD-activity in the Q-band region. Ab initio geometry optimizations were combined with a Kuhn-Kirkwood coupled-oscillator mechanism to obtain the absolute configuration of hematoxylin. In addition, it is shown that the described chiroptical recognition method is sensitive to slight conformational changes. 相似文献
4.
Graham A. Bowmaker Prof. Dr. Michael I. Bruce Brian W. Skelton Neil Somers Allan H. White 《无机化学与普通化学杂志》2007,633(7):1024-1030
The complexes [Cu2Br4]2?, [Cu2I4]2?, [Cu2I2Br2]2?, [Cu2I3Cl]2?, [Ag2Cl4]2? have been characterized as their isomorphous bis(triphenylphosphoranylidene)ammonium ([Ph3PNPPh3]+ = PNP+) salts by single crystal structural determinations. All anions show the centrosymmetric doubly halogen‐bridged forms [XM(μ‐X)2MX]2? with three‐coordinate metal atoms that have been observed in [M2X4]2? complexes with other large organic cations. In [Cu2I2Br2]2? the iodide ligands occupy the bridging positions and the bromide the terminal positions, while in [Cu2I3Cl]2?, obtained in an attempt to prepare [Cu2I2Cl2]2?, two of the iodide ligands occupy the bridging positions with the third iodide and the chloride ligand occupying two statistically disordered terminal positions. In [Ag2Cl4]2? the distortion from ideal trigonal coordination of the metal atom is greater than in the copper complexes, but less than in other previously reported [Ag2Cl4]2? complexes with organic cations. The ν(MX) bands have been assigned in the far‐IR spectra, and confirm previous observations regarding the unexpectedly simple IR spectra of [Cu2X4]2? complexes. 相似文献
5.
We report six-dimensional quantum dynamics calculations of the dissociative scattering of molecular hydrogen from the copper111 surface. Two potential energy surfaces are investigated and the results are compared with experiment. Our study completes the preliminary work of Somers et al. [Chem. Phys. Lett. 360, 390 (2002)] and focuses on the role of initial vibrational excitation and on isotopic effects. None of the two investigated potential energy surfaces is found satisfactory: the use of neither potential yields reaction and vibrational excitation probabilities and vibrational efficacies that are in close agreement with experiment. In addition to showing the shortcomings of existing potential energy surfaces we point out an inconsistency in the experimental fits for D2. 相似文献
6.
The gas‐phase pyrolytic and oxidative chemistry of furans has received much attention recently because of their potential as platform chemicals and biofuels. Typically these compounds exhibit very strong ring carbon to H or CH3 bonds. 2‐Methoxyfuran had been reported to be exceptionally unstable in comparison to related substituted heterocycles in pyrolytic experiments. The origins of its reactivity are shown to be due to the very weak O–CH3, which at 189.5 ± 1.9 kJ mol?1 is some 200 kJ mol?1 weaker than C–H bonds in the molecule. We show that the reported reactivity is somewhat overestimated but that does not alter the fact that 2‐methoxyfuran is exceptionally unstable. It may prove to be a useful alternative to azomethane as a thermal source of methyl radicals. 相似文献
7.
Charles E. Nwankire Gerard G. Donohoe Xin Zhang Jonathan Siegrist Martin Somers Dirk Kurzbuch Ruairi Monaghan Maria Kitsara Robert Burger Stephen Hearty Julie Murrell Christopher Martin Martha Rook Louise Barrett Stephen Daniels Colette McDonagh Richard O’Kennedy Jens Ducrée 《Analytica chimica acta》2013
In this paper we report a centrifugal microfluidic “lab-on-a-disc” system for at-line monitoring of human immunoglobulin G (hIgG) in a typical bioprocess environment. The novelty of this device is the combination of a heterogeneous sandwich immunoassay on a serial siphon-enabled microfluidic disc with automated sequential reagent delivery and surface-confined supercritical angle fluorescence (SAF)-based detection. The device, which is compact, easy-to-use and inexpensive, enables rapid detection of hIgG from a bioprocess sample. This was achieved with, an injection moulded SAF lens that was functionalized with aminopropyltriethoxysilane (APTES) using plasma enhanced chemical vapour deposition (PECVD) for the immobilization of protein A, and a hybrid integration with a microfluidic disc substrate. Advanced flow control, including the time-sequenced release of on-board liquid reagents, was implemented by serial siphoning with ancillary capillary stops. The concentration of surfactant in each assay reagent was optimized to ensure proper functioning of the siphon-based flow control. The entire automated microfluidic assay process is completed in less than 30 min. The developed prototype system was used to accurately measure industrial bioprocess samples that contained 10 mg mL−1 of hIgG. 相似文献
8.
9.
R Bonfiglio RC King TV Olah K Merkle 《Rapid communications in mass spectrometry : RCM》1999,13(12):1175-1185
A post-column infusion system was developed in order to analyze suppression of electrospray ionization (ESI) tandem mass spectrometry response in the presence of endogenous plasma interferences. By enabling direct detection of these interfering components, this experimental system was used to analyze the ability of several common extraction procedures to remove endogenous plasma components that cause changes in the ESI response of model drug substances. Methyl-t-butyl ether (MTBE) liquid-liquid, Oasis and Empore solid-phase, and acetonitrile (ACN) protein precipitation sample preparation methods were tested using the post-column infusion system. In all cases, ACN protein precipitation samples showed the greatest amount of ESI response suppression while liquid-liquid extracts demonstrated the least. In addition, the three test compounds, phenacetin, caffeine, and a representative Merck compound, demonstrated that ESI response suppression is compound dependent. Suppression was greatest with caffeine, the most polar analyte, and the smallest for the Merck compound, the least polar analyte. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
10.
Samit Mandal J Gerl H Geissel K Hauschild M Hellström Z Janas I Kojouharov Y Kopatch RC Lemmon P Mayet Z Podolyak PH Regan H Schaffner C Schlegel J Simpson HJ Wollersheim 《Pramana》2001,57(1):161-164
Feasibility of gamma-ray spectroscopy at relativistic energies with exotic heavy-ions and new generation of germanium detectors
(segmented Clover) is discussed. An experiment with such detector array and radioactive is discussed. 相似文献