排序方式: 共有3条查询结果,搜索用时 0 毫秒
1
1.
Andrew G McDonald Sinéad Boyce Gerard P Moss Henry BF Dixon Keith F Tipton 《BMC biochemistry》2007,8(1):14
Background
We describe the database ExplorEnz, which is the primary repository for EC numbers and enzyme data that are being curated on behalf of the IUBMB. The enzyme nomenclature is incorporated into many other resources, including the ExPASy-ENZYME, BRENDA and KEGG bioinformatics databases. 相似文献2.
de Oliveira FM Somera BF Corazza MZ Yabe MJ Segatelli MG Ribeiro ES Lima EC Dias SL Tarley CR 《Talanta》2011,85(5):2417-2424
The present paper describes the synthesis of a new chemically modified cellulose microfiber through oxidation with sodium periodate and functionalization with N,N′-bis (2-aminoethyl)-1,2-ethanediamine for the fast and selective preconcentration of Cd(II) ions in flow system analysis. The new sorbentsorbent was characterized by FTIR, SEM, and surface area values. The uptake behavior of Cd(II) ions onto this sorbent was evaluated from kinetic data, pseudo-first-order and pseudo-second-order models, as well as from Langmuir, Freundlich and Langmuir-Freundlich adsorption isotherms. The maximum sorption capacity of 4.59 mg g−1 was estimated by the Langmuir-Freundlich model with fast kinetics for the sorption of Cd(II) described by the pseudo-second-order kinetic model. After characterization, the sorbent was packed in a mini-column, and a fast flow injection preconcentration system for Cd(II) determination by FAAS was developed. The best Cd(II) preconcentration condition, obtained by means of factorial design and response surface methodology, was achieved at pH 9.36 and a flow rate of 10 mL min−1 followed by elution with 1.0 mol L−1 nitric acid. By using 78 s preconcentration time, fast and highly sensitive determination of Cd(II) ions could be achieved with a limit of quantification of 0.20 μg L−1, preconcentration factor of 26, consumption index of 0.5 mL, concentration efficiency of 20 min−1, and sample throughput of 39 h−1. The repeatability for 10 replicate determinations was found to be 7.8 and 2.5% for Cd(II) ion concentrations of 5.0 and 100.0 μg L−1, respectively. The new sorbent efficiency for the interference-free preconcentration of Cd(II) ions was assessed by analysis of tap, mineral and lake waters, as well as synthetic seawater and normal saline waters. Furthermore, complex samples, such as biological samples, could be analysed by the proposed method in accordance with the accuracy attested by analysis of certified reference materials, TORT-2 (lobster hepatopancreas), and DOLT-4 (dogfish liver). 相似文献
3.
M Julia BF Flaminio Alexandre S Borges Daryl V Nydam David W Horohov Rolf Hecker Mary Beth Matychak 《Journal of immune based therapies and vaccines》2007,5(1):1-17
Background
Cytosine-phosphate-guanosine oligodeoxynucleotide (CpG-ODN) has been used successfully to induce immune responses against viral and intracellular organisms in mammals. The main objective of this study was to test the effect of CpG-ODN on antigen presenting cells of young foals. 相似文献
1