首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
化学   3篇
  2011年   1篇
  2007年   2篇
排序方式: 共有3条查询结果,搜索用时 15 毫秒
1
1.
US FDA released guidelines for bioanalytical method validation in 2001 and it became the basis for guidelines such as ANVISA and EMA. Even though there is a general agreement between these guidelines in terms of evaluation of validation parameters, significant diversity exists with respect to methodology employed. Present review compares and summarizes the regulatory guidelines issued by US FDA, ANVISA and EMA for bioanalytical method validation. This review also discusses evaluation of certain validation parameters such as matrix effect, incurred sample reanalysis, various stability aspects, effect of anticoagulant counter ions, specificity in the presence of concomitant medications, and identification of pharmacokinetic repeats wherein specific guidance and general consensus amongst scientific community does not exist.  相似文献   
2.

A new, sensitive and stability indicating liquid chromatographic method has been developed for the determination of imatinib mesylate (IM). Efficient chromatographic separation was achieved using a C18 column with simple mobile phase combination delivered in an isocratic mode and quantitation was carried out using ultraviolet detection. For the first time, a novel microwave assisted degradation procedure was employed for stress testing studies. In addition, orthogonal separation technique was applied to demonstrate selectivity of the proposed method. The method has demonstrated excellent linearity over the range of 25–1,600 ng mL−1. Moreover, the method was found to be sensitive with a low limit of detection (3.35 ng mL−1) and limit of quantitation (10.16 ng mL−1). The method has shown good and consistent recoveries (99.35–100.69%) with low intra- and inter-day relative standard deviation (RSD) (<2.5%). Experimental design confirmed that peak area was unaffected by small changes in critical factors, in robustness study. The validated method was successfully applied for determination of IM in pharmaceutical formulations.

  相似文献   
3.
A new, sensitive and stability indicating liquid chromatographic method has been developed for the determination of imatinib mesylate (IM). Efficient chromatographic separation was achieved using a C18 column with simple mobile phase combination delivered in an isocratic mode and quantitation was carried out using ultraviolet detection. For the first time, a novel microwave assisted degradation procedure was employed for stress testing studies. In addition, orthogonal separation technique was applied to demonstrate selectivity of the proposed method. The method has demonstrated excellent linearity over the range of 25–1,600 ng mL?1. Moreover, the method was found to be sensitive with a low limit of detection (3.35 ng mL?1) and limit of quantitation (10.16 ng mL?1). The method has shown good and consistent recoveries (99.35–100.69%) with low intra- and inter-day relative standard deviation (RSD) (<2.5%). Experimental design confirmed that peak area was unaffected by small changes in critical factors, in robustness study. The validated method was successfully applied for determination of IM in pharmaceutical formulations.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号