排序方式: 共有22条查询结果,搜索用时 93 毫秒
1.
R. Mateva KR. Zhilkova G. Zamfirova R. Díaz‐Calleja A. Garcia‐Bernabé 《Journal of Polymer Science.Polymer Physics》2010,48(23):2518-2529
The molecular dynamics of new poly (ω‐dodecalactam‐co‐ε‐caprolactam‐co‐propylene oxide) copolymers (DL/CL/PAC) has been investigated by using dynamic mechanical thermal analysis (DMTA) and dielectric relaxation spectroscopy (DRS) measurements. The copolymers were synthesized via anionic polymerization of relevant lactams activated with carbamoyl derivatives of telechelic hydroxyl terminated polypropylene oxide with isophorone diisocyanate (PAC). The calorimetric, X‐ray diffraction, and DMTA measurements were performed to recognize the influence of the composition ratio and the type of PAC on the physical, thermal, and mechanical properties of the synthesized copolymers. The DRS was used to study the frequency dependence of the dielectric permittivity of some isotherms from ?110 to 145 °C. Copolymerization of ε‐caprolactam with about 10 wt % ω‐dodecalactam results in a copolymer that has lower water absorption, a melting point close to that of polyamide 6 and has a high enough degree of crystallinity in respect to high storage modulus. Five dielectric relaxations have been observed in the dielectric spectra, three at lower temperature and two at higher temperature. The copolymers have two glass transition temperatures for polyamide segments and polyether blocks, indicating microphase separation in the copolymers. Other studies directed toward molecular dynamics of polyamide DL/CL/PAC copolymers have not been reported. © 2010 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys, 2010 相似文献
2.
The spring-loaded inverted pendulum (SLIP) model describes well the steady-state center-of-mass motions of a diverse range
of walking and running animals and robots. Here we ask whether the SLIP model can also explain the dynamic stability of these
gaits, and we find that it cannot do so in many physically-relevant parameter ranges. We develop an actuated, lossy, clock-torqued
SLIP, or CT-SLIP, with more realistic hip-motor torque inputs, that can capture the robust stability properties observed in
most animals and some legged robots. Variations of CT-SLIP at a similar level of detail and complexity may also be appropriate
for capturing the whole-system center-of-mass dynamics of locomotion of legged animals and robots varying widely in size and
morphology. This paper contributes to a broader program to develop mathematical models, at varied levels of detail, that capture
the dynamics of integrated organismal systems exhibiting integrated whole-body motion.
相似文献
3.
4.
5.
Abstract The displacive transition in La is studied in the pressure range up to 26 GPa and under temperatures up to 630 K with angular dispersive X-ray diffraction at the ESRF and with energy dispersive X-ray diffraction in HASYLAB to elucidate further details of this transition with an extension of the transition line up to 22.5(5) GPa and 590(10) K and a determination of the order parameter down to a level of η ≈=5· 10?4. 相似文献
6.
Hindered beta-aminoarylphosphines show promise as bidentate ligands for metal centers, but their reported synthesis requires heating at high temperatures for several days. Herein are reported conditions by which the two steps composing this synthesis, Buchwald-Hartwig amination and nucleophilic phosphorylation reactions, may both be completed in less than 3 h using microwave irradiation. The effects of several parameters on the outcome of the amination reaction are discussed, as are some indications of the scope within which each of these microwave protocols is effective. 相似文献
7.
Modeling quantitative structure-activity relationships (QSAR) is considered with an emphasis on prediction. An abundance of methods are available to develop such models. Using a harmonious approach that balances the bias and variance of predictions, the best calibration models are identified relative to the bias and variance criteria used. Criteria utilized to determine the adequacy of models are the root mean square error of calibration (RMSEC) and validation (RMSEV), respective R2 values, and the norm of the regression vector. QSAR data from the literature are used to demonstrate concepts. For these data sets and criteria used, it is suggested that models obtained by ridge regression (RR) are more harmonious and parsimonious than models obtained by partial least squares (PLS) and principal component regression (PCR) when the data is mean-centered. The most harmonious RR models have the best bias/variance tradeoff, reflected by the smallest RMSEC, RMSEV, and regression vector norms and the largest calibration and validation R2 values. The most parsimonious RR models have the smallest effective rank. 相似文献
8.
9.
Often the rate of passage of gaseous molecules through model zeolites is too small to be computed directly. An estimate for the rate of passage of CCl4 through the 8-ring window in a model of zeolite A has been obtained by combining a direct evaluation of the free energy profile and an adaptation of the rare events method. First the free energy profile is found from a direct evaluation of the canonical partition function at high dilution and the transition state theory rate constant obtained. The dynamic correction factor is then estimated from molecular dynamics runs and used to compute the actual rate keff. The method is used to estimate the rate of passage through the 8-ring window in a rigid model of zeolite A, and the results are compared with those obtained from rigid models with expanded windows and from the flexible model. Even a small expansion in the 8-ring window diameter increases the rate significantly, but the changes associated with a flexible cage are small. 相似文献
10.
F Mayer B K Kr?mer K M Ress V Kühlkamp H M Liebich T Risler L Seipel 《Journal of chromatography. A》1991,572(1-2):339-345
A simplified, rapid and inexpensive extraction procedure for the determination of the antiarrhythmic drug disopyramide and its main metabolite mono-N-desalkylated disopyramide in serum by high-performance liquid chromatography has been developed. The analysis uses ultraviolet detection at 254 nm, and a 5 micron reversed-phase column with a mobile phase of water-triethylamine-acetonitrile-PIC-B8 reagent. Serum extraction is performed with dichloromethane and 1 M sodium hydroxide. p-Chlorodisopyramide is used as internal standard. Recovery rates were 94.5% (S.D. 5.7%) for disopyramide, 96.8% (S.D. 2.2%) for mono-N-desalkylated disopyramide and 97.9% (S.D. 2.8%) for the internal standard. 相似文献