首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   20篇
  免费   0篇
化学   10篇
力学   1篇
数学   2篇
物理学   7篇
  2019年   1篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2009年   3篇
  2008年   2篇
  2006年   2篇
  2005年   2篇
  2002年   1篇
  1997年   1篇
  1995年   2篇
  1992年   3篇
排序方式: 共有20条查询结果,搜索用时 15 毫秒
1.
Attempts to theoretically address the problems involved in transferring linear gradient elution methods have been somewhat ad hoc due to the simplifying assumptions usually made in conventional gradient elution theory. Until now, all equations based on the k* parameter of linear gradient elution theory used as the basis for predicting the separation selectivity have not explicitly included the effect of the dwell volume (VD). Using an exact equation for predicting k*, that is, one which fully accounts in an a priori fashion for VD, we find a set of simple yet exact equations which unequivocally must be satisfied to transfer an optimized linear gradient elution method from one system (column or instrument or both) to another. These relationships absolutely mandate that a change in the instrument dwell volume requires a proportional change in the column volume; in turn, a change in the column volume requires a proportional change in the flow rate and/or gradient time to maintain a constant gradient steepness. Although we are not the first to suggest these guidelines, this work provides a complete theoretical foundation for these exact guidelines for the maintenance of gradient selectivity for the case of transferring a linear gradient elution method between different columns packed with the same particles and/or between different instruments.  相似文献   
2.
3.
Chromatographers are cautioned to avoid gradient elution when isocratic elution will do. In this work, we compared the analytical properties of gradient and isocratic separations of a sample which can be done quite readily under isocratic conditions. We found that gradient elution gave a shorter overall analysis with similar resolution of the critical pair compared to isocratic elution without sacrificing repeatability in retention time, peak area and peak height or linearity of the calibration curve. We also obtained acceptable repeatability in peak area/height and linearity of calibrations curves for a sample that required gradient elution using a practical baseline subtraction technique. Based on these results and related work which show that columns can be reequilibrated by flushing with less than two column volumes of the initial eluent, we conclude that many of the reasons given to avoid gradient elution deserve serious reconsideration, especially for those samples which are easily separated isocratically. However, we believe isocratic elution will remain preferable when: (1) the sample contains less than 10 weakly retained components (i.e. the last peak elutes with k' < 5) or (2) the gradient baseline impedes trace analysis.  相似文献   
4.
Multivalent single chain variable fragments (scFv) show increased affinity to tumor-associated antigens compared to monovalent scFv and intact monoclonal antibodies (mAb). Multivalent constructs can be derived from self-associating or covalent scFv with covalent constructs offering improved in vivo and in vitro stability. Covalent attachment of scFv can be achieved using genetically engineered expression vectors that afford scFv with site specific cysteine functionality. Expression vectors for di-scFv-C wherein the cysteine is located in the center of two scFv have also been developed for attaching chemically reactive linkers. In the example illustrated here, the di-scFv-C is derived from a mAb directed against the MUC1 epitope, which is presented on cancer cells. To achieve multivalency, a chemical crosslinking strategy utilizing various azide and multi-alkyne functionalized polyethylene glycol (PEG) linkers was implemented. Conjugation was achieved by attachment of these linkers to the scFv thiol functionality. Chemoselective ligation was employed to covalently link different protein conjugates via copper(I) catalyzed azide alkyne 1,3-dipolar cycloaddition reaction (CuAAC) chemistry. Ligations were achieved in >70% yield using a specific set of linkers as determined by SDS-PAGE and densitometry. ELISA showed increased tumor binding of a tetravalent scFv providing a versatile chemical crosslinking strategy for construction of multivalent and bi-specific immunoconjugates that retain biological activity and have potential application in pre-targeted radioimmunotherapy and imaging.  相似文献   
5.
6.
7.
A fully synthetic trivalent mimotope of gp120 conjugated to pan allelic HLA DR binding epitope was prepared using solid-phase peptide synthesis and optimized copper-catalyzed azide-alkyne cycloaddition. The methodology efficiently provides chemically uniform heteromultimeric peptide constructs with enhanced binding, avidity, and specificity toward an established HIV-neutralizing human antibody, MAb b12. The versatile synthetic strategy serves as a powerful platform for the development of synthetic peptides as potential HIV-1 vaccine candidates.  相似文献   
8.
We studied the run-to-run repeatability of the retention times of both non-ionizable and basic compounds chromatographed using buffered eluents. The effect of flow rate, organic modifier and other additives, buffer type/concentration, stationary phase type, batch-to-batch preparation of the initial eluent, gradient time, sample type and intra-day changes on retention repeatability were examined. We also assessed the effect of column storage solvent conditions on the inter-day repeatability. Although retention repeatability is strongly influenced by many parameters (flow rate, solvent compressibility compensation, precision of temperature control, and buffer/stationary phase type), our primary finding is that with a reasonable size column (15cmx4.6mm (i.d.)) two column volumes of re-equilibration with initial eluent suffices to provide acceptable repeatability (no worse than 0.004min) for both non-ionizable and basic analytes under a wide variety of conditions. Under ideal conditions (e.g. the right buffer, flow rate, etc.) it is possible to obtain truly extraordinary repeatability often as good as 0.0004min. These absolute fluctuations in retention translate to worst case changes in resolution of 0.2 units and average changes of only 0.02 units.  相似文献   
9.
In this work we determined when the state of thermodynamic (full) equilibrium, i.e. time-invariate solute retention, was achieved in gradient elution reversed-phase chromatography. We investigated the effects of flow rate, temperature, organic modifier, buffer type/concentration, stationary phase type, n-butanol as eluent additive, and pore size. We also measured how selectivity varied with reequilibration time. Stationary phase wetting and the ability of the stationary phase to resist changes in pH strongly affect the time needed to reach full equilibrium. For example, full equilibrium is realized with many endcapped stationary phases after flushing with only two column volumes of acetonitrile-water containing 1% (v/v) n-butanol and 0.1% (v/v) trifluoroacetic acid. Trends in retention time (<0.010min) and selectivity become quite small after only five column volumes of reequilibration. We give practical guidelines that provide fast full equilibrium for basic compounds when chromatographed in buffered eluents.  相似文献   
10.
In this paper we introduce a two-sided Arnoldi method for the reduction of high order linear systems and we propose useful extensions, first of all a stopping criterion to find a suitable order for the reduced model and secondly, a selection procedure to significantly improve the performance in the multi-input multi-output (MIMO) case. One application is in micro-electro-mechanical systems (MEMS). We consider a thermo-electric micro thruster model, and a comparison between the commonly used Arnoldi algorithm and the two-sided Arnoldi is performed.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号