Ozkan  Cansel Kose  Kurbanoglu  Sevinc  Esim  Ozgur  Savaser  Ayhan  Ozkan  Sibel A.  Ozkan  Yalcin 《Chromatographia》2016,79(17):1143-1151

In the proposed work, the simultaneous analysis of amlodipine–rosuvastatin and amlodipine–atorvastatin in their dosage forms was achieved. Simultaneous dissolution profiles of the amlodipine–rosuvastatin and amlodipine–atorvastatin tablets are realized using Apparatus II with a simple, accurate and precise RP-LC method. The mobile phase consisting of 0.2 % H3PO4 and pH 5:methanol:acetonitrile (46:27:27) was used. The samples of 10 µL were injected onto a Zorbax SB C18 (100 mm, 4.6 mm, 3.5 µm particle size) column with 1.2 µL min−1 flow rate. The samples were detected at 236 nm. By plotting peak area ratios vs. concentration, the linearity for amlodipine–rosuvastatin and amlodipine–atorvastatin was determined. With the developed RP-LC method, AML, ROS and ATOR were detected within the range of 0.25–10, 0.5–10 and 0.25–25 µg mL−1, respectively. LOD and LOQ values were also calculated as 0.028, 0.058, 0.021 and 0.095 µg mL−1, 0.195 µg mL−1, 0.070 µg mL−1 for AML, ROS and ATOR, respectively. System suitability tests parameters, such as capacity factor, selectivity to previous peak, selectivity to next peak, resolution to previous peak, resolution to next peak, tailing factor, theoretical number of plates, were performed and found coherent with the ICH guideline parameters. The proposed method has been extensively validated in terms of recovery, and recovery results were between 99 and 101 %. For proving the precision, between-day and within-day repeatability results of the method were proposed. The method can be used for the simultaneous determination of amlodipine–rosuvastatin and amlodipine–atorvastatin.

  相似文献   
2.
To support real biological sample application, a simple, selective and rapid LC–MS method has been developed and validated for the sensitive determination of metoclopramide in rabbit blood, ex vivo permeation studies and pharmaceutical dosage form. LC–MS analysis was performed isocratically on a Zorbax SB-C18 column with a mobile phase consisting of methanol:ammonium acetate buffer (pH 3.0) 75:25 (v/v) at a flow rate of 0.70 mL min?1. The outlet of the column was connected to a single quadrupole mass spectrometer with positive mass spectrometric detection. Ions were detected in the positive multiple reaction monitoring mode. The assay was linear over the concentration range of 1.25–200 pg μL?1 with a limit of detection of 0.077 pg μL?1 for standard solutions and 2.5–200 pg μL?1 with a limit of detection of 0.42 pg μL?1 for serum samples. The method is applicable, covering a variety of pharmaceutical and biological studies. Metoclopramide was extracted from rabbit blood by liquid–liquid extraction using ether as the extraction solvent. The reproducibility of the method was found to be between 0.96 and 1.98 % (RSD) values. The proposed method has been extensively validated for the determination of metoclopramide in all working media. The sample preparations, flow rate and run time of the analytical systems are not time consuming. Moreover, for the stability of metoclopramide, the effect of temperature, UV light, H2O2, HCl and NaOH were also investigated.  相似文献   
3.
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号