首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   31篇
  免费   0篇
化学   29篇
物理学   2篇
  2012年   2篇
  2011年   2篇
  2010年   1篇
  2009年   2篇
  2007年   5篇
  2006年   1篇
  2005年   3篇
  2004年   5篇
  2003年   2篇
  2002年   2篇
  2001年   1篇
  2000年   1篇
  1999年   1篇
  1993年   1篇
  1989年   1篇
  1985年   1篇
排序方式: 共有31条查询结果,搜索用时 31 毫秒
1.
Controlled in-source ion-molecule reactions are performed for the first time in an external matrix assisted laser desorption ionization (MALDI) source of a Fourier transform ion cyclotron resonance mass spectrometer. The MALDI source with a hexapole ion guide that was originally designed to incorporate pulsed gas to collisionally cool ions (Baykut, G.; Jertz, R.; Witt, M. Rapid Commun. Mass Spectrom. 2000, 14, 1238-1247) has been modified to allow the study of in-source ion-molecule reactions. Upon laser desorption, a reaction gas was introduced through a second inlet and allowed to interact with the MALDI-generated ions trapped in the hexapole ion guide. Performing ion-molecule reactions in the high pressure range of the ion source prior to analysis in the ion cyclotron resonance (ICR) cell allows to maintain the ultra high vacuum in the cell which is crucial for high mass resolution measurements. In addition, due to the reaction gas pressure in the hexapole product ion formation is much faster than would be otherwise possible in the ICR cell. H/D exchange reactions with different peptides are investigated, as are proton-bound complex formations. A typical experimental sequence would be ion accumulation in the hexapole ion guide from multiple laser shots, addition of cooling gas during ion formation, addition of reaction gas, varied time delays for the ion-molecule reactions, and transmission of the product ions into the ICR cell for mass analysis. In this MALDI source H/D exchange reactions for different protonated peptides are investigated, as well as proton-bound complex formations with the reaction gas triethylamine. Amino acid sequence, structural flexibility and folding state of the peptides can be seen to play a part in the reactivity of such ions.  相似文献   
2.
A CZE method was developed and validated for the analysis of Olmesartan medoxomil (OLMD) in tablets. The influences of pH, buffer concentration, applied voltage and capillary temperature on the migration time of OLMD were investigated. About 50 mM pH 6.5 phosphate buffer were used as background electrolyte. The optimum instrument parameters were found to be 30 °C temperature with 30 kV applied voltage and diode array detection was carried out at 210 nm. OLMD was hydrodynamically injected (P inj  = 50 mbar, t inj  = 3 s) and an internal standard, diflunisal (IS), was used to improve the precision and repeatability. Under these conditions, the migration time of OLMD was 2.32 min and the total analysis time was shorter than 5 min. Linearity range for the developed method was found to be 2.0–50.0 μg mL?1 and the limit of detection was 0.5 μg mL?1. The developed method was applied for the analysis of OLMD in pharmaceutical tablet formulations.  相似文献   
3.
Many polymeric membranes are produced by phase inversion technique invented by Loeb and Sourirajan in 1962. The dry-casting method is one of the major phase inversion techniques in which a homogeneous polymer solution consisting of solvent(s) and nonsolvent(s) is cast on a support and then evaporation of the casting solution takes place under convective conditions. In this paper, we model membrane formation by the dry-casting method. The model takes into account film shrinkage, evaporative cooling, coupled heat, and mass transfer and incorporates practical and reliable diffusion theory as well as complex boundary conditions especially at the polymer solution/air interface. The predictions from the model provide composition paths, temperature, and thickness of the solution. By plotting the composition paths on the ternary phase diagram, we ascertain the general structural characteristics of the membranes prepared from particular casting conditions. The predictive ability of the model was evaluated by comparing the results with the experimental data obtained from gravimetric measurements for cellulose acetate (CA)–acetone–water system. In an attempt to illustrate the importance of diffusion formalism on the predictions, recently proposed multicomponent diffusion theory and its simplified forms were utilized in the model. The computational results show that the critical factor for capturing the accurate behavior of membrane formation is the diffusion formalism utilized in the model.  相似文献   
4.
Collision-induced dissociation and infrared multiphoton dissociation of ions formed in di- and tri-ethylamine, di- and tri-n-propylamine, and di-isopropylamine were investigated by Fourier-transform ion-cyclotron resonance mass spectrometry. Molecular ions of all amines except di-n-propylamine produced similar fragment ions when subjected to either dissociation technique. The initial fragmentation involved CαCβ bond cleavage, loss of an alkyl radical, and formation of an immonium ions. Subsequent fragmentations of the immonium ions produced by both dissociation mechanisms involved McLafferty-type rearrangements and loss of alkenes. The molecular ion of di-n-propylamine fragmented by a different mechanism when subjected to infrared irradiation. Protonated molecules of di- and tri-n-propylamine yielded C3H6 and an ammonium ion upon infrared multiphoton dissociation, while protonated molecules of the other amines did not dissociate when this technique was applied. In contrast, collision-induced dissociation produced fragmentation for all protonated molecules. Explanation of the different fragmentations observed for the two dissociation techniques is given in terms of a mechanism involving a tight transition state for protonated di- and tri-n-propylamine dissociation.  相似文献   
5.
Electron capture dissociation (ECD) of polypeptide cations was obtained with pencil and hollow electron beams for both sidekick and gas-assisted dynamic ion trapping (GADT) using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with an electrostatic ion transfer line. Increasing the number of trapped ions by multiple ICR trap loads using GADT improved the ECD sensitivity in comparison with sidekick ion trapping and ECD efficiency in comparison with single ion trap load by GADT. Furthermore, enhanced sensitivity made it possible to observe ECD in a wide range of electron energies (0-50 eV). The degree, rate and fragmentation characteristics of ECD FTICR-MS were investigated as functions of electron energy, electron irradiation time, electron flux and ion trapping parameters for this broad energy range. The results obtained show that the rate of ECD is higher for more energetic (>1 eV) electrons. Long electron irradiation time with energetic electrons reduces average fragment ion mass and decreases efficiency of formation of c- and z-type ions. The obtained dependencies suggest that the average fragment ion mass and the ECD efficiency are functions of the total fluence of the electron beam (electron energy multiplied by irradiation time). The measured electron energy distributions in low-energy ECD and hot ECD regimes are about 1 eV at full width half maximum in employed experimental configurations.  相似文献   
6.
7.
Apak R  Baykut F  Aydin A 《Talanta》1989,36(10):993-998
Of the chloro-substituted benzoic acids, the 2-chloro and 2,4-dichloro compounds yield higher effective molar absorptivities than benzoic acid does in the Rhodamine B-benzene extractive spectrophotometric procedure for determination of uranium(VI). Carbonyl compounds (especially acetone) in the organic phase enhance the extraction of the ion associate. The stoichiometry of the complexes has been determined, and a method of computing the extraction constants of the ion-associates developed. A spectrophotometric method for determining uranium in the presence of interfering ions has been designed.  相似文献   
8.
Vapor–liquid equilibrium (VLE) data for binary toluene/PVAC, methanol/PVAC and ternary toluene/methanol/PVAC systems have been measured at 100 °C by using vapor-phase infrared spectroscopy. Binary data have been compared with literature data measured by different experimental techniques and agreement between our measurements and others was found to be good. The ternary VLE data indicate that the solubility of methanol in PVAC is not influenced by the presence of toluene, while the solubility of toluene is lowered due to presence of methanol. To predict ternary VLE data, the Entropic free volume and Kannan free volume models and the Flory-Huggins theory were used. The predictive abilities of Flory-Huggins theory and the Kannan free volume model are similar and better than that of the Entropic free volume model.  相似文献   
9.
A dynamic method is applied to measure the mobility of gas-phase ions in the dual ion funnel interface of the electrospray source of a quadrupole orthogonal time-of-flight mass spectrometer. In a new operational mode, a potential barrier was formed in the second ion funnel of the mass spectrometer and then progressively increased. In this region, a flow of gas drags the ions into the mass spectrometer while the electric force applied by the potential barrier decelerates them. Ions with lower mobility can be carried by the gas flow more easily than those with high mobility. Thus, electrical forces can block the more mobile ions more easily. Hence, the electric barrier formed in the ion funnel permits only ions below a certain mobility threshold to enter the mass spectrometer. When the barrier voltage is increased, this threshold moves from high to low mobilities. Ions with mobilities above the threshold cannot enter the mass spectrometer, and their signal decreases to zero. Thus, in a barrier voltage scan, mass spectrometric signals of ions sequentially disappear. Differentiation of these decreasing ion signal curves produces peaks from which an ion mobility spectrum can be reconstructed. Blocking voltages, i.e., the positions of the peaks on the barrier voltage scale are directly related to the mobility of these ions. An internal calibration using ions with known mobility values helps determine the unknown ion mobilities and allows calculation of ionic cross sections.  相似文献   
10.
Zafirlukast (ZAF) is a leukotriene receptor antagonist used in the treatment of chronic asthma. In this study, a simple and sensitive reversed-phase, high-performance liquid chromatographic method was developed for the determination of ZAF in pharmaceutical formulations and human plasma. Piribedil was used as an internal standard. Analysis was carried out on a Nucleosil C18 100 A (150 mm x 4.6 mm id, 5 Vm) column with acetonitrile-pH 3.0 acetate buffer (70 + 30, v/v) as the mobile phase at a flow rate of 0.8 mL/min. The peak was detected by an ultraviolet detector set at a wavelength of 240 nm. The retention times were about 3.9 min for piribedil and 5.8 min for ZAF. The developed method was applied to the determination of ZAF in its pharmaceutical formulation and spiked human plasma. For quantification of ZAF in spiked plasma, proteins were precipitated with ethanol before chromatographic analysis. The calibration range was linear from 49.69-437.50 ng/mL in spiked plasma. The absolute recovery from spiked plasma was 98.73 +/- 0.42% at a concentration of 254.78 ng/mL of ZAF. No endogenous substances from plasma were found to interfere.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号