首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
化学   6篇
物理学   1篇
  2021年   1篇
  2011年   2篇
  2010年   1篇
  2007年   2篇
  2006年   1篇
排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
Capillary gel electrophoresis (CGE) methods with UV detection were developed for reduced and non‐reduced mAb analysis. These methods can be used to evaluate mAb purity, offering more reproducible quantitation compared with that of traditional SDS‐PAGE methods. These CGE methods have been utilized as platform technology for bioprocess development, formulation development, mAb characterization, drug substance/drug product release testing as well as a required methodology for stability testing. We have found these CGE methods to be applicable across a platform of mAbs in preclinical and clinical development, with the majority of mAbs requiring no modification to the method conditions. This methodology has been ICH validated and transferred to several supporting organizations. The data presented herein describes the development of CGE methodology, platform application to mAb purity analysis, ICH validation, reliability metrics, and considerations on technology enhancement for improved performance and throughput.  相似文献   
2.
Interlaboratory comparisons are essential to bringing emerging technologies into biopharmaceutical industry practice and regulatory acceptance. As a result, an international team including 12 laboratories from 10 independent biopharmaceutical companies in the United States and Switzerland was formed to evaluate the precision and robustness of capillary isoelectric focusing (CIEF) to assess the charge heterogeneity of monoclonal antibodies. The different laboratories determined the apparent pI and the relative distribution of the charge isoforms of a representative monoclonal antibody (rMAb) sample using the same CIEF method. Statistical evaluation of the data was performed to determine within and between-laboratory consistencies and outlying information. The apparent pI data generated for each charge variant peak showed very good precision between laboratories with percentage of RSD values of ??0.5%. Similarly, the percentage of RSD for the rMAb charge variants percent peak area values are ??4.4% across different laboratories with different analysts using different lots of ampholytes and multiple instruments. Taken together, these results validate the appropriate use of CIEF in the biopharmaceutical industry in support of regulatory submissions.  相似文献   
3.
4.
An international project team (including members from US, Canada and UK) has been formed from a number of interested biopharmaceutical companies and regulatory authorities to conduct a cross-organisation collaboration exercise. The results from this exercise demonstrate the robustness of CE-SDS across eight different organisations that used instruments of the same equipment model, the same reagents, and the same methodology. Data generated from the analysis of a series of molecular weight markers showed very good precision with regards to relative migration time (RMT) both within and between organisations. The apparent molecular weight of bovine serum albumin (BSA) was measured with good precision to within approximately 2% RSD across the participants. A representative IgG sample showed similar results with regards to relative migration time of its 3 main components, IgG Light Chain, IgG Non-glycosylated Heavy Chain, and IgG Heavy Chain. Fractional peak area for each peak also showed good agreement, with less than 9% RSD for all peaks. This exercise will facilitate both increased regulatory and industrial opinion of CE for biopharmaceutical analysis.CE in the Biotechnology & Pharmaceutical Industries: 7th Symposium on the Practical Applications for the Analysis of Proteins, Nucleotides and Small Molecules, Montreal, Canada, August 12–16, 2005  相似文献   
5.
An international project team (including members from US, Canada and UK) was formed from a number of interested biopharmaceutical companies and regulatory authorities to conduct a cross-organisation collaboration exercise. The results of the first comparison with eight different organisations that used instruments of the same equipment model, the same reagents, and the same methodology has been reported previously [1]. This report represents the addition of other instruments using a different run buffer. The relative migration times were different, as expected, prohibiting a direct comparison between companies. The within-organisation variability was low for both relative migration time (<0.34% RSD% for all companies save one) and the peak area (<5% RSD% for all companies save one) when measuring the purity of a representative IgG sample. The apparent molecular weight of bovine serum albumin was measured with good precision (less than 10% RSD% across all companies) to the theoretical value when all data is utilized (67.5 kDa compared to 66.4 kDa). For a representative IgG sample, the three main components, IgG Light Chain, IgG Non-glycosylated Heavy Chain, and IgG Heavy Chain, could not be separated, specifically the IgG Non-glycosylated Heavy Chain and IgG Heavy Chain. When the IgG Non-glycosylated Heavy Chain and IgG Heavy Chain were combined for all organisations, the fractional peak area for the IgG Light Chain and IgG Non-glycosylated Heavy Chain + IgG Heavy Chain peak also showed excellent agreement, with less than 7.5 and 3.5% RSD%, respectively. The value of this exercise is in demonstrating the reliability of CE for the determination of apparent size of biopharmaceutical proteins. This underpins the appropriate use of such CE data in support of regulatory submissions.  相似文献   
6.
A capillary zone electrophoresis (CZE) method was developed for the rapid analysis of charge heterogeneity of immunoglobulin G (IgG) monoclonal antibodies (mAbs). The separation was carried out in a short, dynamically coated fused-silica capillary. A number of separation parameters were investigated and optimized, including pH, concentration of the separation buffer (ε-amino caproic acid), concentration of the triethylenetetramine (TETA) dynamic coating, the capillary internal diameter and the field strength used for the separation. The effects of between-run flushing of the capillary and the data acquisition rate were also evaluated. Under the optimized conditions, a fast (<5 min), selective and reproducible separation of mAb charge variants was achieved under a very high electric field strength (1000 V/cm). This method also requires only a short conditioning of the capillary, with between-run conditioning completed within 2 min. The method was evaluated for specificity, sensitivity, linearity, accuracy and precision. The same separation conditions were applied to the rapid separation (2-5 min) of charge variants of multiple monoclonal antibodies with pI in the range of 7.0-9.5. Compared with other existing methods for charge variants analysis, this method has several advantages including a short run time, rapid capillary conditioning and simple sample preparation.  相似文献   
7.

An international project team (including members from US, Canada and UK) was formed from a number of interested biopharmaceutical companies and regulatory authorities to conduct a cross-organisation collaboration exercise. The results of the first comparison with eight different organisations that used instruments of the same equipment model, the same reagents, and the same methodology has been reported previously [1]. This report represents the addition of other instruments using a different run buffer. The relative migration times were different, as expected, prohibiting a direct comparison between companies. The within-organisation variability was low for both relative migration time (<0.34% RSD% for all companies save one) and the peak area (<5% RSD% for all companies save one) when measuring the purity of a representative IgG sample. The apparent molecular weight of bovine serum albumin was measured with good precision (less than 10% RSD% across all companies) to the theoretical value when all data is utilized (67.5 kDa compared to 66.4 kDa). For a representative IgG sample, the three main components, IgG Light Chain, IgG Non-glycosylated Heavy Chain, and IgG Heavy Chain, could not be separated, specifically the IgG Non-glycosylated Heavy Chain and IgG Heavy Chain. When the IgG Non-glycosylated Heavy Chain and IgG Heavy Chain were combined for all organisations, the fractional peak area for the IgG Light Chain and IgG Non-glycosylated Heavy Chain + IgG Heavy Chain peak also showed excellent agreement, with less than 7.5 and 3.5% RSD%, respectively. The value of this exercise is in demonstrating the reliability of CE for the determination of apparent size of biopharmaceutical proteins. This underpins the appropriate use of such CE data in support of regulatory submissions.

  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号