首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   1篇
化学   14篇
力学   1篇
数学   2篇
  2023年   3篇
  2021年   3篇
  2020年   2篇
  2019年   1篇
  2015年   2篇
  2004年   1篇
  2003年   2篇
  1968年   1篇
  1942年   1篇
  1937年   1篇
排序方式: 共有17条查询结果,搜索用时 0 毫秒
1.
Environmental volatile organic compounds (VOCs) from the ambient air potentially influence on-line breath analysis measurements by secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS). The aim of this study was to investigate how inhaling through a VOC filter affects the detected breath profiles and whether it is feasible to integrate such filters into routine measurements. A total of 24 adult participants performed paired breath analysis measurements with and without the use of an activated carbon filter for inspiration. Concordance correlation coefficients (CCCs) and the Bland–Altman analysis were used to assess the agreement between the two methods. Additionally, the effect on a selection of known metabolites and contaminants was analyzed. Out of all the detected features, 78.3% showed at least a moderate agreement before and after filter usage (CCC > 0.9). The decrease in agreement of the remaining m/z features was mostly associated with reduced signal intensities after filter usage. Although a moderate-to-substantial concordance was found for almost 80% of the m/z features, the filter still had an effect by decreasing signal intensities, not only for contaminants, but also for some of the studied metabolites. Operationally, the use of the filter complicated and slowed down the conductance of measurements, limiting its applicability in clinical studies.  相似文献   
2.
Viroporins are small ion channels in membranes of enveloped viruses that play key roles during viral life cycles. To use viroporins as drug targets against viral infection requires in-depth mechanistic understanding and, with that, methods that enable investigations under in situ conditions. Here, we apply surface-enhanced infrared absorption (SEIRA) spectroscopy to Influenza A M2 reconstituted within a solid-supported membrane, to shed light on the mechanics of its viroporin function. M2 is a paradigm of pH-activated proton channels and controls the proton flux into the viral interior during viral infection. We use SEIRA to track the large-scale reorientation of M2’s transmembrane α-helices in situ during pH-activated channel opening. We quantify this event as a helical tilt from 26° to 40° by correlating the experimental results with solid-state nuclear magnetic resonance-informed computational spectroscopy. This mechanical motion is impeded upon addition of the inhibitor rimantadine, giving a direct spectroscopic marker to test antiviral activity. The presented approach provides a spectroscopic tool to quantify large-scale structural changes and to track the function and inhibition of the growing number of viroporins from pathogenic viruses in future studies.  相似文献   
3.
Strontium guanidinate, SrC(NH)3, the first compound with a doubly deprotonated guanidine unit, was synthesized from strontium and guanidine in liquid ammonia and characterized by X‐ray and neutron diffraction, IR spectroscopy, and density‐functional theory including harmonic phonon calculations. The compound crystallizes in the hexagonal space group P63/m, constitutes the nitrogen analogue of strontium carbonate, SrCO3, and its structure follows a layered motif between Sr2+ ions and complex anions of the type C(NH)32?; the anions adopt the peculiar trinacria shape. A comparison of theoretical phonons with experimental IR bands as well as quantum‐chemical bonding analyses yield a first insight into bonding and packing of the formerly unknown anion in the crystal.  相似文献   
4.
5.
We report the crystal structure of Ba(CN3H4)2 as synthesized from liquid ammonia. Structure solution based on X-ray diffraction data suffers from a severe pseudo-tetragonal problem due to extreme scattering contrast, so the true monoclinic symmetry is detectable only from neutron powder diffraction patterns, and structure solution and refinement was greatly aided by density-functional theory. The symmetry lowering is due to slight deviations of the guanidinate anion from the mirror plane in space group P b2, a necessity of hydrogen bonding. At 300 K, barium guanidinate crystallizes in P21/c with a=6.26439(2) Å, b=16.58527(5) Å, c=6.25960(2) Å, and a monoclinic angle of β=90.000(1)°. To improve the data-to-parameter ratio, anisotropic displacement parameters from first-principles theory were incorporated in the neutron refinement. Given the correct structural model, the positional parameters of the heavy atoms were also refinable from X-ray diffraction of a twinned crystal. The two independent guanidinate anions adopt the all-trans- and the anti-shape. The Ba cation is coordinated by eight imino nitrogens in a square antiprism with Ba−N contacts between 2.81 and 3.04 Å. The IR and Raman spectra of barium guanidinate were compared with DFT-calculated phonon spectra to identify the vibrational modes.  相似文献   
6.
The pH-responsive nature of two self-assembled NDI-peptide amphiphile conjugates is reported. The diethoxy substituted NDI showed a pH-dependent assembly behaviour, as expected. In contrast, the isopropylamino- and ethoxy-substituted NDI based supramolecular polymer was stable at acidic and basic aqueous conditions. This finding highlights how subtle changes in the molecular design of π-stacked chromophore-peptide conjugates have a drastic impact on their equilibrium structure and ultimately functional properties.  相似文献   
7.
The present study provides a novel, selective analysis method for the determination of low xanthate concentrations. The rising concern over the environmental effects of xanthates demands the development of analysis methods which this study answers. Complex formation in aqueous solution between xanthates and an excess of Co(II), Ni(II), Pb(II), Cd(II), Cu(II), and Zn(II) ions was utilized to selectively determine xanthates by high-performance liquid chromatography–inductively coupled plasma tandem mass spectrometry for the first time. The complexes that were formed were extracted to ethyl acetate using liquid–liquid extraction and separated by high-performance liquid chromatography technique before the quantitative determination of metal ions and sulfur in the xanthate complexes. Good separation and high measurement sensitivity were achieved using Cu(II) as the complex metal ion. The analysis method was optimized for the determination of sodium isopropyl xanthate and sodium isobutyl xanthate with detection limits of 24.7 and 13.3 μg/L, respectively. With a linear calibration range of 0.1–15 mg/L and a total analysis time of 4–5 min, the present method is a fast and sensitive option for selective xanthate determination.  相似文献   
8.
9.
The on-line coupling of capillary electrophoresis (CE) with electrospray-time-of-flight mass spectrometry (MS) has been used to obtain patterns of peptides and proteins present in the urine of healthy human individuals. This led to the establishment of a "normal urine polypeptide pattern", consisting of 247 polypeptides, each of which was found in more than 50% of healthy individuals. Applying CE-MS to the analysis of urine of patients with kidney disease revealed differences in polypeptide pattern. Twenty-seven polypeptides were exclusively found in samples of patients. Another 13, present in controls, were missing. These data indicate that CE-MS can be applied as powerful tool in clinical diagnostics.  相似文献   
10.
Combination of capillary electrophoresis with mass spectrometry (CE-MS) allows generation of polypeptide patterns of body fluids. In a single CE-MS (45 min) run more than 600 polypeptides were analyzed in hemodialysis fluids obtained with different membranes (high-flux/low-flux). Larger polypeptides (M(r) > 10 000) were almost exclusively present in high-flux dialysates only, while in low-flux dialysates additional small polypeptides were detected. Comparison to the normal urine pattern yielded a surprisingly low consensus: a number of polypeptides present in urine were missing. We established a fast and sensitive technique, easily applicable to the monitoring of different modalities of dialyzers.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号