首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
化学   3篇
力学   1篇
数学   1篇
物理学   1篇
  2010年   1篇
  2008年   1篇
  2007年   2篇
  1999年   1篇
  1986年   1篇
排序方式: 共有6条查询结果,搜索用时 149 毫秒
1
1.
Separation and detection of individual submicron polystyrene spheres using capillary electrophoresis with laser-light-scattering detection has been demonstrated. Electrophoretically separated particles were passed through a focused laser beam and light scattered from individual particles was collected at 90 degrees. Each diameter of polystyrene spheres injected (from 110 to 992 nm) resulted in the observation of a well-defined migration window containing multiple peaks, each arising from the light scattered by an individual particle. The migration time window for individual particles of a particular size corresponded well to the migration time of a peak from a population of particles of the same size detected using a UV absorbance detector. The electrophoretic mobility and scattered light intensity were determined for each particle detected. The average scattered light intensity for each particle size was consistent with Mie scattering theory. Particles as small as 110 nm in diameter were detected individually using this method, but particles with a diameter of 57 nm could not be individually detected. The number of single particle scattering events was counted and compared to the theoretical number of particles injected electrokinetically, and the detection efficiency determined ranged from 38 to 57% for polystyrene spheres of different sizes. The laser-light-scattering detection method was directly compared to laser-induced fluorescence detection using fluorescent polystyrene microspheres. The number of particles detected individually by each method was in agreement.  相似文献   
2.
A procedure is explained to determined the amount of several pairs of diametrical loads applied to the outside boundary of a ring when stresses at selected points of the inside or outside boundaries are known. Coefficients of influence are used, following an approach similar to the one presented in a previous paper. Examples of application are given and the possible increase in precision is shown when the number of points of measurements is larger than the number of loads to be determined.  相似文献   
3.
Rezenom YH  Dong J  Murray KK 《The Analyst》2008,133(2):226-232
We have used an infrared laser for desorption of material and ionization by interaction with electrosprayed solvent. Infrared laser-assisted desorption electrospray ionization (IR LADESI) mass spectrometry was used for the direct analysis of water-containing samples under ambient conditions. An ion trap mass spectrometer was modified to include a pulsed Er:YAG laser at 2.94 microm wavelength coupled into a germanium oxide optical fiber for desorption at atmospheric pressure and a nanoelectrospray source for ionization. Analytes in aqueous solution were placed on a stainless steel target and irradiated with the pulsed IR laser. Material desorbed and ablated from the target was ionized by a continuous stream of charged droplets from the electrosprayed solvent. Peptide and protein samples analyzed using this method yield mass spectra similar to those obtained by conventional electrospray. Blood and urine were analyzed without sample pretreatment to demonstrate the capability of IR LADESI for direct analysis of biological fluids. Pharmaceutical products were also directly analyzed. Finally, the role of water as a matrix in the IR LADESI process is discussed.  相似文献   
4.
<正>We propose a scheme to prepare the Bell states for atomic qubits trapped in separate optical cavities via atom-cavity-laser interaction.The quantum information of each qubit is encoded on the degenerate ground states of the atom,so the entanglement between them is relatively stable against spontaneous emission.The proposed scheme consists of a Mach-Zehnder interferometer(MZI) with two arms,and each arm contains a cavity with an N-type atom in it.It requires two classical fields and a single-photon source. By controlling the sequence and time of atom-cavity-laser interaction,the deterministic production of the atomic Bell states is shown.We also introduce the generalization of the present scheme to generate the 2N-atom Greenberger-Horne-Zeilinger state.  相似文献   
5.
This paper studies a parameter estimation problem for the Gurtin-MacCamyequation, which is a nonlinear model of age-dependent populationdynamics. In estimating parameters such as the death rate andthe fertility which depend on the age and the total populationfrom a set of fully discrete observations of the population,we use a backward finite-difference scheme. The function-spaceparameter estimation convergence (FSPEC) of this scheme is provedand numerical simulations are performed.  相似文献   
6.
We have applied desorption electrospray ionization to aerosol particles. Ions were formed from aerosols by merging suspended dry particles with an electrospray of solvent in a modified ion trap mass spectrometer. Dry aerosol particles were generated using a fluidized bed powder disperser and directed toward the inlet of the mass spectrometer. A nanospray source was used to create a spray of solvent droplets directed at the inlet and at a right angle with respect to the aerosol. Ions generated by the interaction of the particles and electrospray were transferred into the ion trap mass spectrometer. Using this method, pure samples of caffeine and erythromycin A were analyzed. In addition, commonly available food and drug powders including instant cocoa powder, artificial sweetener and ibuprofen were analyzed.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号