首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   11篇
  免费   0篇
化学   5篇
数学   6篇
  2015年   1篇
  2012年   2篇
  2011年   2篇
  2010年   1篇
  2009年   2篇
  2007年   1篇
  2006年   1篇
  2002年   1篇
排序方式: 共有11条查询结果,搜索用时 15 毫秒
1.
The main aim of this paper is to show that every GTS can be realized as a μ-closed subspace of a generalized hyperconnected space. Also, we give more characterizations of generalized hyperconnected spaces.  相似文献   
2.
We characterize and discuss the properties of $ \mathcal{I}R $ \mathcal{I}R -closed sets and $ A_{\mathcal{I}R} $ A_{\mathcal{I}R} -sets. Also, we give characterizations of weakly $ \mathcal{I} $ \mathcal{I} -locally closed sets and $ \mathcal{I} $ \mathcal{I} -submaximal spaces. A characterization of codense ideals in terms of $ \mathcal{I}R $ \mathcal{I}R -closed sets is also given.  相似文献   
3.
Our group has used the tetrahydroisoquinoline derivative EDL‐155 to treat glioblastoma in animal models and it is currently being evaluated in the treatment of ocular cancers. The purpose of this study was to develop a rapid and sensitive liquid chromatography and tandem mass spectrometry (LC‐MS/MS) method to study the plasma and vitreous humor disposition of EDL‐155 in rats. Animals received a single periocular injection of EDL‐155 (20 mg/kg). Animals were sacrificed at specified times (5, 60, 120, 240 and 360 min) and plasma and vitreous humor samples were obtained. EDL‐155 was isolated by protein precipitation and the extracts were analyzed by reversed‐phase high‐pressure liquid chromatography (HPLC) with MS/MS detection. A structurally similar analog was used as internal standard (IS). The chromatographic run time was 3.5 min per injection. The mass spectrometer was operated in positive‐ion, multiple reaction monitoring (MRM) mode. The mass transitions monitored were m/z332.2 → 167.2 (EDL‐155) and m/z391.2 → 200.2 (IS). The lower limit of quantification (LLOQ) was 0.1 ng/ml in both vitreous humor and plasma. The method was validated for selectivity, linearity, accuracy and precision in rat vitreous humor and partially validated for accuracy and precision in rat plasma. The ion suppression, recovery and stability of the analyte in the biological matrix were also tested. The assay was rapid, sensitive and robust enough to support EDL‐155 ocular penetration studies in a rodent model of intraocular cancer. Application of this method revealed that EDL‐155 was rapidly passed into the vitreous humor following periocular administration. Further, vitreous humor exposure exceeded systemic exposure by approximately sevenfold. High local concentrations coupled with minimal systemic exposure supports further testing of EDL‐155 as localized therapy for intraocular cancers. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   
4.
In this paper, we investigate uniqueness problems of meromorphic functions concerning differential polynomials sharing non-zero finite value and give some results. As particular cases of our results we deduce some significant results which improve several earlier results of Fang and Hong (2001) [2], Yang and Yi (2003) [7], Lin and Yi (2004) [5] and others.  相似文献   
5.
6.
In this paper, we investigate uniqueness problems of meromorphic functions concerning differential polynomials sharing non-zero finite value and give some results. As particular cases of our results we deduce several earlier results of Fang and Hong (2001) [2], Fang and Hua (1996) [1], Lin and Yi (2004) [5], Yang and Hua (1997) [6] and others.  相似文献   
7.
Unprecedented selective cleavage of the carbon-sulfur bond of the ferrocenylthiosemicarbazone moiety has been observed for the first time, resulting in the formation of mixed geometrical binuclear copper complex [(PPh(3))Cu(μ-S)(2)Cu(PPh(3))(2)]. Upon trying direct synthesis of the title complex, an unusual tetranuclear [Cu(4)(μ(3)-Cl)(4)(PPh(3))(4)] cubane resulted.  相似文献   
8.
9.
A glassy carbon electrode modified with a coating of polypyrrole (Ppy) exhibited an attractive performance for the detection and determination of a non-steroidal and non-narcotic analgesic compound, ketorolac tromethamine (KT). Cyclic voltammetry, differential pulse and square wave voltammetry were used in a combined way to identify the electrochemical characteristics and to optimize the conditions for detection. For calibrating and estimating KT, square-wave voltammetry was mainly used. The drug shows a well-defined peak at -1.40 V vs. Ag/AgCl in the acetate buffer (pH 5.5). The existence of Ppy on the surface of the electrode gives higher electrochemical active sites at the electrode for the detection of KT and preconcentrate KT by adsorption. The square-wave stripping voltammetric response depends on the excitation signal and the accumulation time. The calibration curve is linear in the range 1 x 10(-11) to 1 x 10(-7) M with a detection limit of 1.0 x 10(-12) M. Applicability to serum samples was also demonstrated. A detection limit of 1.0 ng ml for serum was observed. Square-wave voltammetry shows superior performance over UV spectroscopy and other techniques.  相似文献   
10.
A novel 1,4-N→O migration of a disubstituted phenyl ring was observed during N-methylation of a bicalutamide derivative, (2S)-2-(tert-butyldimethylsilanyloxy)-N-(4-cyano-3-trifluoromethylphenyl)-3-(4-fluorophenoxy)-2-methylpropionamide, in the presence of CsF-Celite/acetonitrile and desilylation of (2S)-2-(tert-butyldimethylsilanyloxy)-N-(4-cyano-3-trifluoromethylphenyl)-3-(4-fluorophenoxy)-2,N-dimethylpropionamide in tetra-n-butylammonium fluoride/THF. Both NMR and X-ray analysis confirmed the structure of the 1,4-N→O disubstituted phenyl ring migrated product.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号