排序方式: 共有4条查询结果,搜索用时 15 毫秒
1
1.
Parvateesam Yenda Naresh Kumar Katari Balasubramanian Satheesh Rambabu Gundla Siva Krishna Muchakayala Vijay Kumar Rekulapally 《Journal of separation science》2023,46(11):2200770
The design of an appropriate analytical method for assessing the quality of pharmaceuticals requires a deep understanding of science, and risk evaluation approaches are appreciated. The current study discusses how a related substance method was developed for Nintedanib esylate. The best possible separation between the critical peak pairs was achieved using an X-Select charged surface hybrid Phenyl Hexyl (150 × 4.6) mm, 3.5 μm column. A mixture of water, acetonitrile, and methanol in mobile phase-A (70:20:10) and mobile phase-B (20:70:10), with 0.1% trifluoroacetic acid and 0.05% formic acid in both eluents. The set flow rate, wavelength, and injection volumes were 1.0 ml/min, 285 nm, and 5 μl, respectively, with gradient elution. The method conditions were validated as per regulatory requirements and United States Pharmacopeia general chapter < 1225 >. The correlation coefficient for all impurities from the linearity experiment was found to be > 0.999. The % relative standard deviation from the precision experiments ranged from 0.4 to 3.6. The mean %recovery from the accuracy study ranged from 92.5 to 106.5. Demonstrated the power of the stability-indicating method through degradation studies; the active drug component is more vulnerable to oxidation than other conditions. Final method conditions were further evaluated using a full-factorial design. The robust method conditions were identified using the graphical optimization from the design space. 相似文献
2.
Leela Prasad Kowtharapu Naresh Kumar Katari Christian A Sandoval Siva Krishna Muchakayala Vijay Kumar Rekulapally 《Journal of separation science》2022,45(10):1711-1726
Serotonin receptor antagonist drug Ondansetron hydrochloride injectable formulation containing all related substances was identified and quantified by a single, simple, sensitive, eco-friendly, and green high-performance liquid chromatography method. The disseverment of all impurities was achieved with the Discovery Cyano (250 × 4.6) mm, 5 μm column. The gradient program was composed of pH 5.7 phosphate buffer as mobile phase A and acetonitrile as mobile phase B. The flow rate, column compartment temperature, and detection wavelengths were 0.9 mL/min, 30°C, and 216 nm, respectively. The method was validated as per current regulatory guidelines. The obtained %relative standard deviation for the precision results was between 0.55 and 2.72% for all impurities. The correlation coefficient values from the linearity experiment for impurities and analyte were more than 0.995. The accuracy results were obtained between 88.4 and 113.0% for all impurities. Both sample and standard solutions showed 24 h stability at benchtop and refrigerator conditions. All impurities and analytes met the specificity and mass balance for all forced degradation conditions. Quality-by-design-based design of experiments was utilized to establish the method's robustness. Method greenness was assessed by using the current advanced tool green analytical procedure index, National Environmental Methods Index, and analytical eco-scale. 相似文献
3.
Rekulapally Sriram Chebolu Naga Sesha Sai Pavan Kumar Nerella Raghunandan Vadla Ramesh 《合成通讯》2013,43(23):3419-3428
Abstract A simple and efficient method is described for the oxidation of 7-azaindoles and indoles to 7-azaisatins and isatins using pyridinium chlorochromate–silica gel (PCC-SiO2) with the aid of Lewis acid catalyst aluminium chloride (AlCl3) in dichloroethane. Simplicity of the reaction conditions, easy workup procedure, and good yields are the key features of this protocol. 相似文献
4.
C Vijaya Lakshmi Katari Naresh Kumar M Giri Prasad Kerru Nagaraju Rekulapally Vijay Kumar Jonnalagadda Sreekantha B. 《Russian Journal of General Chemistry》2021,91(12):2539-2545
Russian Journal of General Chemistry - We report an efficient protocol for synthesis of methyl 2-[(tert-butoxycarbonyl) amino]-3-hydroxy-3-phenylpropanoate (Erythro (±)) by simple reduction... 相似文献
1