首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
化学   3篇
数学   2篇
物理学   1篇
  2016年   1篇
  2008年   2篇
  2000年   1篇
  1984年   1篇
  1982年   1篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
2.
Collocation type methods are studied for the numerical solutionof the weakly singular Volterra integral equation of the secondkind: where the solution (t) is assumedto have the form f(t) = x(t)+r?(t), x and being sufficientlysmooth. The solution is approximated near zero by a linear combinationof powers of t?, and away from zero by the usual polynomialrepresentation. Convergence is proved and many numerical experimentsare carried out with examples from the literature. A comparisonis made with a method of Brunner & Norsett (1981), originallydeveloped for (1) with a smooth solution. Special attentionis paid to the numerical approximation of the so-called momentintegrals which emerge in the collocation scheme.  相似文献   
3.
利用XRD、Raman、XPS和FT-IR表征技术,研究无机酸洗脱(HCl、H2SO4、HCl-HF)处理的胜利褐煤微晶结构的变化,采用自行设计的表面吸附仪-GC联用装置,对样品进行不同温度的低温脉冲氧化实验,考察了煤样在不同温度下氧吸附量的变化规律,通过低温脉冲氧吸附规律与TG/DTG和固定床燃烧实验关联,考察了煤样的自燃倾向。结果表明,无机酸洗脱对矿物质的脱除使得煤结构的有序度增加,石墨化程度提高,无机酸洗脱煤样与原煤相比吸氧量明显下降。随着吸附温度的升高,各煤样吸氧量明显增加,且随着脱除矿物质程度的增加,吸氧量呈减小的趋势,导致自燃倾向降低。  相似文献   
4.
The development of a scheme to treat two-dimensional electromagneticscattering by electrically large, perfectly conducting bodiesis described. It incorporates the effects of surface curvatureand non-local phenomena and has the potential to provide thebasis for a general technique yielding more accurate predictionsthan the widely used physical optics method.  相似文献   
5.
Ion-exchange chromatography with ninhydrin detection remains the gold standard for detecting inborn errors of amino acid catabolism and transport. Disadvantages of such analysis include long chromatography times and interference from other ninhydrin-positive compounds. The aim of this project was to develop a more rapid and specific technique using liquid chromatography/tandem mass spectrometry (LC/MS/MS). Optimal fragmentation patterns for 32 amino acids were determined on a triple quadrupole mass spectrometer following butylation. Chromatographic characteristics of each of the amino acids were determined using C8 reversed-phase chromatography with 20% acetonitrile/0.1% formic acid as isocratic mobile phase. Quantitation using eleven deuterated internal standards was compared to cation exchange and ninhydrin detection on a Beckman 7300 system. Following methanol extraction and butylation, determination of 32 amino acids required 20 min. The dynamic range of each amino acid was generally 1-1000 micromol/L. Imprecision ranged from 7 to 23% (CV) over 6 months and recovery ranged from 88-125%. Deming regression with the Beckman 7300 yielded slopes from 0.4-1.2, intercepts from -21 to 65 micromol/L, correlation coefficients from 0.84-0.99 and Syx from 2-125 micromol/L. Isobaric amino acids were separated by chromatography (e.g. leucine, isoleucine) or by unique fragmentation (e.g., alanine, beta-alanine). LC/MS/MS is comparable to traditional LC-ninhydrin detection. Mass spectral detection shortens analysis times and reduces potential for interference in detecting inborn metabolic errors.  相似文献   
6.
The eels of LiF has been measured in the range 0–18 eV with primary beam energies 50 eV and 1.5 keV. Four peaks are clearly resolved in the band gap region at room temperature. The amplitude of the three lower energy loss peaks was found to depend on beam exposure and temperature. It is concluded that the lowest energy peak arises at a beam induced defect, that the next two peaks arise in lithium metal liberated by the electron beam and that the peak nearest to the band edge is due to an intrinsic surface excitation.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号