首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   33篇
  免费   2篇
化学   29篇
力学   1篇
数学   1篇
物理学   4篇
  2023年   3篇
  2021年   2篇
  2020年   2篇
  2019年   5篇
  2018年   2篇
  2017年   2篇
  2016年   5篇
  2015年   1篇
  2014年   1篇
  2013年   4篇
  2012年   1篇
  2010年   1篇
  2008年   2篇
  2007年   1篇
  2006年   1篇
  2004年   2篇
排序方式: 共有35条查询结果,搜索用时 15 毫秒
1.
Liquid chromatography/mass spectrometry (LC/MS)-based proteomics has been used to identify soluble proteins in the bovine adrenal medulla. This gland is a major source of hormones, opioids, neurotransmitters, and several vital proteins. The adrenal medulla proteins were first purified using ammonium sulfate precipitation. The resulting proteins were then pre-fractionated with a C-4 high-performance liquid chromatography (HPLC) column. Each 2-min HPLC fraction was digested with trypsin, and separated further and analyzed using capillary liquid chromatography/tandem mass spectrometry (capLC/nanospray-MS/MS) to map the proteome of the adrenal medulla. The parent mass and sequence ion information thus obtained for tryptic peptides was used to search the NCBInr database using the SEQUEST search engine. A total of 195 proteins were identified, of which 71 had good scores (delta correlation value greater than 0.1, preliminary score above 200, and cross-correlation value above 2.5). The prominent proteins thus identified are secretogranin I precursor, chromogranin A, proenkephalin A precursor, myosin X, hemoglobin beta chain, hemoglobin alpha chain, heat shock protein 10 kDa, and replicase.  相似文献   
2.
Cerium ammonium nitrate (CAN) adsorbed on HNO 3 /silica gel is a mild reagent for selective oxidation of benzylic alcohols to the corresponding aldehydes under microwave irradiation in solventless system.  相似文献   
3.
In this paper, the importance of molecular diffusion versus turbulent transport in the moderate or intense low-oxygen dilution (Mild) combustion mode has been numerically studied. The experimental conditions of Dally et al. [Proc. Combust. Inst. 29 (2002) 1147–1154] were used for modelling. The EDC model was used to describe the turbulence–chemistry interaction. The DRM-22 reduced mechanism and the GRI 2.11 full mechanism were used to represent the chemical reactions of an H2/methane jet flame. The importance of molecular diffusion for various O2 levels, jet Reynolds numbers and H2 fuel contents was investigated. Results show that the molecular diffusion in Mild combustion cannot be ignored in comparison with the turbulent transport. Also, the method of inclusion of molecular diffusion in combustion modelling has a considerable effect on the accuracy of numerical modelling of Mild combustion. By decreasing the jet Reynolds number, decreasing the oxygen concentration in the airflow or increasing H2 in the fuel mixture, the influence of molecular diffusion on Mild combustion increases.  相似文献   
4.
The present study developed a liquid-phase microextraction based on hollow fiber coupled with graphite furnace atomic absorption spectrometry for the effective extraction and quantitation of lead from urine and blood samples. A multivariate design was used for the optimization of the experimental conditions to ensure high extraction efficiency. Six factors (solvent type, chelating agent, time extraction, temperature, donor phase pH, and acceptor phase pH) were obtained by screening eleven factors of the Plackett–Burman design; these were optimized using the central composite design of response surface methodology. The optimum conditions of donor phase pH, acceptor phase pH, temperature, and extraction time were 5, 9.5, 40 °C, and 120 min, respectively. In addition, oleic acid containing dicyclohexyl-18-krone-6 was used for the membrane phase. Under optimal conditions, the enrichment factor, limit of detection, and limit of quantification were obtained in the ranges of 21.3–18.7, 0.001–0.002 ng mL?1, and 0.008–0.01 ng mL?1, respectively, in urine and blood samples. The linearity of the calibration curve was established for the concentration of Pb in the range of 1–50 ng mL?1 (r2?=?0.9983). Finally, the performance of the developed method was evaluated for the determination of lead in urine and blood samples, and satisfactory results were obtained (RSDs <?10% with recovery >?95).  相似文献   
5.

Aims

The objective of this study was to evaluate the potential of 4D flow MRI to assess valve effective orifice area (EOA) in patients with aortic stenosis as determined by the jet shear layer detection (JSLD) method.

Methods and Results

An in-vitro stenosis phantom was used for validation and in-vivo imaging was performed in 10 healthy controls and 40 patients with aortic stenosis. EOA was calculated by the JSLD method using standard 2D phase contrast MRI (PC-MRI) and 4D flow MRI measurements (EOAJSLD-2D and EOAJSLD-4D, respectively). As a reference standard, the continuity equation was used to calculate EOA (EOACE) with the 2D PC-MRI velocity field and compared to the EOAJSLD measurements. The in-vitro results exhibited excellent agreement between flow theory (EOA = 0.78 cm2) and experimental measurement (EOAJSLD-4D = 0.78 ± 0.01 cm2) for peak velocities ranging from 0.9 to 3.7 m/s. In-vivo results showed good correlation and agreement between EOAJSLD-2D and EOACE (r = 0.91, p < 0.001; bias: − 0.01 ± 0.38 cm2; agreement limits: 0.75 to − 0.77 cm2), and between EOAJSLD-4D and EOACE (r = 0.95, p < 0.001; bias: − 0.09 ± 0.26 cm2; limits: 0.43 to − 0.62 cm2).

Conclusion

This study demonstrates the feasibility of measuring EOAJSLD using 4D flow MRI. The technique allows for optimization of the EOA measurement position by visualizing the 3D vena contracta, and avoids potential sources of EOACE measurement variability.  相似文献   
6.
7.
The present study reports the wireless technique that generates asymmetric reactivity on the surface of the conducting substrate without any direct electrical connection in the electrolyte solution by inducing external power. In recent years, bipolar electrochemical systems have received special attention that they are used for new kinds of electrochemical applications ranging from electrodeposition to electroanalytical chemistry. Bipolar electrochemistry is a unique technique because of the lack of direct electrical connection to the bipolar electrode. In this perspective article, we first illustrate the concept and history of the bipolar electrochemistry as well as their application based on the open and closed bipolar configuration in different fields.  相似文献   
8.
A new high efficient and green protocol for the preparation of dihydropyrimido[4,5‐b]quinolinetrione derivatives using magnetically solid acid catalyst was presented. High performance solid acid catalyst was prepared through a three‐step reaction. Firstly, CoFe2O4 nano particles were synthesized using co‐precipitation method. In second step, CoFe2O4 nano particles were coated with SiO2 shell through treatment with tetraethyl orthosilicate (CoFe2O4@SiO2). Finaly, CoFe2O4@SiO2 was modified with polyphosphoric acid (CoFe2O4@SiO2/PPA) in a simple manner. Green reusable catalyst was characterized in details using FTIR, VSM, TEM, FESEM, EDX and used as catalyst for the synthesis of dihydropyrimido[4,5‐b]quinolinetrione derivatives. Reaction was performed under ultrasonic irradiation as green, effective and mild conditions and products were achieved in high to excellent yields. Green and eco‐friendly conditions, short reaction times with high yield of products in addition to easy workup are some merits of presented method.  相似文献   
9.
Abstract

In this work, two polysulfide polymers were synthesized using aromatic organic monomer (α,α′-dichloro-p-xylene) and sodium disulfide (Na2S2) and sodium tetrasulfide (Na2S4) aqueous monomers. Then, the curing process of the polymers was carried out at 170° C using a rheometer. The structural characteristics of synthesized and cured samples were identified by Raman and Fourier transform infrared (FT-IR) spectroscopies. Also, morphological and thermophysical properties of samples were studied by using the X-ray diffraction (XRD) and differential scanning calorimetry (DSC), respectively. Moreover, the molecular weight of the synthesized samples was determined by proton nuclear magnetic resonance (1H NMR). Furthermore, the mechanical properties and hardness of the samples were investigated by tensile test and Shore A. The results showed that in the noncured samples during the increase of sulfur in the polymer structure, solubility was increased whereas it decreased the hardness, melting point (Tm ) and glass transition temperature (Tg ) of polymers. But in cured samples, hardness and Tg increase by increasing sulfur and the mechanical properties also improved. This is due to the increase in crosslinks. Also, Tm and solubility are not observed due to the formation of crosslinks.  相似文献   
10.
A novel and effective potentiometric sensor for the rapid determination of Cd2+ based on carbon paste electrode consisting of the room temperature ionic liquid 1‐butyl‐3‐methylimidazolium hexafluorophosphate, multiwalled carbon nanotubes, silica nanoparticles and ionophore was constructed. The prepared composite has a low potential drift, high selectivity and fast response time, which leads to a more stable potential signal. A linear dynamic range of 4.50×10?9–1.00×10?1 mol L?1 with a detection limit of 2.00×10?9 mol L?1 was obtained. The modified electrode was successfully applied to the accurate determination of trace amounts of Cd2+ in environmental and biological samples.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号