排序方式: 共有11条查询结果,搜索用时 15 毫秒
1.
R Bonfiglio RC King TV Olah K Merkle 《Rapid communications in mass spectrometry : RCM》1999,13(12):1175-1185
A post-column infusion system was developed in order to analyze suppression of electrospray ionization (ESI) tandem mass spectrometry response in the presence of endogenous plasma interferences. By enabling direct detection of these interfering components, this experimental system was used to analyze the ability of several common extraction procedures to remove endogenous plasma components that cause changes in the ESI response of model drug substances. Methyl-t-butyl ether (MTBE) liquid-liquid, Oasis and Empore solid-phase, and acetonitrile (ACN) protein precipitation sample preparation methods were tested using the post-column infusion system. In all cases, ACN protein precipitation samples showed the greatest amount of ESI response suppression while liquid-liquid extracts demonstrated the least. In addition, the three test compounds, phenacetin, caffeine, and a representative Merck compound, demonstrated that ESI response suppression is compound dependent. Suppression was greatest with caffeine, the most polar analyte, and the smallest for the Merck compound, the least polar analyte. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
2.
Samit Mandal J Gerl H Geissel K Hauschild M Hellström Z Janas I Kojouharov Y Kopatch RC Lemmon P Mayet Z Podolyak PH Regan H Schaffner C Schlegel J Simpson HJ Wollersheim 《Pramana》2001,57(1):161-164
Feasibility of gamma-ray spectroscopy at relativistic energies with exotic heavy-ions and new generation of germanium detectors
(segmented Clover) is discussed. An experiment with such detector array and radioactive is discussed. 相似文献
3.
We report measurements of non-linear charge transport in epitaxial (La1−x
Pr
x
)0.7Ca0.3MnO3 thin films fabricated on (100) oriented SrTiO3 single crystals by pulsed laser deposition. The end members of this series, namely Pr0.7Ca0.3MnO3 and La0.7Ca0.3MnO3 are canonical charge-ordered (CO) and ferromagnetic manganites, respectively. The onset of the CO state in Pr0.7Ca0.3MnO3 is manifested by a pronounced insulating behavior below ∼ 200 K. The CO state remains stable even when a large (∼ 2×105 V/cm) electric field is applied across the thin film samples. However, on substitution of Pr with La, a crossover from the
highly resistive CO state to a state of metallic character is observed at relatively low electric fields. The current-voltage
characteristics of the samples at low temperatures show hysteretic and history dependent effects. The electric field driven
charge transport in the system is modelled on the basis of an inhomogeneous medium consisting of ferromagnetic metallic clusters
dispersed in a CO background. 相似文献
4.
MA Freitas SR Dillon RC Dougherty AG Marshall 《Rapid communications in mass spectrometry : RCM》1999,13(15):1622-1625
The self-chemical ionization of diethylzinc is examined by Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry and semiempirical molecular orbital calculations. Electron impact of diethylzinc neutral produces the radical cation, C(4)H(15)Zn(+) (m/z x 122), which reacts further with the neutral (C(2)H(5))(2)Zn to give the following product ions: Zn(+) (m/z x 64), C(2)H(5)Zn(+) (m/z x 93), C(4)H(9)Zn(+) (m/z x 121), C(4)H(11)Zn(2)(+) (m/z x 187), and C(6)H(15)Zn(2)(+) (m/z x 215). To determine the structure and pathways for production of these ions, monoisotopic (12)C(4)H(15)(64)Zn(+), (64)Zn(+) and (12)C(2)H(5)(64)Zn(+) were individually isolated and reacted with the neutral background. We also performed semiempirical molecular orbital calculations (ZINDO/1). The molecular orbital calculations and experimental data are consistent in predicting that the ethyl group on the diethylzinc cation carries the positive charge. Copyright 1999 John Wiley & Sons, Ltd. 相似文献
5.
6.
Blood Compatibility of Multilayered Polyelectrolyte Films Containing Immobilized Gold Nanoparticles
下载免费PDF全文
![点击此处可从《Particle & Particle Systems Characterization》网站下载免费的PDF全文](/ch/ext_images/free.gif)
Arnaud Pallotta Marianne Parent Igor Clarot Ming Luo Vincent Borr Pan Dan Véronique Decot Patrick Menu Ramia Safar Olivier Joubert Pierre Leroy Ariane Boudier 《Particle & Particle Systems Characterization》2017,34(1)
Surface material functionalization including layer‐by‐layer (LbL) polyelectrolyte films with incorporated nanoparticles is a growing field with a wide range of biomedical applications: drug reservoirs, medical devices, or tissue engineering. In parallel, gold nanoparticles (AuNPs) can be grafted by drugs and sensitive molecules using simple protocols. This study shows that AuNP behavior is modified when they are entrapped into three partner LbL films in comparison to the colloidal solution. A polycationic (polyallylamine hydrochloride (PAH)) and a polyanionic (polyacrylic acid (PAA)) polymer is used to build films based on three cycles ((PAH/AuNP/PAA)3). To investigate the interaction with biomolecules and cells, three different films are developed changing the outer layer (either PAH or AuNP or PAA) with the same number of AuNP deposit. The best biocompatibility is observed with a polyacrylic acid outer layer. Due to the high capacity of drug grafting on gold nanoparticles, the results seem promising for the development of nanostructured biomedical devices. 相似文献
7.
Jeremie Gouyon Ariane Boudier Fatima Barakat Arnaud Pallotta Igor Clarot 《Electrophoresis》2022,43(23-24):2377-2391
Taylor dispersion analysis (TDA) is an interesting tool for nanoparticle (NP) size determination, feasible using simple capillary electrophoresis apparatus. Based upon the radial diffusion of analytes upon a laminar stream, the diffusion coefficient of species is easily estimable. Moreover, TDA is generally more adequate than conventional dynamic light scattering methodologies as it is less dependent on the polydispersity of the sample, leading to accurate measurement and reliable results. This review provides every paper mentioning the use of TDA for metallic-based NPs size determination. Diverse strategies for the detection of metallic NPs (like UV–visible and inductively coupled plasma–mass spectrometry – ICP–MS – for instance) and interpretation of the Taylorgrams are discussed. Based upon the literature, advices on future prospects are also indicated, especially for the comparison of TDA results with other classical techniques. 相似文献
8.
We present evidence for a nonsingular origin of the Universe with intial conditions determined by quantum physics and relativistic
gravity. In particular, we establish that the present temperature of the microwave background and the present density of the
Universe agree well with our predictions from these intial conditions, after evolution to the present age using the Einstein-Friedmann
equation. Remarkably, the quantum origin for the Universe naturally allows its evolution at exactly the critical density.
We also discuss the consequences of these results to some fundamental aspects of quantum physics in the early Universe. 相似文献
9.
10.
Ramos L Leal Junior EC Pallotta RC Frigo L Marcos RL de Carvalho MH Bjordal JM Lopes-Martins RÁ 《Photochemistry and photobiology》2012,88(1):154-160
Muscle strains are among the most prevalent causes for athletes' absence from sport activities. Low-level laser therapy (LLLT) has recently emerged as a potential contender to nonsteroidal anti-inflammatory drugs in muscle strain treatment. In this work we investigated effects of LLLT and diclofenac on functional outcomes in the acute stage after muscle strain injury in rats. Muscle strain was induced by overloading the tibialis anterior muscle of rats during anesthesia. The injured groups received either no treatment, or a single treatment with diclofenac 30 min prior to injury, or LLLT (810 nm, 100 mW) with doses of 1, 3, 6 or 9 J, at 1 h after injury. Functional outcome measures included a walking index and assessment of electrically induced muscle performance. All treatments (except 9 J LLLT) significantly improved the walking index 12 h postinjury compared with the untreated group. The 3 J group also showed a significantly better walking index than the drug group. All treatments significantly improved muscle performance at 6 and 12 h. LLLT dose of 3 J was as effective as the pharmacological agent in improving functional outcomes in the early phase after a muscle strain injury in rats. 相似文献