首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   4篇
  免费   0篇
化学   4篇
  2022年   1篇
  2019年   1篇
  2014年   1篇
  2012年   1篇
排序方式: 共有4条查询结果,搜索用时 0 毫秒
1
1.
We investigated a L ‐phenylalanine (L ‐phe) biosensor, functionalized through enzyme immobilization on a polymer‐blend film. The electron mediator 3,4‐dihydroxybenzaldehyde (3,4‐DHB) was employed at the electrode surface to improve direct oxidation of NADH to NAD+ and no additional reagents is required to be added to the sample solution. The bioactivated electrode was coated with a semi‐permeable cellulose acetate membrane in order to prevent dissolution of biofunctionalized polymer‐blend film. This constructed enzyme electrode is the first selective biosensor for phenylketonuria (PKU) detection. The sensitivity of the enzyme electrode was determined as 12.014 mA/M cm2. The Michaelis–Menten and current responses as well as sensitivity of the electrode showed improved values than those of previous works. This selective biosensor presented an excellent electroanalytical response for L ‐phe, with a high steady‐state current being obtained after 20 s. The sensitivity of our biodevice is quite sufficient for the purpose of PKU detection because the reference range of clinical concern for L ‐phenylalanine concentration is CL ‐phe>0.5 mM. This surface‐bioactivated enzyme electrode retained more than 80 % of its electrocatalytic activity after 16 days.  相似文献   
2.
Applied Biochemistry and Biotechnology - Empirical modeling the partition behavior and recovery of a recombinant Pseudomonas putida POS-F84 proline dehydrogenase (ProDH) in aqueous two-phase...  相似文献   
3.
A simple, sensitive aptamer-based biosensor for the detection of phenylalanine is developed using the electrochemical transduction method. For this proposed aptasensor, a 5-thiol-terminated aptamer is covalently attached onto a gold electrode. At the first time, the electrode was evaluated as an electrochemical aptasensor for determination of phenylalanine in aqueous solutions. This sensor was tested in a Tris–HCl buffer with physiological pH?=?7.4 by cyclic voltammetry and differential pulse voltammetry. The detection limit and sensitivity of the modified electrode toward phenylalanine were estimated to be 1 nM (S/N?=?3) and 0.367 μA nM?1, respectively. The linear range of the signal was observed between 1 and 10 nM of phenylalanine with 0.9914 correlation factor. The herein-described approach is expected to promote the exploitation of aptamer-based biosensors for protein assays in biochemical and biomedical studies.  相似文献   
4.
Journal of Solid State Electrochemistry - Screening for hepatitis B is one of the most severe liver virus infections in the world, and due to the effect of early detection and treatment of...  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号