排序方式: 共有19条查询结果,搜索用时 31 毫秒
1.
2.
3.
John F. O'Gara David J. Williams William J. Macknight Frank E. Karasz 《Journal of Polymer Science.Polymer Physics》1987,25(7):1519-1536
The sodium salts of randomly sulfonated polysulfone (Na-SPSF), derived from 1,1′-sulfonylbis-[4-chlorobenzene] with 4,4′-(1-methylethylidene)-bis-[phenol], were prepared over the composition range of 3–30 mol% sodium sulfonate, using improved procedures in which the sulfonating complex was introduced into an intensely agitated polymer solution. In contrast to earlier work, Tg was found to increase nonlinearly with sodium sulfonate content. A SAXS study provided no evidence of ionic clustering in these polymers. Binary blends of Na-SPSFs differing only in composition were prepared by casting films from solution, and their phase behavior was studied by dynamic mechanical analysis after annealing at 250°C. It was found that the blends were miscible up to a composition difference of about 9–10 mol% sodium sulfonate. Using this fact it was possible to calculate a value for χABn of 200–250, where χAB represents the segmental interaction parameter between unmodified and modified repeat units, and n is the degree of polymerization. Uncertainty in the degree of ionic association places a degree of uncertainty on the effective value of n and therefore on χAB. The product, however, is independent of any assumptions regarding molecular associations. 相似文献
4.
5.
A rapid capillary electrophoretic (CE) method was developed for the determination of phloroglucinol compounds, monoacetylphloroglucinol (MAPG) and 2,4-diacetylphloroglucinol (DAPG), in microbial supernatants of Pseudomonas fluorescens F113 over a 24-h growth cycle. Prior to electrophoretic separation, solid-phase extraction of supernatant samples on octadecylsilica for the purpose of sample cleanup is recommended. The optimum electrophoretic conditions were found to be 25 mM sodium tetraborate running buffer at pH 9.3, temperature at 25 degrees C with an applied voltage of 25 kV. The capillary was an Agilent fused-silica capillary of total length 33 cm x 50 microm inner diameter, 375 microm outer diameter, with effective length 24.5 cm. While MAPG and DAPG were monitored at selected wavelengths in the range of 214-320 nm, analysis at 214 nm was used and a CE separation time of less than 2 min was achieved. A partial method validation study was performed in accordance with European Agency for Evaluation of Medicinal Products (EMEA) guidelines. The method displayed linearity over the investigated range of 10-200 microg/mL, with limits of detection of 1.2 microg/mL for MAPG and 1.3 microg/mL for DAPG. 相似文献
6.
7.
O'Gara JE Alden BA Gendreau CA Iraneta PC Walter TH 《Journal of chromatography. A》2000,893(2):245-251
As part of our program to develop more stable cyano (CN) high-performance liquid chromatography (HPLC) column packings, we have evaluated hydrolytic stability as a function of ligand connectivity, chain length, and side group steric protection and the pH of the mobile phase. Three accelerated tests were used to evaluate stability: (1) A non-HPLC screening test measuring carbon loss in refluxing MeOH-100 mM KH2PO4 pH 4.5 (1:1, v/v) solution; (2) a continuous flow HPLC test measuring capacity factor maintenance in 1% trifluoroacetic acid in water (pH 1.02) at 80 degrees C; and (3) a continuous flow HPLC test measuring column efficiency maintenance in 50 mM triethylamine in water (pH 10.00) at 50 degrees C. The stability of the CN phases was found to be dependent on both ligand chemical structure and the pH of the test conditions. The starting screen test of intermediate pH was least able to differentiate the CN phases based on structure, because two different degradation mechanisms appear to offset each other (acid induced siloxane bond cleavage vs. base induced silica dissolution). A trifunctional and a sterically protected CN phase were notably stable under the acidic test conditions, but had poor stability under basic conditions. Conversely, chain extension afforded poor stability under acidic conditions, but did afford improved stability at higher pH. In total, the data indicate that good CN column stability can be achieved by using a trifunctional or a sterically protected phase in acidic mobile phases. However, as mobile phases of intermediate or higher pH are employed, shorter column lifetimes can be expected due to an accelerated dissolution of the underlying silica substrate. Materials were also compared chromatographically using a mixture of non-polar, polar, and basic analytes under reversed-phase conditions. 相似文献
8.
9.
10.