首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
化学   7篇
数学   1篇
  2017年   1篇
  2016年   1篇
  2012年   2篇
  2011年   1篇
  2009年   1篇
  2007年   1篇
  1999年   1篇
排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
A sensitive and selective separation of common anionic constituents of atmospheric aerosols, sulfate, nitrate, chloride, and oxalate, is presented using microchip electrophoresis. The optimized separation is achieved in under 1 min and at low background electrolyte ionic strength (2.9 mM) by combining a metal-binding electrolyte anion (17 mM picolinic acid), a sulfate-binding electrolyte cation (19 mM HEPBS), a zwitterionic surfactant with affinity towards weakly solvated anions (19 mM N-tetradecyl,N,N-dimethyl-3-ammonio-1-propansulfonate), and operation in counter-electroosmotic flow (EOF) mode. The separation is performed at pH 4.7, permitting pH manipulation of oxalate's mobility. The majority of low-concentration organic acids are not observed at these conditions, allowing for rapid subsequent injections without the presence of interfering peaks. Because the mobilities of sulfate, nitrate, and oxalate are independently controlled, other minor constituents of aerosols can be analyzed, including nitrite, fluoride, and formate if desired using similar separation conditions. Contact conductivity detection is utilized, and the limit of detection for oxalate (S/N = 3) is 180 nM without stacking. Sensitivity can be increased with field-amplified sample stacking by injecting from dilute electrolyte with a detection limit of 19 nM achieved. The high-sensitivity, counter-EOF operation, and short analysis time make this separation well-suited to continuous online monitoring of aerosol composition.  相似文献   
2.
In many generic combustion models, one finds that a combustionwave will develop with a specific wave speed. However, thereare possible initial temperature profiles which do not evolveinto such waves, but rather die out to the ambient temperature.There can exist, in some models, a clear distinction betweenthose initial conditions that do evolve into combustion wavesand those that do not; this is sometimes referred to as thewatershed initial condition. When fuel consumption is consideredto be negligible, analytical methods can be used to obtain theexact watershed. In this paper, we consider the problem of determiningpseudo-watersheds and ascertaining the relationship betweenthese pseudo-watersheds and the exact watersheds. In the processa novel weight-function approach for infinite spatial domainsis developed.  相似文献   
3.
The use of mixtures of ionic and zwitterionic surfactants in poly(dimethylsiloxane) (PDMS) microchips is reported. The effect of surfactant concentration on electroosmotic flow (EOF) was studied for a single anionic surfactant (sodium dodecyl sulfate, SDS), a single zwitterionic surfactant (N-tetradecylammonium-N,N-dimethyl-3-ammonio-1-propanesulfonate, TDAPS), and a mixed SDS/TDAPS surfactant system. SDS increased the EOF as reported previously while TDAPS showed an initial increase in EOF followed by a reduction at higher concentrations. When TDAPS was added to a solution containing SDS, the EOF decreased in a concentration-dependent manner. The EOF for all three surfactant systems followed expected pH trends, with increasing EOF at higher pH. The mixed surfactant system allowed tuning of the EOF across a range of pH and concentration conditions. After establishing the EOF behavior, the adsorption/desorption kinetics were measured and showed a slower adsorption/desorption rate for TDAPS than SDS. Finally, the separation and electrochemical detection of model catecholamines in buffer and reduced glutathione in red blood cell lysate using the mixed surfactant system were explored. The mixed surfactant system provided shorter analysis times and/or improved resolution when compared to the single surfactant systems.  相似文献   
4.
The use of surfactant mixtures to affect both EOF and separation selectivity in electrophoresis with PDMS substrates is reported, and capacitively coupled contactless conductivity detection is introduced for EOF measurement on PDMS microchips. First, the EOF was measured for two nonionic surfactants (Tween 20 and Triton X‐100), mixed ionic/nonionic surfactant systems (SDS/Tween 20 and SDS/Triton X‐100), and finally for the first time, mixed zwitterionic/nonionic surfactant systems (TDAPS/Tween 20 and TDAPS/Triton X‐100). EOF for the nonionic surfactants decreased with increasing surfactant concentration. The addition of SDS or TDAPS to a nonionic surfactant increased EOF. After establishing the EOF behavior, the separation of model catecholamines was explored to show the impact on separations. Similar analyte resolution with greater peak heights was achieved with mixed surfactant systems containing Tween 20 and TDAPS relative to the single surfactant system. Finally, the detection of catecholamine release from PC12 cells by stimulation with 80 mM K+ was performed to demonstrate the usefulness of mixed surfactant systems to provide resolution of biological compounds in complex samples.  相似文献   
5.
Measurement variance is a crucial aspect of quantitative chemical analysis. Variance directly affects important analytical figures of merit, including detection limit, quantitation limit, and confidence intervals. Most reported analyses for emerging analytical techniques implicitly assume constant variance (homoskedasticity) by using unweighted regression calibrations. Despite the assumption of constant variance, it is known that most instruments exhibit heteroskedasticity, where variance changes with signal intensity. Ignoring nonconstant variance results in suboptimal calibrations, invalid uncertainty estimates, and incorrect detection limits. Three techniques where homoskedasticity is often assumed were covered in this work to evaluate if heteroskedasticity had a significant quantitative impact—naked-eye, distance-based detection using paper-based analytical devices (PADs), cathodic stripping voltammetry (CSV) with disposable carbon-ink electrode devices, and microchip electrophoresis (MCE) with conductivity detection. Despite these techniques representing a wide range of chemistries and precision, heteroskedastic behavior was confirmed for each. The general variance forms were analyzed, and recommendations for accounting for nonconstant variance discussed. Monte Carlo simulations of instrument responses were performed to quantify the benefits of weighted regression, and the sensitivity to uncertainty in the variance function was tested. Results show that heteroskedasticity should be considered during development of new techniques; even moderate uncertainty (30%) in the variance function still results in weighted regression outperforming unweighted regressions. We recommend utilizing the power model of variance because it is easy to apply, requires little additional experimentation, and produces higher-precision results and more reliable uncertainty estimates than assuming homoskedasticity.  相似文献   
6.
We report herein the synthesis of cytotoxic cyanobactin, Wewakazole B through an efficient solution-phase approach. The key steps of the synthesis are the macrocyclic lactamization of linear dodecapeptide and construction of two hexapeptides with three different substituted oxazole rings.  相似文献   
7.
Capillary zone electrophoresis is a proven method for separating small ions because of the inherent charge and differences in mobility of these analytes. Despite its resolving power, CZE can be insufficient for separating ions with similar mobilities. One remedy is to modify mobilities via the addition of background electrolyte complexation agents. However, this approach is not straightforward for inorganic anions, which lack complexation options. To address this shortfall, the diprotonated diamine moiety was investigated for complexation of dianions. Dicationic diamines significantly complexed dianions, and this interaction was not purely electrostatic in nature because affinities varied with dianion identity. Aqueous association constants were measured with affinity capillary electrophoresis (ACE) and found to be similar in magnitude but different in selectivity to those of dianions with magnesium ion. Binding was also investigated for zwitterionic buffers containing the protonated diamine moiety. Zwitterions exhibited binding constants as high as 18 M?1 (30‐mM ionic strength). This work discusses the observed binding constants and their potential usefulness in CZE separations of inorganic anions. Also covered are improvements to ACE methodology and an evaluation of some of the assumptions employed.  相似文献   
8.
The ability to monitor and quantify anionic components of aerosols is important for developing a better fundamental understanding of temporal and spatial variations in aerosol composition. Of the many methods that can be used to detect anions, capillary electrophoresis is among the most attractive ones because of its high separation efficiency, high resolving power for ionic compounds, and ability to be miniaturized for in-field monitoring. Here we present a method to baseline resolve common aerosol components nitrate, sulfate, chloride, and over two dozen organic acids in a single separation. A capillary electrophoresis separation utilizing a pH 5.78 piperazine buffer with 1,5-naphthalenedisulfonic acid as a probe for indirect UV absorbance detection was developed for this analysis. Previously, two different buffers were required to adequately separate all of these compounds. Electrophoretic mobilities, limits of detection, and migration time reproducibilities were measured for 38 organic and 8 inorganic anions. For solutions of low conductivity, detection limits for electrokinetic injections were found to be up to two orders of magnitude lower (0.2-0.4 microM) than those for pressure injection (1-45 microM). This separation was optimized and used for routine analysis of aqueous extracts of ambient atmospheric aerosols, but may be extended to other samples containing similar mixtures of anions.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号