首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   16篇
  免费   0篇
化学   5篇
力学   1篇
物理学   10篇
  2014年   1篇
  2013年   1篇
  2011年   1篇
  2010年   1篇
  2009年   2篇
  1999年   1篇
  1997年   1篇
  1994年   1篇
  1993年   3篇
  1992年   1篇
  1988年   1篇
  1987年   1篇
  1980年   1篇
排序方式: 共有16条查询结果,搜索用时 46 毫秒
1.
2.
3.
4.
The applicability of ultra-performance liquid chromatography (UPLC) combined with full-scan accurate mass time-of-flight (TOF) and Orbitrap mass spectrometry (MS) to the analysis of hormone and veterinary drug residues was evaluated. Extracts from blank bovine hair were fortified with 14 steroid esters. UPLC-Orbitrap MS performed at a resolving power of 60,000 (FWHM) enabled the detection and accurate mass measurement (<3 ppm error) of all 14 steroid esters at low ng/g concentration level, despite the complex matrix background. A 5 ppm mass tolerance window proved to be essential to generate highly selective reconstructed ion chromatograms (RICs) having reduced background from the hair matrix. UPLC-Orbitrap MS at a lower resolving power of 7500 and UPLC-TOFMS at mass resolving power 10,000 failed both to detect all of the steroid esters in hair extracts owing to the inability to mass resolve analyte ions from co-eluting isobaric matrix compounds. In a second application, animal feed extracts were fortified with coccidiostats drugs at levels ranging from 240 to 1900 ng/g. UPLC-Orbitrap MS conducted at a resolving power of 7500 and 60,000 and UPLC-TOFMS detected all of the analytes at the lowest investigated level. Thanks to the higher analyte-to-matrix background ratio, the utilization of very narrow mass tolerance windows in the RIC was not required. This study demonstrates that even when the targeted sample preparation from conventional LC-MS/MS is applied to UPLC with full-scan accurate mass MS, false compliant (false negative) results can be obtained when the mass resolving power of the MS is insufficient to separate analyte ions from isobaric co-eluting sample matrix ions. The current trend towards more generic and less selective sample preparation is expected to aggravate this issue further.  相似文献   
5.
Of all the elements, hydrogen has the largest naturally occurring variations in the ratio of its stable isotopes (D/H). It is for this reason that there has been a strong desire to add hydrogen to the list of elements amenable to isotope ratio monitoring gas chromatography/mass spectrometry (irm-GC/MS). In irm-GC/MS the sample is entrained in helium as the carrier gas, which is also ionized and separated in the isotope ratio mass spectrometer (IRMS). Because of the low abundance of deuterium in nature, precise and accurate on-line monitoring of D/H ratios with an IRMS requires that low energy helium ions be kept out of the m/z 3 collector, which requires the use of an energy filter. A clean mass 3 (HD(+.)) signal which is independent of a large helium load in the electron impact ion source is essential in order to reach the sensitivity required for D/H analysis of capillary GC peaks. A new IRMS system, the DELTA(plus)XL(trade mark), has been designed for high precision, high accuracy measurements of transient signals of hydrogen gas. It incorporates a retardation lens integrated into the m/z 3 Faraday cup collector. Following GC separation, the hydrogen bound in organic compounds must be quantitatively converted into H(2) gas prior to analysis in the IRMS. Quantitative conversion is achieved by high temperature conversion (TC) at temperatures >1400 degrees C. Measurements of D/H ratios of individual organic compounds in complicated natural mixtures can now be made to a precision of 2 per thousand (delta notation) or, better, with typical sample amounts of approximately 200 ng per compound. Initial applications have focused on compounds of interest to petroleum research (biomarkers and natural gas components), food and flavor control (vanillin and ethanol), and metabolic studies (fatty acids and steroids). Copyright 1999 John Wiley & Sons, Ltd.  相似文献   
6.
Nawab Singh  AW Joshi 《Pramana》1980,14(2):159-163
Pressure variation of maximumF-band absorption energies in the halides of lithium, sodium and potassium has been investigated employing the extended-ion approximation for the calculation of theF-electron energy eigenvalues and using values of local compressibility in the neighbourhood of theF-centres which include the effect of vacancy and pressure. The results obtained agree with the experimental results.  相似文献   
7.
Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionization (DESI) mass spectrometry (MS). In this work the feasibility of DESI application for the rapid screening of intact esters of anabolic steroids in bovine hair has been studied. Using a linear ion trap both full scan and data-dependent collision induced dissociation MS(n) spectra were acquired in minutes for testosterone cypionate, testosterone decanoate and estradiol benzoate standard solutions deposited on a glass or PTFE surface. However direct analysis of incurred hair failed due to inefficient desorption ionization and the minute quantities of steroid esters present. Therefore a simplified ultrasonic liquid extraction procedure was developed, allowing rapid DESI analysis of a few microliters of the concentrate and a total analysis time of 2-4h per batch instead of 3 days. The potential of this DESI approach is clearly demonstrated by MS(3) data from hair samples incurred with high levels (300-800 μg kg(-1)) of steroid esters, levels which do occur in samples from controlled- and illegally treated animals. For much lower levels state-of-the-art ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) screening methods remain the method of choice and might benefit from the proposed simplified extraction as well.  相似文献   
8.
9.
The abuse of synthetic esters of natural steroids such as testosterone and estradiol in cattle fattening and sports is hard to detect via routine urine testing. The esters are rapidly hydrolysed in vivo into substances which are also endogenously present in urine. An interesting alternative can be provided by the analysis of the administered synthetic steroids themselves, i.e., the analysis of intact steroid esters in hair by liquid chromatography tandem mass spectrometry (LC/MS/MS). However, retrospective estimation of the application date following a non-compliant finding is hindered by the complexity of the kinetics of the incorporation of steroid esters in hair. In this study, the incorporation of intact steroid esters in hair following pour-on treatment has been studied and critically compared with results from intramuscular treatment. To this end animals were pour-on treated with a hormone cocktail containing testosterone cypionate, testosterone decanoate and estradiol benzoate in different carriers. The animals were either treated using injection and pour-on application once or three times having 1 week between treatments using injection and pour-on application. Animals were slaughtered from 10–12 weeks after the last treatment. Both hair and blood plasma samples were collected and analysed by LC/MS/MS. From the results, it is concluded that after single treatment the levels of steroid esters in hair drop to CCβ levels (5–20 μg/kg) after 5–7 weeks. When treatment is repeated two times, the CCβ levels are reached after 9–11 weeks. Furthermore, in plasma, no steroid esters were detected; not even at the low microgramme per litre level but—in contrast with the pour-on application—after i.m. injection, significant increase of 17β-testosterone and 17β-estradiol were observed. These observations suggest that transport of steroid esters after pour-on application is not only performed by blood but also by alternative fluids in the animal so probably the steroid esters are already hydrolysed and epimerized before entering the blood.  相似文献   
10.
Biological tests can be used to screen samples for large groups of compounds having a particular effect, but it is often difficult to identify a specific compound when a positive effect is observed. The identification of an unknown compound is a challenge for analytical chemistry in environmental analysis, food analysis, as well as in clinical and forensic toxicology. In this study bioassay-guided fractionation, ultra high performance liquid chromatography combined with time-of-flight mass spectrometry (UHPLC/TOFMS) and accurate mass database searching was tested to detect and identify unknown androgens. Herbal mixtures and sport supplements were tested using an androgen bioassay and modifications in sample preparations were carried out in order to activate inactive pro-androgens, androgen esters and conjugated androgens to enable their detection in the bioassay. Two of the four herbal mixtures tested positive and bioassay-guided fractionation followed by UHPLC/TOFMS of positive fractions resulted in the identification of nortestosterone phenylpropionate, testosterone cyclohexanecarboxylate and methyltestosterone. Three of the four sport supplements reacted toxic in the bioassay or gave inconclusive results and were further investigated using UHPLC/TOFMS in combination with data processing software and an accurate mass database having approximately 40,000 entries. This accurate mass database was derived from the PubChem database on the internet and coupled to the TOFMS software. This resulted in the tentative identification of several androgens, including methylboldenone, testosterone and the androgen esters methyltestosterone propionate or testosterone isobutyrate, testosterone buciclate and methylenetestosterone acetate. The study showed that bioassay-guided fractionation in combination with UHPLC/TOFMS analysis is a useful procedure to detect, isolate and identify unknown androgens in suspected samples. As an alternative, the use of data processing software in combination with an accurate mass database and coupled on-line with the TOFMS instrument software enabled the identification of androgens and androgen esters in the chromatogram even without bioassay-guided fractionation.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号