首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
化学   7篇
  2013年   1篇
  2006年   1篇
  2001年   1篇
  1999年   1篇
  1997年   3篇
排序方式: 共有7条查询结果,搜索用时 15 毫秒
1
1.
A simple and very sensitive method has been developed for the determination of ascorbic acid based on the oxidation of ascorbic acid to dehydroascorbic acid by iron(III), followed by a complexation of iron(II) with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol(Br-PADAP). The iron(II) complex is formed immediately, with absorption maxima at 560 and 748 nm and a molar absorptivity of 1.31 × 105 l mole–1cm–1 and 5.69 × 104 l mole–1cm–1, respectively. The ascorbic acid determination is possible with a linear range up to 2.4 μg ml–1, a calibration sensitivity of 0.744 ml μg–1 at 560 nm and 0.323 ml μg–1 at 748 nm, and a detection limit of 15 ng ml–1 and 44 ng ml–1, respectively. The procedure was used for the ascorbic acid determination in several fruit juices and pharmaceutical formulations. The results demonstrated a good precision (R.S.D. < 1%) and are in agreement with those obtained with others methods. The Br-PADAP method proposed is six times more sensitive than the method using the iron(II)-1,10-phenanthroline system. Received: 7 May 1996 / Revised: 1 July 1996 / Accepted: 8 August 1996  相似文献   
2.
A supported liquid membrane (SLM) method for the speciation of chromium has been developed. The method is based on selective extraction and enrichment of anionic Cr(VI) and cationic Cr(III) species in two serially connected SLM units. Methyltricaprylammonium chloride (Aliquat) and di-(2-ethylhexyl) phosphoric acid (DEHPA), respectively were used as the selective extractants in the membrane liquid. Graphite furnace atomic absorption spectrometry (GFAAS) was utilised for final determination. Optimised conditions for the DEHPA membrane were, sample solution at pH 3, acceptor solution 0.1 M HNO3 and 10% w/w carrier in kerosene. The corresponding values for the Aliquat membrane were pH 7, 0.75 M HNO3 and 6% w/w carrier in di-n-hexylether. This gave extraction efficiencies for Cr(III) and Cr(VI) of 90 and 40%, respectively. The method was used to measure the concentration of Cr III and Cr VI in surface water from an abandoned tannery site. Storage experiments at different pH showed that preservation at neutral pH gave almost constant values over a period of one month. At acidic pH (pH=3.0) the concentration of Cr(VI) decreased rapidly while the concentration of Cr(III) increased. The detection limit, expressed as three times the standard deviation of enriched blank samples was 0.01 μg l−1.  相似文献   
3.
Abstract

The performance of a flow-through mercury coated reticulated vitreous carbon (RVC) electrode in the potentiometric stripping analysis (PSA) of trace metals has been examined. A wall-jet glassy carbon cell was used for the comparative experiments. Experimental parameters influencing the stripping signals have been optimised in order to use the stripping analysis after the preconcentration and matrix isolation by supported liquid membrane (SLM) technique. The SLM with di-2-ethylhexyl-phosphoric acid (DEHPA) as the extractant in the membrane liquid for proton driven transport of trace metals across the membrane has been chosen. Results presented for lead determination in river water demonstrate the analytical advantages of coupled technique SLM-PSA.  相似文献   
4.
Lead is recognized worldwide as a poisonous metal. Thus, the determination of this element is often required in environmental, biological, food and geological samples. However, these analyses are difficult because such samples contain relatively low concentrations of lead, which fall below the detection limit of conventional analytical techniques such as flame atomic absorption spectrometry and inductively coupled plasma optical emission spectrometry. Several preconcentration procedures to determine lead have therefore been devised, involving separation techniques such as liquid-liquid extraction, solid phase extraction, coprecipitation and cloud point extraction. Citing 160 references, this paper offers a critical review of preconcentration procedures for determining lead using spectroanalytical techniques.  相似文献   
5.
A procedure is proposed for the separation and determination of molybdenum in iron matrices by a batch process. It is based on the solid-phase extraction of the molybdenum(V) ion as thiocyanate complex on polyurethane (PU) foam. The extraction parameters were optimized. Using 0.20 mol L–1 hydrochloric acid, a thiocyanate concentration of 0.10 mol L–1, 100 mg of polyurethane foam and shaking time of 10 min, molybdenum (5–400 μg) can be separated and preconcentrated from large amounts of iron (10 mg). Desorption was carried out instantaneously by conc. nitric acid or acetone. Distribution coefficients, sorption capacity of the PU foam and coefficients of variation were also evaluated. The effect of some ions on the separation procedure was assessed. Iron(III) should be reduced to iron(II). The proposed procedure was used to determine molybdenum in standard iron matrices such as steel and pure iron. The achieved results did not show significant differences with certified values.  相似文献   
6.
Metal ions were preconcentrated from water samples using supported liquid membranes containing 40% w/w di-2-ethylhexyl phosphoric acid (DEHPA) dissolved in kerosene as the membrane liquid. The driving force for the mass transport of analytes in this system is the pH gradient across the membrane. The effect of the carrier concentration on the extraction efficiency was studied. The mechanism for the mass transport in the system was investigated by measuring changes in pH and analyte ion concentration as well as changes in the concentration of other interfering metal ions present in large excess during the enrichment. The extraction efficiency was found to be unchanged as long as the pH difference across the membrane was more than 2 pH units. The long-term stability of the system was investigated at different pHs in the donor solution. Under optimal conditions, the membrane was stable for at least 200 h with reagent water samples and at least 80 h for river water samples. Enrichment factors of approximately 15 times could be obtained. The corresponding extraction efficiencies were over 80% for some of the investigated metal ions. The detection limits of blank samples for Cu2+, Cd2+ and Pb2+ using 120 min processing time were 0.19, 0.024 and 0.09 ng/mL, respectively. Received: 29 October 1996 / Revised: 17 February 1997 / Accepted: 23 February 1997  相似文献   
7.
A simple and very sensitive method has been developed for the determination of ascorbic acid based on the oxidation of ascorbic acid to dehydroascorbic acid by iron(III), followed by a complexation of iron(II) with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol(Br-PADAP). The iron(II) complex is formed immediately, with absorption maxima at 560 and 748 nm and a molar absorptivity of 1.31 × 105 l mole–1cm–1 and 5.69 × 104 l mole–1cm–1, respectively. The ascorbic acid determination is possible with a linear range up to 2.4 μg ml–1, a calibration sensitivity of 0.744 ml μg–1 at 560 nm and 0.323 ml μg–1 at 748 nm, and a detection limit of 15 ng ml–1 and 44 ng ml–1, respectively. The procedure was used for the ascorbic acid determination in several fruit juices and pharmaceutical formulations. The results demonstrated a good precision (R.S.D. < 1%) and are in agreement with those obtained with others methods. The Br-PADAP method proposed is six times more sensitive than the method using the iron(II)-1,10-phenanthroline system. Received: 7 May 1996 / Revised: 1 July 1996 / Accepted: 8 August 1996  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号