首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   0篇
化学   14篇
  2013年   1篇
  2011年   2篇
  2010年   3篇
  2009年   1篇
  2008年   2篇
  2007年   4篇
  2005年   1篇
排序方式: 共有14条查询结果,搜索用时 31 毫秒
1.
Based on the separation selectivity equation, related to the dimensionless parameters for fully charged achiral analytes using a neutral CD, the separation selectivity can be classified into seven patterns. With respect to CZE without CD, the presence of CD in the buffer may improve, or reduce, the separation selectivity with this effect being accompanied by the same or reversed electrophoretic mobility order for charged analytes. This can depend on the separation selectivity of the two analytes in free solution, the binding selectivity, the separation selectivity of analyte–CD complexes and the ratio of electrophoretic mobility of the analytes in free, and complexed forms. Using positional isomers of benzoic acids and phenoxy acids as test analytes and α‐CD as a selector, the observed separation selectivity shapes were found to be in excellent agreement with the predicted separation selectivities.  相似文献   
2.
A multiresidue method suitable for confirmation and determination of six sulfonamides (SAs), three tetracyclines (TCs), and pyrimethamine (PYR) in cow milk was validated. Milk samples were extracted using copolymer Oasis HLB solid-phase extraction (SPE) and analyzed by liquid chromatography-electrospray mass spectrometry with positive ion mode. Estimated method detection limits (MDL) and method quantitation limits (MQL) ranged from 0.48 to 2.64 and 0.61 to 8.64ng/mL, respectively. These values are far lower than the maximum residue limits (MRLs) established by several control authorities. Excellent linear dynamic range was observed from the method quantitation limits to 300ng/mL with correlation coefficients better than 0.9900 for all compounds. The method was accurate with recoveries ranging from 72.01 to 97.39%. Good intra-precision and intermediate precision were obtained with RSD better than 11.08%. The method is fairly robust with sample pH being the only critical control point.  相似文献   
3.
Stationary phase selectivities for halogenated compounds in reversed-phase HPLC were compared using C18 monolithic silica capillary columns modified with poly(octadecyl methacrylate) (ODM) and octadecyl moieties (ODS). The preferential retention of halogenated benzenes on ODM was observed in methanol/water and acetonitrile/water mobile phases. In selectivity comparison of selected analytes on ODM and ODS, greater selectivities for halogenated compounds were obtained with respect to alkylbenzenes on an ODM column, while similar selectivities were observed with a homologous series of alkylbenzenes on ODM and ODS columns. These data can be explained by greater dispersive interactions by more densely packed octadecyl groups on the ODM polymer coated column together with the contribution of carbonyl groups in ODM side chains. For the positional isomeric separation of dihalogenated benzenes (ortho-, meta-, para-), the ODM column also provided better separation of these isomers for the adjacently eluted isomers that cannot be completely separated on an ODS column in the same mobile phase. These results imply that the ODM column can be used as a better alternative to the ODS column for the separation of other halogenated compounds.  相似文献   
4.
A gradient reversed-phase liquid chromatography with fluorescence detection method for simultaneous identification and quantification of bisphenol-A-diglycidyl ether (BADGE), bisphenol-F-diglycidyl ether (BFDGE), and their 10 derivatives in food matrixes was developed and validated for the analysis of oil-in-water- and aqueous-based foodstuffs. The method linearity range 0.016-10 ppm which are hundred-fold below and tenfold above the EU restriction at 1 ppm (mg/kg). The method detection limits range 0.72-4.20 ppb and the method quantitation limits range 2.40-14.85 ppb, respectively. The validation data indicate excellent precision, acceptable recovery, and good robustness, all supporting a good potential to further develop the method as a standard method for the determination of migrations from interior can coatings into foodstuffs.  相似文献   
5.
A carrier-mediated supported liquid membrane micro-extraction using single hollow fiber membrane suitable for the determination of the herbicide glyphosate and its main metabolite aminomethylphosphonic acid in water is reported. A solution of 0.20 M Aliquat-336, a cationic carrier, in di-n-hexyl ether was selected as the supported liquid. A 20 microL of 1.0 M potassium chloride as the acceptor phase was filled in the membrane lumen. The membrane was immersed in a 20 mL of pH 9.0 sample solution. After 60-min extraction, the acceptor phase was analyzed by high-performance liquid chromatography with post-column derivatization. The enrichment factors were found to be 853 and 136 for glyphosate and aminomethylphosphonic acid, respectively. The method detection limits are 0.22 microg/L for glyphosate and 3.40 microg/L for aminomethylphosphonic acid. The procedure was validated and showed good accuracy and precision over a large linear dynamic range. The validated method was tested for the analysis of both analytes in spiked groundwater with good success.  相似文献   
6.
This paper describes a systematic approach to the development of a solid-phase extraction method for simultaneous extraction of 10 antibiotic residues in bovine milk, belonging to groups of sulfonamides, tetracyclines, and pyrimethamine. The sample preparation steps include acidic deproteinization of milk proteins followed by sample enrichment and cleanup using a polymer-based Oasis HLB solid-phase extraction cartridge. The analyses were carried out by using a method based on liquid chromatography-electrospray ionisation-mass spectrometry with positive ion mode. The parameters affecting the extraction efficiency such as sample loading pH, SPE wash solvent composition, and eluting solution pH were carefully investigated and optimized. The developed solid-phase extraction procedure coupled to multiresidue liquid chromatography-electrospray ionization-mass spectrometry method was applied for the analysis of 10 antibiotic residues in milk samples, and it proved to be simple, sensitive, and selective providing a recovery ranging from 70 to 106%.  相似文献   
7.
A method has been developed for carrier-mediated hollow-fiber liquid-phase microextraction (HF-LPME) and enrichment of multiple classes of antibiotics in water samples. Eleven compounds (erythromycin, spiramycin, tilmicosin, sulfathiazole, sulfamethazine, sulfamerazine, oxytetracycline, tetracycline, ciprofloxacin, danofloxacin and enrofloxacin) from four important classes of antibiotics (of the macrolide, sulfonamide, tetracycline and quinolone type) have been simultaneously preconcentrated with one set of HF-LPME conditions, followed by determination by ultra-HPLC combined with electrospray ionization tandem mass spectrometry (UHPLC-MS/MS). Antibiotics can be determined at ng L?1 levels using this highly sensitive and selective method. Parameters including immersion time, liquid membrane composition, sample pH, acceptor composition and extraction time were optimized to finally give detection limits in the 10?C250?ng?L?1 range. Good linearity was achieved, with up to 156 times enrichment over the four classes of antibiotics. This multi-residue method enabled the simultaneous enrichment of all 11 multi-class antibiotics from spiked river water samples, with relative recovery between 79 and 118%.
Figure
Carrier-mediated HF-LPME was utilized only one condition to simultaneously extract and enrich multi-class antibiotics in water with UHPLC-MS/MS detection providing high sensitivity and selectivity.  相似文献   
8.
A new method for the analysis of phenoxy acid herbicide residues in rice, based on the use of liquid extraction/partition and dispersive solid phase extraction (dispersive-SPE) followed by ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS), is reported. 5% (v/v) formic acid in acetonitrile as the extraction solvent and inclusion of citrate buffer helped partitioning of all the analytes into the acetonitrile phase. The extract was then cleaned up by dispersive-SPE using C18 and alumina neutral as selective sorbents. Further optimization of sample preparation and determination allowed recoveries of between 45 and 104% for all 13 phenoxy acid herbicides with RSD values lower than 13.3% at 5.0 μg kg−1 concentration level. Limit of detections (LODs) of 0.5 μg kg−1 or below were attained for all 13 phenoxy acids. Quantitative analysis was done in the multiple-reaction monitoring (MRM) mode using two combinations of selected precursor ion and product ion transition for each compound. This developed method produced relatively higher recoveries of the acid herbicides with a smaller range of variation and less susceptibility to matrix effects, than the original QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) method.  相似文献   
9.
We developed and evaluated a new method of low-pressure gas chromatography-tandem mass spectrometry (LP-GC/MS-MS) using a triple quadrupole instrument for fast analysis of 150 relevant pesticides in four representative fruits and vegetables. This LP-GC (vacuum outlet) approach entails coupling a 10 m, 0.53 mm i.d., 1 μm film analytical column between the MS transfer line and a 3 m, 0.15 mm i.d. capillary at the inlet. The MS creates a vacuum in the 10 m analytical column, which reduces the viscosity of the He carrier gas and thereby shifts the optimal flow rate to greater velocity. By taking advantage of the H(2)-like properties of He under vacuum, the short analytical column, a rapid oven temperature ramp rate, and the high selectivity and sensitivity of MS/MS, 150 pesticides were separated in <6.5 min. The 2.5 ms dwell time and 1 ms interscan delay of the MS/MS instrument were critical for achieving >8 data points across the 2-3 s wide peaks. To keep dwell and cycle times constant across all peaks, each segment consisted of 30 analytes (60 transitions). For assessment, we injected extracts of spiked broccoli, cantaloupe, lemon, and sweet potato from the updated QuEChERS sample preparation method. Average recoveries (n=72) were 70-120% for 144 of the pesticides, and reproducibilities were <20% RSD for all but 4 analytes. Also, detection limits were <5 ng/g for all but a few pesticides, depending on the matrix. In addition to high quality performance, the method gave excellent reliability and high sample throughput, including easy peak integration to obtain rapid results.  相似文献   
10.
The resolution (R(s)) of hydrophobic analytes in microemulsion EKC (MEEKC) and MEKC with suppressed electroosmosis was investigated using bisphenol-A-diglycidyl ether and its derivatives (BADGEs) as test analytes. Separation scales were compared using our equation for the resolution, R(s)= (square rootN/4)(alpha-1)/(1+K(2)),where k is the retention factor, alpha the selectivity (alpha = k(2)/k(1) for k(2) > or = k(1)>0), and N the average efficiency. At given concentrations of SDS and organic cosolvent in the buffer, in comparison with MEKC, MEEKC was found to provide better resolution of BADGEs, mainly due to the significantly smaller k in MEEKC, but not the greater alpha in MEEKC, while a comparable range of N. Significantly improved resolution of BADGEs was obtained with increase in the concentration of organic cosolvent in the MEEKC and MEKC buffers, while small change in R(s) with the SDS concentration in a range of 100-180 mM. In addition, a decrease in temperature or voltage resulted in slightly better R(s).  相似文献   
1 [2] 下一页 » 末  页»
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号