排序方式: 共有18条查询结果,搜索用时 15 毫秒
1.
在前文工作的基础上,结合MNDO/EHMO分子轨道方法和自然杂化轨道方法,具体计算了CC键和CP键的核自旋偶合常数.计算结果表明,1JCC和1JCP主要由成键原子的轨道杂化作用和键极性这两种结构因素所决定.为从简单价键理论角度解释和计算1JCC和1JCP值提供了简便直观的方法. 相似文献
2.
Ana P. F. M. de Urzedo Clésia C. Nascentes Maria E. R. Diniz Rodrigo R. Catharino Marcos N. Eberlin Rodinei Augusti 《Rapid communications in mass spectrometry : RCM》2007,21(12):1893-1899
The degradation of the dye Indigo Carmine by hypochlorite in aqueous solution was monitored by electrospray ionization mass spectrometry in the negative ion mode (ESI(—)‐MS). Hypochlorite was highly efficient in removing the color of aqueous solutions of the dye. ESI(—)‐MS monitoring showed that concomitant with the Indigo Carmine consumption two transient species appeared (detected as doubly charged anions) probably formed via a net insertion of two hydroxyl groups at the exocyclic C?C bond followed by the incorporation of two (mainly) or one oxygen atoms at the indolic rings of the dye. Structures of these products were proposed based on the ESI(—)‐MS/MS data and high accuracy mass measurements. These two transient intermediates quickly decomposed, both in the condensed and in the gas phase, to yield mono‐charged anions. Based on these results, a route for the Indigo Carmine degradation by hypochlorite in aqueous solution has been proposed. Copyright © 2007 John Wiley & Sons, Ltd. 相似文献
3.
Dalmázio I de Urzedo AP Alves TM Catharino RR Eberlin MN Nascentes CC Augusti R 《Journal of mass spectrometry : JMS》2007,42(10):1273-1278
The degradation of the dye indigo carmine in aqueous solution induced by two oxidative processes (H(2)O(2)/iodide and O(3)) was investigated. The reactions were monitored by electrospray ionization mass spectrometry in the negative ion mode, ESI(-)-MS, and the intermediates and oxidation products characterized by ESI(-)-MS/MS. Both oxidative systems showed to be highly efficient in removing the color of the dye aqueous solutions. In the ESI(-)-MS of the indigo carmine solution treated with H(2)O(2) and H(2)O(2)/iodide, the presence of the ions of m/z 210 (indigo carmine in its anionic form, 1), 216, 226, 235, and 244 was noticeable. The anion of m/z 235 was proposed to be the unprecedented hydroperoxide intermediate 2 formed in solution via an electrophilic attack by hydroxyl and hydroperoxyl radicals of the exocyclic C=C bond of 1. This intermediate was suggested to be rapidly converted into the anionic forms of 2,3-dioxo-1H-indole-5-sulfonic acid (3, m/z 226), 2-amino-alpha-oxo-5-sulfo-benzeneacetic acid (4, m/z 244), and 2-amino-5-sulfo-benzoic acid (5, m/z 216). In the ESI(-)-MS of the indigo carmine solution treated with O(3), two main anions were detected: m/z 216 (5) and 244 (4). Both products were proposed to be produced via an unstable ozonide intermediate. Other anions in this ESI(-) mass spectrum were attributed to be [4 - H + Na](-) of m/z 266, [4 - H](2-) of m/z 121.5, and [5 - H](2-) of m/z 107.5. ESI-MS/MS data were consistent with the proposed structures for the anionic products 2-5. 相似文献
4.
Flvia R. de Amorim Camilla Bof Milton B. Franco Jos Bento B. da Silva Clsia C. Nascentes 《Microchemical Journal》2006,82(2):168-173
In the present study, conventional and multivariate methods were used to optimize conditions for direct determination of aluminum in soft drinks by electrothermal atomic absorption spectrometry. For the conventional method, the optimized experimental parameters were: pyrolysis and atomization temperatures and chemical modifier. A multivariate study was performed using factorial design and the optimized parameters were the same employed in the univariate method including pyrolysis time. For the conventional method, the optimal conditions obtained were: pyrolysis temperature of 1600 °C, atomization temperature of 2700 °C, and Zr as permanent modifier. For the factorial design in the multivariate optimization, the Pareto´s chart showed that the atomization temperature, the modifier, and the pyrolysis temperature presented a significant effect on the integrated absorbance and the interaction between pyrolysis temperature and pyrolysis time also had a significant effect on the signal. Better results were obtained using Zr as modifier. The surface response indicates that the lowest pyrolysis (1100 °C) and atomization temperatures (2350 °C) provide higher absorbance for aluminum in soft drinks. Characteristic mass of 23.4 and 19.4 pg and LOD of 17.9 and 11.3 μg L− 1 was obtained to conventional and multivariate methods, respectively. The calibration was accomplished with standard addition in a range of 60–200 μg L− 1 for conventional method and of 38–200 μg L− 1for multivariate method with R higher than 0.99 for both conditions. Recoveries in both studies were nearly 100% with adequate precision for GFAAS analysis. For the Al concentrations level found in soft drinks, both experimental conditions are adequate as good results were obtained in recovery studies. The Al concentrations in different soft drinks range from 147.9 to 599.5 μg L−1. Higher concentrations were found in soft drinks sold in Al cans than in PET bottles, indicating that contamination can occur. 相似文献
5.
赵乃良 《高校应用数学学报(A辑)》1996,(1):91-96
Nira Dyn等提出的四点插值法是一种典型的自由曲线离散造型方法,但该方法不能控制插值点的切向。本文利用薄板样很可能 量的极小化原理给出了具有切向控制的四点分插值条件。用户可以方便地交互控制任一插值点的切向,使得四点插值法更为有效和实用。 相似文献
6.
Cloud point extraction for determination of cadmium in soft drinks by thermospray flame furnace atomic absorption spectrometry 总被引:3,自引:0,他引:3
Cloud point extraction (CPE) is proposed as a preconcentration procedure for the determination of Cd in soft drinks by thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS). The cadmium reacted with pyridyl-azo-naphthol (PAN) to form hydrophobic chelates, which were extracted into the micelles of Triton X-114 in a solution buffered at pH 9. NaCl was used for the phase separation. The variables which affect the preconcentration were optimized using a 23 factorial design and central composite design (CCD). A response surface maximum point was obtained, and the critical values were a concentration of 0.13 mmol L? 1 PAN, 0.03% m/v Triton X-114 and 2.3% m/v NaCl. Under the optimized conditions, after the extraction and preconcentration steps, a sample volume of 100 μL was introduced into the hot Ni tube using water as the carrier at a flow rate of 0.4 mL min? 1. The values obtained for the detection limit, relative standard deviation and preconcentration factor were 0.0178 μg L? 1, 4.1% (n = 8) and 55.5, respectively. The accuracy of the proposed method was demonstrated by performing addition-recovery experiments. Recoveries varied from 88 to 104%. 相似文献
7.
de Urzedo AP Diniz ME Nascentes CC Catharino RR Eberlin MN Augusti R 《Journal of mass spectrometry : JMS》2007,42(10):1319-1325
Photodegradation of the insecticide thiamethoxam (1), 3-[(2-chloro-5-thiazolyl)methyl]tetrahydro-5-methyl-N-nitro-4H-1,3,5-oxadiazin-4-imine, in an aqueous medium was monitored by electrospray ionization mass spectrometry in the positive ion mode, ESI(+)-MS. An aqueous solution of (1) was incessantly exposed to a UV radiation source and aliquots were taken after reaction times of 1, 2, 3, and 4 h. Analysis by GC/NCI-MS revealed that (1) was continuously degraded under these experimental conditions. However, the total organic carbon (TOC) content remained practically constant during the exposition period, thereby indicating that 1 was not mineralized but continuously converted into other compounds. ESI(+)-MS monitoring revealed that whereas the intensity of the ions of m/z 292/294 ([1 + H](+)) constantly decreased, there was the emergence of other ions of m/z 247/249, 197, 168, and 116 whose intensities simultaneously increased. Their structures were proposed on the basis of: (1) the data of their ESI(+)-MS/MS; (2) their high resolution m/z values; and (3) a plausible reactivity of the thiamethoxam molecule exposed to UV radiation in aqueous solution. Finally, these data allowed us to suggest a reaction route for the photodegradation of 1 in an aqueous medium. 相似文献
8.
Lopes RP de Urzedo AP Nascentes CC Augusti R 《Rapid communications in mass spectrometry : RCM》2008,22(22):3472-3480
The degradation of thiamethoxam (1) and imidacloprid (2), prototype neonicotinoid insecticides bearing a characteristic N-NO2 moiety in their structures, promoted by a number of zero-valent metals (Fe, Sn, Zn) upon ultrasonic irradiation in acidic aqueous solution (pH 2) was investigated. It was verified that thiamethoxam (1) and imidacloprid (2) are quickly and almost completely consumed under these experimental conditions (degradation >90% after a reaction time of 30 min) and that ultrasonic irradiation strongly enhances the degradation rate for both insecticides, especially when zinc and tin are employed. Based on the results from electrospray ionization mass (and tandem mass) spectrometry in the positive ion mode, degradation routes for both insecticides, comprising an initial NO2 --> NH2 reduction, were proposed. In addition, products from the dehydrochlorination of imidacloprid were also found to be formed under these conditions. 相似文献
9.
Cloud point formation based on mixed micelles in the presence of electrolytes for cobalt extraction and preconcentration 总被引:1,自引:0,他引:1
A new micelle-mediated phase separation of metal ions, applied for preconcentrating trace levels of cobalt as a prior step to its determination by flame atomic spectroscopy, has been developed. Two methods were proposed employing both Triton X-100 and sodium dodecyl sulfate (SDS) as a mixed micellar system while the phase separation was induced by HCl or NaCl addition. Cobalt was complexed with pyridylazo compounds (PAN, PAR, 5-Br-PADAP) in an aqueous surfactant medium and it was concentrated in the surfactant rich phase after phase separation. The chemical variables affecting the cloud point extraction were evaluated, optimized and successfully applied to cobalt determination in pharmaceutical samples. Under the optimized conditions, the preconcentration system permitted limits of detection as 1.1 and 1.6 μg l−1 cobalt, respectively, when HCl and NaCl were used. Both proposed methods showed linear calibration within a 25-200 μg l−1 cobalt range. The extraction efficiency was investigated at different cobalt concentrations (40-185 μg l−1) and good recoveries (98-102%) were obtained by using NaCl as electrolyte. The results obtained were compared with those observed with ET AAS. 相似文献
10.
George L. Donati Joaquim A. Nóbrega Clésia C. Nascentes Bradley T. Jones 《Microchemical Journal》2009,93(2):242-246
The spectroscopic determination of iodide is a difficult challenge, especially in small sample volumes. The strongest transition lines for this element lie in the vacuum ultraviolet region of the spectrum, so most conventional instruments produce very weak signals. This work describes a tungsten coil atomic emission procedure for the indirect determination of iodide. A 25 μl aliquot of a solution containing a known amount of indium is deposited on the tungsten coil and dried with a simple heating program. Once the coil is dry, 25 μl of an iodide solution is added to the coil. The solution is dried and vaporized at high current. The atomic emission signal for In at 451.1 nm is monitored. In the presence of iodide, InI is formed and the In emission signal is attenuated. This attenuation is proportional to iodide concentration with a method detection limit of 0.6 mg l− 1 iodide using an In concentration of 10 mg l− 1, and 3 mg l− 1 iodide using an In concentration of 50 mg l− 1. Linear calibration curves span a range of two orders of magnitude. Analysis of a deionized water sample spiked with 50 mg l− 1 iodide gives a recovery of 100% and a precision of 5.5% relative standard deviation. Analysis of a tap water sample spiked with 50 mg l− 1 iodide gives a recovery of 140% and a precision of 7.1% relative standard deviation. The poor accuracy for the tap water analysis may arise from the reaction of In with other halides in the sample. This is the first report of determination of a halogen using the tungsten coil atomizer. 相似文献